background image

19 

 

 

 

12.0   

POSTAL ADDRESS 

 

 

 

Genpower Ltd, Isaac Way, 

 

 

 

 

 

 

 

 

 

London Road, Pembroke Dock, 

 

 

 

 

 

 

 

 

 

Pembrokeshire. 

 

 

 

 

 

 

 

 

 

SA72 4RW. UK. 

12.1   

TELEPHONE 

 

 

 

 

+44 (0) 1646 687880 

12.2   

FAX   

 

 

 

 

 

+44 (0) 1646 686198 

12.3   

SUPPORT   

 

 

 

 

[email protected]

 

12.4   

WEBSITE 

 

 

 

 

 

www.hyundaipowerequipment.co.uk 

 

 

 

13.0   

To register your machine for the Manufacturer’s Warranty, please visit: 

 

 

https://hyundaipowerequipment.co.uk/warranty

 

13.1   

For full Warranty Terms & Conditions, please visit: 

 

 

https://hyundaipowerequipment.co.uk/support/warranty-information 

 

 
 
 
14.0   

Our manuals are constantly being reviewed and updated. 

 

 

However if you find an error, omission or something you find unclear, please 

 

 

contact your dealer for assistance.

 

14.1   

Our latest manuals are also placed online. 

14.2   

We reserve the right to make any modifications without prior notice whenever 

 

 

necessary. 

 

 

 

 

 

 

 

 

 

 

 

       12. CONTACT DETAILS 

       13. WARRANTY 

       14. MANUAL UPDATES 

Summary of Contents for HY70100P

Page 1: ...1...

Page 2: ...ATION 9 4 STARTING PROCEDURE 10 5 STOPPING PROCEDURE 11 6 USING THE MACHINE 11 7 MAINTENANCE 11 14 8 SPECIFICATION 15 9 TROUBLESHOOTING 16 10 RECYCLING AND PRODUCT DISPOSAL 17 11 DECLARATION OF CONFOR...

Page 3: ...following warning signs symbols and or PPE pictograms may ap pear throughout this manual You MUST adhere to their warnings Failure to doso may result in personal injury to yourself or those around yo...

Page 4: ...e 1 14 To avoid carbon monoxide poisoning DO NOT use Petrol Diesel powered equipment inside any of the following Home garage tent camper van mobile home caravan or boat This is not exhaustive and if y...

Page 5: ...are but not limited to safety gloves overalls 1 33 When fueling de fueling ALWAYS avoid inhaling fumes 1 34 When de fueling ALWAYS use a proper fuel retriever 1 35 ALWAYS carry fuel in the correct an...

Page 6: ...o another part of your face or body 1 59 Gasses from charging batteries are highly flammable and great care should be taken to charge in well ventilated areas 1 59 1 There is an explosion risk if the...

Page 7: ...and condition before use If in any doubt do not use the compressor and contact your service agent 2 3 Before moving or maintaining the compressor ensure that the air tank pressure has been vented 2 4...

Page 8: ...t the compressor is adequately protected 2 24 DO NOT smoke or have any naked flames nearby whilst refuelling 2 25 DO NOT leave the compressor unattended 2 26 DO NOT remove the fuel cap or try to refue...

Page 9: ...pressor moves whilst in operation 3 5 If the surface is in a raised position make sure the compressor cannot fall securing it in a suitable way 3 6 To ensure good ventilation and efficient cooling the...

Page 10: ...nap back gently return it 4 4 Once running move the choke to the OFF position 4 5 When the engine is running smoothly the compressor will operate automatically building up the pressure in the tank whi...

Page 11: ...mulate in the tank as this will corrode the inside of the tank and affect the pressure rating of the tank WARNING Service and maintenance must be performed by an authorised agent DO NOT tamper with or...

Page 12: ...e frequently in dusty environments 7 10 Remove the air filter element by undoing the screw and removing the filter cover 7 11 Clean the air filter by blowing through from the clean side with an airlin...

Page 13: ...00 hours 7 19 Change the air filter element 7 20 Replace the pump lubricating oil with an oil suitable for temperatures ranging from 5 C to 45 C viscosity Type 68 compressor oil 7 21 Drain the oil whe...

Page 14: ...nk Check for oil leaks Check oil levels Check guards and covers Check for noise and vibrations Check for air leaks Clean compressor Clean air filters Check safety release valve Check belt tension Chan...

Page 15: ...97 Engine Speed rpm 1800 idle Pump Speed rpm 950 Start Method Recoil Maximum Pressure psi bar 145 10 Cut Out Pressure psi bar 87 6 Tank Capacity l 90 Air Displacement free air delivery cfm l min 10 7...

Page 16: ...r is at idle speed Non return valve seal defective Discharge air tank pressure If problem persists contact your dealer Compressor does not stop at maximum pressure Pressure switch fault Contact your d...

Page 17: ...ycling centre 10 4 Certain products contain batteries which should not be disposed of in your domestic waste 10 5 You MUST recycle batteries in accordance with your local authority or recycling centre...

Page 18: ...Type Serial No Petrol Air Compressor Net Installed Power 4 4kW The technical document is kept by Roland Llewellin Genpower Ltd Isaac Way Pembroke Dock Pembrokeshire SA72 4RW The conformity assessment...

Page 19: ...https hyundaipowerequipment co uk warranty 13 1 For full Warranty Terms Conditions please visit https hyundaipowerequipment co uk support warranty information 14 0 Our manuals are constantly being rev...

Page 20: ...20...