18-2-2 Alternator system
Failure
Cause
Remedy
18-3
Cannot be charged.
- Cords between terminals are
disconnected or connectors are in
loose connection.
- Improper earth conection
- Brush and slip ring do not contact.
- Coil is disconnected or burnt.
- Diode is damaged.
- Loose connection of cords
between each terminal
- Fan belt slips.
- Improper contact or insufficient
movement of brush and slip ring
- Short-circuit of coil
- Defective diode
- Defective alternator
- Wrong installation
- Defective fan belt
- Defective bearing
- Diodes on (+) and (-) sides broke
down.
- Capacitor broke down.
- Alternator internal short-circuited
Insufficient charge
Reconnect cord-tighten
connections.
Make good earth conections.
Connect or replace
Replace
Replace
Tighten connections.
Adjust.
Clean slip ring and brush holder.
Replace
Replace
Replace
Connect.
Replace.
Replace.
Replace.
Overcharge
Noise
Fuse melts.
Summary of Contents for Robex 22-7
Page 1: ...SERVICE MANUAL SER NO HY2270001...
Page 2: ......
Page 4: ......
Page 8: ...2 1 Location of Serial Number 2 1...
Page 24: ......
Page 32: ......
Page 42: ...5 5 Throttle valve Hydraulic pressure tester OUT IN OPEN CLOSE...
Page 44: ......
Page 46: ...6 1 Installation 6 1 J S Left J S J S Right J S...
Page 50: ......
Page 59: ...8 JOYSTICK PILOT VALVE CONTENTS 8 1 Specification 8 2 Structure...
Page 67: ......
Page 73: ......
Page 83: ......
Page 96: ...15 IDLER CONTENTS 15 1 Standard of maintenance 15 1 1 Idler...
Page 101: ......
Page 102: ...17 TRACK ROLLER CONTENTS 17 1 Standard of maintenance 17 1 1 Track roller...