5.2

 

Power Connector

 

5.2.1

 

Receptacle Specification

 

 

5.2.2

 

Pin Assignment

 

 

 

 

5.2.3

 

Power Cable Recommendation

 

 

 

 

Description

Manufacturer

Structure

Jacket Shield

AWG

Dacar 676

Leoni

2x0,14mm

2

yes

yes

 AWG26

Dacar 645

Leoni

2x0,17mm

2

yes

yes

 AWG25

Dacar 646

Leoni

2x0,35mm

2

yes

yes

 AWG22

FL09YBCY

Kromberg & Schubert 2x0,14mm

2

yes

yes

AWG26

FLCUSN9Y-9YBCY

Kromberg & Schubert 2x0,13mm

2

yes

yes

AWG26

Dacar 547

Leoni

2x0,13mm

2

yes

no

 AWG26

Dacar 626

Leoni

2x0,14mm

2

yes

no

 AWG26

Dacar 546

Leoni

2x0,35mm

2

yes

no

 AWG22

Dacar 624

Leoni

2x0,35mm

2

no

no

 AWG22

Dacar 617

Leoni

2x0,17mm

2

no

no

 AWG25

FLR9Y-31Y

Kromberg & Schubert 2x0,35mm

2

yes

no

 AWG22

FLKCuMgU9Y-9Y

Kromberg & Schubert 2x0,13mm

2

yes

no

 AWG26

FLCUSNU9Y-31Y

Kromberg & Schubert 2x0,13mm

2

yes

no

 AWG26

100BASE-T1

1000BASE-T1

Description

Vendor

Part Number Distributor Distributor Number

Connector

MINI50 2Pos Receptacle Opt A

Molex

347910020

Digi-Key

WM16033-ND

CTX50 Terminal L-Grip 22 AWG

Molex

5600230448

Digi-Key

WM16315CT-ND

CTX50 Terminal M-Grip 24 AWG

Molex

5600230421

Digi-Key

WM8745CT-ND

CTX50 Terminal S-Grip 26-30 AWG

Molex

5600230444

Digi-Key

WM25289CT-ND

Terminals

Description

Manufacturer

Structure

Jacket Shield Remarks

FLRY 2x0,35-B RD/BL

Leoni

2x0,35mm

2

no

no

 AWG22

FLRY-B 1x0,35 RD

Leoni

1x0,35mm

2

no

no

 AWG22

FLRY-B 1x0,35 BL

Leoni

1x0,35mm

2

no

no

 AWG22

Power

Supply

Pin

Signal

Remark

1

PWR (+)

5V - 28V DC

2

GND (-)

Summary of Contents for Auto-Link-SPE-G

Page 1: ...User Manual Auto Link SPE G 1000BASE T1 Media Converter INO_Auto Link SPE G_User_Manual_V1 6 docx ...

Page 2: ...Connector 5 5 2 1 Receptacle Specification 5 5 2 2 Pin Assignment 5 5 2 3 Power Cable Recommendation 5 6 Configuration 6 6 1 T1 Role DIP1 6 6 2 Auto Role Switch DIP2 6 6 3 Auto Negotiation DIP3 6 6 4 Speed DIP4 7 6 5 1000BASE T 100BASE TX Link 7 7 Software 7 7 1 Controller Functions 8 7 2 T1 Functions 8 Link Monitoring 8 Cable Diagnostics 8 Register Access 9 7 3 T X Functions 9 8 Important Informa...

Page 3: ...equipped with a dual power supply that seamlessly switches between the dedicated power port and USB 2 Technical Data 2 1 Features Standards IEEE802 3bp IEEE802 3bw IEEE802 3ab IEEE802 3u 1000BASE T1 100BASE T1 Port Molex Mini50 4pos 1000BASE T 100BASE TX Port RJ45 USB C Port Configuration Firmware Update DIP Switch for Master Slave Speed Auto Negotiation Setting Automatic Master Slave Detection pr...

Page 4: ...Cables 5 1 1000BASE T1 100BASE T1 Connector 5 1 1 Receptacle Specification 5 1 2 Pin Assignment 5 1 3 T1 Cable Recommendation For proper operation of the link the used network cables and connectors for the T1 link must comply to the specifications of the respective standards Please refer to 100BASE T1 IEEE 802 3bw Clause 96 7 1000BASE T1 IEEE 802 3bp Clause 97 6 Description Vendor Part Number Dist...

Page 5: ...i 2x0 17mm2 no no AWG25 FLR9Y 31Y Kromberg Schubert 2x0 35mm2 yes no AWG22 FLKCuMgU9Y 9Y Kromberg Schubert 2x0 13mm2 yes no AWG26 FLCUSNU9Y 31Y Kromberg Schubert 2x0 13mm2 yes no AWG26 100BASE T1 1000BASE T1 Description Vendor Part Number Distributor Distributor Number Connector MINI50 2Pos Receptacle Opt A Molex 347910020 Digi Key WM16033 ND CTX50 Terminal L Grip 22 AWG Molex 5600230448 Digi Key ...

Page 6: ...Role Switch feature can increase the link setup time Do not connect the T1 interfaces of two Auto Link SPE G with activated Auto Role Switch on both sides This may prevent the link establishment 6 3 Auto Negotiation DIP3 DIP3 turns the 802 3bp Auto Negotiation feature on and off When enabled T1 link role Master Slave and the link speed 1000 100Mbit s are automatically negotiated between the link p...

Page 7: ...ablished with 1000Mbit s the Auto Link SPE G advertises 1000Mbit s and if the T1 link is established with 100Mbit s the Auto Link SPE G advertises 100Mbit s 7 Software The graphical user interface is intended for remote monitoring It can also be used for testing and development purposes since it provides direct access to the register sets of the integrated PHYs It provides the following functions ...

Page 8: ...ions Link Monitoring The UI provides continuous monitoring of T1 link state and SQI Signal Quality Indicator Using the checkboxes you can enable and disable the respective functions The bars of the SQI bar graph represent the exact SQI values ranging from SQI 0 to SQI 7 SQI needs to be 1 or higher for proper operation of the link Cable Diagnostics Using the T1 PHY Automotive Cable Diagnostics cabl...

Page 9: ...R or TAB will read the respective register Value Represents a PHY register value that has been read entering the address data in the Device and Register fields Entering a value in this field will result in a write operation to the respective register Written values are read back and displayed for a validation of the write operation All entries are expected to be hexadecimal numbers 7 3 T X Functio...

Page 10: ...oHS Restriction of the use of certain hazardous substances dt Restriction of use certain dangerous substances 8 3 CE Marking The i novative Auto Link SPE G has the CE mark This device complies with the requirements of EU Directive 89 336 EC Directive on electromagnetic compatibility and the mutual recognition of their conformity Conformity with the o a directive is confirmed by the CE mark 9 Manuf...

Reviews: