User Manual
BOP HD8 / BOP HD16
Ref.: IR1212828 A 21.08.2009
Edition 1.0
Page 60/87
I + M E A C T I A G m b H
An alarm state can be signalled by a Relay.
0
No Alarm signalisation by Relay
1 ... 4 The configured relay signals the Alarm
6.4.8.3
A
LARM SIGNALING
Relay 2 is closed while recording by default. With this setting the “while recording relay”
can also be configured to show an alarm state
0
Relay 2 is closed while recording and do not show an alarm state
1
Relay 2 is closed while recording and flashes at alarm state. This setting
is useful if only 1 Relay should be used
6.4.9.
IBIS
BOP HD can be connected to the IBIS-BUS by using the BOP HD IBIS interface.
Please ask your specialist dealer or I+ME ACTIA for further information.
6.4.9.1
IBIS
TIME ADJUSTMENT
This setting activates the time synchronisation to the IBIS-BUS time.
0
IBIS Time Adjustment not active
1
BOP HD does a synchronisation of the real time clock to the IBIS-BUS.
The system time will be set after a restart.