I-CON COBALT Pro 101674 Installation Instructions Manual Download Page 3

COBALT Pro

 Wall Sensor Retrofit Kit for

Concealed Flush Valve Installation Instructions

I-CON Systems, Inc., for product support call 1-866-730-7192 or visit us online at support.i-con.com

One or more products contained herein are protected by U.S. Patent with other undergoing the patent process www.i-con.com/patents

Part No. 101674

page 3

Rev 080323

ProLAST

®

 T-SEAL & FLUSH VALVE CAP 

ASSEMBLY INSTALLATION

Step 1

Insert ProLAST® T-Seal into flush valve body.

Step 2

Place square-profile O-ring into groove on bottom of flush valve 

cap assembly. Place flush valve cap assembly onto flush valve 

body.

Step 3

Tighten locking ring by hand to flush valve body.

WALL SENSOR INSTALLATION - INSTALLATION 

WITH ELECTRICAL BOX

Step 1

Loosen set screw on plate. Remove cover by pulling out, then up.

Step 2

Feed control module cable through junction box knock-out. 

 

Attach control module to junction box with provided screws.

Summary of Contents for COBALT Pro 101674

Page 1: ...mercial manufactured products are made of first class materials are free from defects and are made to withstand normal use when installed properly Products have the following warranty periods 3 years...

Page 2: ...box 4 x 4 x 2 1 2 The location will vary based on the rough in Refer to the rough in drawings for specific mounting location Use a GFCI plaster ring 4X4 JUNCTION BOX GFCI PLASTER RING I CON IR PLATE A...

Page 3: ...ProLAST T SEAL FLUSH VALVE CAP ASSEMBLY INSTALLATION Step 1 Insert ProLAST T Seal into flush valve body Step 2 Place square profile O ring into groove on bottom of flush valve cap assembly Place flush...

Page 4: ...ttach and secure cover with set screw WALL SENSOR INSTALLATION INSTALLATION WITHOUT ELECTRICAL BOX Step 1 Drill 1 1 2 hole through wall The location will vary based on the existing flush valve install...

Page 5: ...e through 1 1 2 opening Attach control module to wall with provided screws Step 5 Reattach and secure face plate with set screw INTERFACE MODULE INSTALLATION Step 1 Open interface module Mount to flat...

Page 6: ...sh valve after each adjustment The proper flow rate should completely cleanse fixture without splashing water outside of fixture NOTE The flow from the valve must never exceed the flow capacity of the...

Page 7: ...ion button Current profile number is displayed through LED illuminations and the digital display To change profile press and release profile quick action button again Continue to press and release pro...

Page 8: ...ser The range can be adjusted from 6 54 inches Exit adjusts the amount of time an object must not be detected before the valve considers the user to have exited The range can be adjusted from 0 15 sec...

Reviews: