background image

12 

 

 

 

6.0 

Turn the power switch to the OFF position. 

6.1 

Unplug the compressor. 

6.2 

Reduce the pressure in the air tank through the air supply hose. 

 

 

 

7.0 

To determine the correct working pressure and air flow requirements for any piece 
of equipment, check the corresponding manual. 

7.1 

Be aware that the air flow figure stated on tools and accessories refers to ‘free air 
delivery’ and not the piston displacement of the compressor. 

7.2 

When adjusting the regulator, always adjust up to the required pressure. 

7.3 

After fitting the desired coupling to the outlet valve, connect an air hose and hook up 
to an air system 
An outlet regulator is necessary to use air equipment direct from the compressor. 

7.4 

At the end of each working day, drain any moisture from the main tank. 

7.5 

Place a container under the drain plug and then carefully unscrew it anti-clockwise. 

7.6 

DO NOT allow moisture to accumulate in the tank as this will corrode the inside of 
the tank and affect the pressure rating of the tank. 

 

 

 

 

 

 

 

 

WARNING

 

 

 

Service and maintenance must be performed by an authorised agent. 

 

 

DO NOT tamper with, or attempt to adjust the pressure switch or safety valve. 

 

 

Before moving or carrying out any maintenance on the compressor, make sure that 

 

 

the ignition switch is OFF and the air tank pressure has been vented and the  

 

 

compressor allowed to cool down for a period of time.

 

 

 

 

8.0 

 

You should drain the tank at the end of each day. 

8.1 

 

Place a suitable container capable of holding water, underneath the compressor. 

        6. STOPPING PROCEDURE 

        7. USING THE MACHINE 

        8. MAINTENANCE 

        DRAINING THE AIR TANK 

Summary of Contents for HY30100V

Page 1: ...1...

Page 2: ...4 PREPERATION 10 5 STARTING PROCEDURE 11 6 STOPPING PROCEDURE 11 7 USING THE MACHINE 11 8 MAINTENANCE 12 13 9 TROUBLESHOOTING 14 10 TROUBLE SHOOTING 29 11 STORAGE TRANSPORTATION 29 12 RECYCLING AND PR...

Page 3: ...following warning signs symbols and or PPE pictograms may ap pear throughout this manual You MUST adhere to their warnings Failure to doso may result in personal injury to yourself or those around yo...

Page 4: ...e 1 14 To avoid carbon monoxide poisoning DO NOT use Petrol Diesel powered equipment inside any of the following Home garage tent camper van mobile home caravan or boat This is not exhaustive and if y...

Page 5: ...are but not limited to safety gloves overalls 1 33 When fueling de fueling ALWAYS avoid inhaling fumes 1 34 When de fueling ALWAYS use a proper fuel retriever 1 35 ALWAYS carry fuel in the correct an...

Page 6: ...o another part of your face or body 1 59 Gasses from charging batteries are highly flammable and great care should be taken to charge in well ventilated areas 1 59 1 There is an explosion risk if the...

Page 7: ...tion before use If in any doubt do not use the compressor and contact your service agent 2 3 Before moving or maintaining the compressor ensure that the air tank pressure has been vented 2 4 Only use...

Page 8: ...vibration or heat DO NOT allow contact with abrasive or corrosive materials YOU MUST drain condensation from the tank daily and inspect side walls for corrosion every 12 months 2 25 The compressor is...

Page 9: ...nd If damaged contact your dealer 3 0 Attach both air filters to the top of the motor heads by screwing in to place 3 1 Attach the wheel kit by sliding the washer onto the axle bolt 3 2 Pass the bolt...

Page 10: ...pressor moves whilst in operation 4 5 If the surface is in a raised position make sure the compressor cannot fall securing it in a suitable way 4 6 Remove the transit plug from the oil hole and replac...

Page 11: ...f the compressor is not working properly the pressure gauge will indicate that there is a decrease in pressure in the air tank If there is an air leak from the compressor the pressure in the air tank...

Page 12: ...pressor 7 4 At the end of each working day drain any moisture from the main tank 7 5 Place a container under the drain plug and then carefully unscrew it anti clockwise 7 6 DO NOT allow moisture to ac...

Page 13: ...from the inside out You can use a low pressure airline to do this 8 10 Reinstall the air filter 8 11 A small leak in any hose or connection will reduce the air compressors performance 8 12 To test fo...

Page 14: ...ce dealer The motor does not start or starts slowly Low voltage supply to the motor Check that the main voltage corresponds to the air compressors specification An extension cord that is under rated o...

Page 15: ...0100V Power kW HP 2 2 3 2 2 3 Displacement L min 396 396 CFM 11 8 11 8 Pressure Bar PSI 8 115 8 115 Tank Size L 50 100 RPM 2850 2850 Dimensions mm LxWxH 740 x 380 x 740 115 x 400 x 740 Weight Kg 40 52...

Page 16: ...ling centre 11 4 Certain products contain batteries which should not be disposed of in your domestic waste 11 5 You MUST recycle batteries in accordance with your local authority or recycling centre 1...

Page 17: ...t Category Electric Air Compressor Product Name Model HY3050V HY30100V Type Serial No Electric Air Compressor Net Installed Power HY3050V 2 2kW HY30100V 2 2kW The technical document is kept by Roland...

Page 18: ...ou make a warranty claim Full warranty terms and conditions can be found on the HYUNDAI POWER PRODUCTS website www hyundaipowerproducts co uk 15 0 Our manuals are constantly being reviewed and updated...

Page 19: ...19...

Page 20: ...mbroke Dock UNITED KINGDOM SA72 4RW T 44 0 1646 687 880 F 44 0 1646 686 198 E info hyundaipowerproducts co uk www hyundaipowerproducts co uk Imported Distributed by GENPOWER LTD for The United Kingdom...

Reviews: