SERVICE MANUAL
TVL-151M / 201M
----------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------
16
3-3. Inspection specification of ASSY-CONTROL
Inspection procedure
standard
Remark
1
Turn off the power of JIG ( check the power of JIG )
2
Connect 7P Connector with JIG
3
Check the tight insertion of TACT SW
Tight insertion
4
Turn on the power of JIG.
5
Check the color of LED is red
STAND BY : RED LED
6
Press POWER KEY , and then check the screen is displaying & LED is lighting in green .
POWER ON : GREEN LED
7
Press each KEY and check the function
CHECK key SW
8
With REMOTECON , turn off the power
Check REF LED
9
Turn off the power of the JIG
10 Disconnect the Connector
RMK
1) After checking the connecting status of 15PIN in JIG , go on the inspection
: in case of no sign , KEY may not work .