I-CON Systems, Inc., for product support call 1-866-730-7192 or visit us online at support.i-con.com

One or more products contained herein are protected by U.S. Patent with other undergoing the patent process www.i-con.com/patents

Part No. 101674

Flat Head Screwdriver

Phillips Screwdriver

T15H Screwdriver

Smooth Jaw 

Wrench

page 1

Rev 080323

• Sensor Cap Assembly
• ProLAST® T-Seal
• Actuator Opening Cover
• Wall Sensor
• Power & Interface Module

KIT INCLUDES

TOOLS NEEDED

Strap Wrench

• All plumbing should be installed according to applicable state 

and local codes and regulations. 

• Before installation of the I-CON flush valve, ensure the water 

closet or urinal fixture, drain line and water supply line are 

properly installed. 

• Water supply lines must be sized to allow for appropriate 

water flow for each fixture. 

• Flush all water supply lines of any debris before making 

connections. 

• Do not use pipe sealant or plumbing grease on any 

components or couplings, with the exception of the control stop 

inlet.

• A smooth jaw or strap wrench should be used for installation 

to prevent damage to the finish of the I-CON flush valve and 

components. 

The I-CON flush valve is designed to operate at water pressures 

ranging from 15 to 100psi (103 to 689kPa). The fixture type 

determines the minimum pressure required for the valve. 

Most low-consumption water closets are designed to operate 

with a minimum flowing water pressure of 25psi (172kPa). 

Many building codes and the ASME A112.19.2 standard state 

maximum static water pressure as 80 psi. 

I-CON Systems, Inc. (I-CON) warrants that its commercial 

manufactured products are made of first-class materials, are 

free from defects, and are made to withstand normal use when 

installed properly. Products have the following warranty periods: 

3 years for COBALT®, COBALT Pro™, and COBALT Connect™ 

faucets and flush valves and I-CON EDGE® gateways. 1 year for 

all other products and decorative finishes. The warranty period 

begins on the date of purchase. 
Products should be sent to I-CON at the customer’s expense. 

I-CON will take a reasonable amount of time to determine 

if the product is defective and whether it will be repaired or 

replaced. During the warranty period, items will either be 

(1) repaired at no charge using new replacement parts or (2) 

replaced with either a new similar product or one manufactured 

from new or serviceable used parts that are, at minimum, a 

functional equivalent to the original. The course of action will 

be determined at I-CON’s discretion. Replacement products that 

are installed according to the instructions provided by I-CON 

will assume the remaining warranty of the original product. The 

limited warranty is only applicable to the product’s materials 

and workmanship. No claims for labor, transportation, or other 

incidental or consequential costs will be allowed. No extended 

warranties are available. THE SOLE AND EXCLUSIVE REMEDY 

FOR ANY DEFECTIVE PRODUCT IS LIMITED TO REPAIRING OR 

REPLACING THE DEFECTIVE PRODUCT. Before installing and 

using products, the purchaser is responsible for determining the 

products’ suitability and assumes all risks and liabilities related 

to the product. 
This warranty only applies to persons and organizations that 

purchase I-CON products directly from I-CON or an authorized 

I-CON representative for the purpose of resale. This warranty 

does not apply to the life of batteries or other consumables.

PRIOR TO INSTALLATION

LIMITED WARRANTY

Summary of Contents for COBALT Pro 101674

Page 1: ...mercial manufactured products are made of first class materials are free from defects and are made to withstand normal use when installed properly Products have the following warranty periods 3 years...

Page 2: ...box 4 x 4 x 2 1 2 The location will vary based on the rough in Refer to the rough in drawings for specific mounting location Use a GFCI plaster ring 4X4 JUNCTION BOX GFCI PLASTER RING I CON IR PLATE A...

Page 3: ...ProLAST T SEAL FLUSH VALVE CAP ASSEMBLY INSTALLATION Step 1 Insert ProLAST T Seal into flush valve body Step 2 Place square profile O ring into groove on bottom of flush valve cap assembly Place flush...

Page 4: ...ttach and secure cover with set screw WALL SENSOR INSTALLATION INSTALLATION WITHOUT ELECTRICAL BOX Step 1 Drill 1 1 2 hole through wall The location will vary based on the existing flush valve install...

Page 5: ...e through 1 1 2 opening Attach control module to wall with provided screws Step 5 Reattach and secure face plate with set screw INTERFACE MODULE INSTALLATION Step 1 Open interface module Mount to flat...

Page 6: ...sh valve after each adjustment The proper flow rate should completely cleanse fixture without splashing water outside of fixture NOTE The flow from the valve must never exceed the flow capacity of the...

Page 7: ...ion button Current profile number is displayed through LED illuminations and the digital display To change profile press and release profile quick action button again Continue to press and release pro...

Page 8: ...ser The range can be adjusted from 6 54 inches Exit adjusts the amount of time an object must not be detected before the valve considers the user to have exited The range can be adjusted from 0 15 sec...