• Do not expose the charge controller to direct sunlight to avoid power losses due to
overheating.
4.2.4 Safety Clearance
Observe the following safety clearance to wall, other devices or objects to ensure
sufficient heat dissipation.
Direction
Safety clearance
Sides
8in or 20cm
Top
12in or 30cm
Bottom
8in or 20cm
5.
MPPT Controller Connection
5.1 Safety
Danger!
High voltages are present and dangerous
• Disconnect the PV array using a disconnection unit and secure it against
accidental reactivation.
• Disconnect the circuit breaker and ensure that it cannot be reconnected.
• Ensure that no voltage is present in the system.
Warning:
Risk of injury due to electric shock
。
If all cables with different voltages are routed in parallel, damaged cable
insulations may lead to a short circuit.
• Route all cables separately if possible.
Warning:
Over voltage can destroy the system.
• Use an external over voltage protector in areas with an increased risk of
lightning.