4
Z -RANGE INSTALLATION MANUAL
Contents of the Box
Inside each box is the 5.14 kWh battery (51.2 V
nom
, 100 A capacity), negative and a positive DC
cable with amphenol connectors (battery side) and M8 lugs (inverter / DC busbar side). Each
box also contains a pin-to-pin CAT cable for communication to either the inverter or between
the battery units.
Handling the Battery
Work on the battery should be carried out by qualified personnel only.
Please use the provided handles to lift and move the battery. Please handle the battery with
care as the battery is sensitive to mechanical shock.
Ports used During Operation of the
Battery
Figure 1 shows the ports that are used during the operation of the battery. Please pay close
attention to which ports are used and connected during operation. The Figure should be read
in conjunction with Table 1.
Table 1: Ports and switches used during operation of the Z-Range
No
Instructions
No
Instructions
1
Negative DC post #1
9
Address dial switch
2
Negative DC post #2
10
RS232 port
3
On/ Off switch
11
Link B
4
SOC indicator
12
Link A
5
Alarm indicator
13
Reset button
6
Run indicator
14
CAN/RS485 port
7
Dry contact
15
Positive DC post #1
8
GND
16
Positive DC post #2
Figure 1: Z-Range Battery Module