08

6. ERROR MESSAGES

Warning Code on 

Digital Display

Reason(s)

Solution(s)

E01 (also with

continuous

buzzer sound)

High temperature alarming

After the internal temperature of charger reduces, the 

charger will automatically start charging again

E02

1) Open-circuit 

2) Dirty Battery Posts

3) Dead Battery 

4) Output Short Circuit

1) Connect the red and black clamps or ring terminals 

to the battery posts

2) Clean the battery posts

3) Replace the battery with a new one immediately

4) Disconnect red and black output terminals

E03 (also with 

intermittent 

buzzer sound)

Charge mode is

 inappropriate (choose 12V 

Mode for 24V battery)

Choose appropriate 24V Mode for

your 24V battery.

E04

Battery cannot store electric

charge during charging

process

Replace the battery with a new one

E05

Unsuccessful desulphation

Replace the battery with a new one

E06

Reverse connection

Connect to the correct polarities

Summary of Contents for HYBC-20

Page 1: ...MANUAL HYBC 20 Please read and understand all important safety and operating instructions before using this charger In addition please read and follow all battery and vehicle manufacturer s instructi...

Page 2: ...ttery charger therefore some parts of this battery charger may be changed in order to achieve the better quality but the main functions and operations will not be alternated and changed Your understan...

Page 3: ...HYUNDAI 01 Table of Contents SAFETY CONNECTING TO THE BATTERY ABOUT HYBC 20 CHARGING MODES CHARGING STEPS ERROR MESSAGES 2 3 4 5 7 8...

Page 4: ...s 9 When it is necessary to remove a battery from vehicle to charge always remove grounded terminal from battery first Make sure all accessories in the vehicle are off in order to prevent an arc 10 It...

Page 5: ...ctions to the carburetor fuel lines or thin metal parts 3 Identify if you have a negative or positive grounded vehicle This can be done by identifying which battery post NEG or POS is connected to the...

Page 6: ...ARGING LED is on it is on charging when the CHARGING LED is off and FULL LED is on the charging is completed But do NOT break the connection immediately It will automatically switches from full charge...

Page 7: ...2V 6A 06A Keep on Connected to 12V battery it can turn into 6A by pressing CURRENT button This mode is recommend for 10 180AH batteries 12V 8A 08A Keep on Connected to 12V battery it can turn into 8A...

Page 8: ...ur are ready to start your vehicle whether FULL LED is illuminated or not After each boost the charger has mandatory 5 minute rest for safety reason even you press the boost button again the charger w...

Page 9: ...nt STEP 5 BULK Charge with constant maximum current until battery voltage is reached to the threshold STEP 6 ABSORPTION Provide gradually declining current charge for maximum battery voltage STEP 7 AN...

Page 10: ...d black clamps or ring terminals to the battery posts 2 Clean the battery posts 3 Replace the battery with a new one immediately 4 Disconnect red and black output terminals E03 also with intermittent...

Page 11: ...DEL HYBC 20 Satisfies the requirements of the Council Directives EMC directive 2014 30 EU Low Voltage Directive 2014 35 EU RoHS Directive 2011 65 EU RoHS Directive 2015 863 EU and conform with the nor...

Page 12: ...HYUNDAI Corporation 25 Yulgok ro 2 gil Jongno gu Seoul 03143 Korea Post Code 03143 82 2 390 1114 www hyundaicorp com Copyright HYUNDAI Corporation All rights reserved Made in P R C...