Summary of Contents for HG2201-A

Page 1: ...1 ...

Page 2: ...ystem 2 Ground System 3 AC Applications 4 AC Operation 5 DC Operation 6 High Altitude Operation 5 PRE OPERATION CHECK 1 Engine Oil 2 Fuel Recommendation 6 STARTING STOPPING THE ENGINE 7 MAINTENANCE 1 Maintenance Schedule 2 Tool Kit 3 Engine Oil Change 4 Air Cleaner Service 5 Fuel Sediment Cup Cleaning 6 Spark Plug Service 8 TRANS PORTING i STORAGE 9 TROUBLESHOOTING 10 WIRING DIAGRAM 11 SPECIFICATI...

Page 3: ...t there is at least 1 5 metres between the generator and the walls of the building or other equipment Do not place flammable liquids or gases near the generator Do not run the generator in an enclosed or badly ventilated space The exhaust gas from the motor contains carbon monoxide which is toxic and may lead to a loss of consciousness or death Run the generator in respect of the power indicated i...

Page 4: ...ds to be replaced with another cut out the latter must correspond to the technical specifications of the generator Due to important mechanical constraints it is necessary to use a flexible sheathed cable with a strong rubber protective layer conforming to IEC 245 4 or a similar cable If using an electrical extension cable the total length of the extension must not exceed 60m when the section of th...

Page 5: ...h another generator If using electrical extensions make sure that they are sufficiently thick to transport the current and that they are used correctly The generating set shall not be connected to other power sources such as the power company supply mains The connection of a generator used for auxiliary power to the electrical installation of a building must be performed by a qualified electrician...

Page 6: ...l to avoid possible injury or even death or damage to the equipment To reduce the risk of personal injury and property damage the user must read and understand this manual before using this product It is forbidden to run the generator in an enclosed room because exhaust emissions can lead humans or animals to coma to death This symbol indicates the surface is very hot and not touching Keep away fr...

Page 7: ...7 ...

Page 8: ...8 2 COMPONENT IDENTIFICATION ...

Page 9: ... Starter Without Electric Starter Return the key to the ON position once the engine has started Do not use the starter for more than 5 seconds at a time If the engine fails to start release the switch and wait 10 seconds before operating the starter again 2 Recoil Starter To start the engine pull the starter grip lightly until resistance is felt then pull briskly NOTICE Do not allow the starter to...

Page 10: ...losed by operating the choke lever or choke rod manually Move the lever or the rod to the CLOSE position to enrich the mixture 5 Circuit Breaker The circuit breaker will automatically switch OFF if there is a short circuit or a significant overload of the generator at the receptacle If the circuit breaker is switched OFF automatically check that the appliance is working properly and does not excee...

Page 11: ...d the engine will not start If this occurs first check engine oil 4 GENERATOR USE 1 Connections to a Building s Electrical System Connections for standby power to a building s electrical system must be made by a qualified electrician The connection must isolate the generator power from utility power and must comply with all applicable laws and electrical codes WARNING Improper connections to a bui...

Page 12: ...lations which must be observed 3 AC Applications Before connecting an appliance or power cord to the generator Make sure that it is in good working order Faulty appliances or power cords can create a potential for electrical shock If an appliance begins to operate abnormally becomes sluggish or stops suddenly turn it off immediately Disconnect the appliance and determine whether the problem is the...

Page 13: ...tive terminal and black to identify the negative terminal The battery must be connected to the generator DC terminals with the proper polarity battery positive to generator red terminal and battery negative to the generator black terminal With DC Circuit Protector With DC Fuse DC Circuit Protector or DC Fuse The DC circuit protector or DC Fuse automatically shuts off the DC battery charging circui...

Page 14: ...ring problem will trip the DC circuit protector PUSH button extends out If this happens wait a few minutes before pushing in the circuit protector to resume operation If the circuit protector continues to go OFF discontinue charging and see your authorized generator dealer Disconnecting the battery cables 1 Stop the engine 2 Disconnect the negative battery cable from the generator negative termina...

Page 15: ...an air fuel mixture will reduce performance and may over heat and seriously damage the engine 5 PRE OPERATION CHECK 1 Engine oil NOTICE Engine oil is a major factor affecting engine performance and service life Non detergent and 2 stroke engine oils will damage the engine and are not recommended Check the oil level BEFORE EACH USE with the generator on a level surface with the engine stopped Use 4...

Page 16: ...he engine stopped Do not smoke or allow flames or sparks in the area where the engine is refueled or where gasoline is stored Do not overfill the fuel tank there should be no fuel in the filler neck After refueling make sure the tank cap is closed properly and securely Be careful not to spill fuel when refueling Spilled fuel or fuel vapor may ignite If any fuel is spilled make sure the area is dry...

Page 17: ...lp meet clean air standards If you use an oxygenated fuel be sure its pump octane rating is 86 or higher Ethanol ethyl or grain alcohol Gasoline containing more than 10 ethanol by volume may cause starting or performance problems Gasoline containing ethanol may be marketed under the name Gasohol Methanol methyl or wood alcohol Gasoline containing methanol must contain cosolvents and corrosion inhi...

Page 18: ...not allow the starter grip to snap back against the engine Return it gently to prevent damage to the starter or housing With electric starter Optional kit Turn the engine switch to the START position and hold it there for 5 seconds or until the engine starts NOTICE Operating the starter motor for more than 5 seconds can damage the motor If the engine fails to start release the switch and wait 10 s...

Page 19: ...tervals shown in the Maintenance schedule below 1 MAINTENANCE SCHEDULE REGULAR SERVICE PERIOD Performed at every indicated month or operating hour interval whichever comes first Each use First month or 20 Hrs 3 Every 3 months or 50 Hrs 3 Every 6 months or 100 Hrs 3 Every year or 300 Hrs 3 ITEM Engine oil Check level o Change o o Air cleaner Check o Clean o 1 Sediment Cup Clean o Spark plug Check C...

Page 20: ...dusty conditions consult your servicing dealer for recommendations applicable to your individual needs and use 2 Tool kit The tools supplied with the generator will help you to perform the owner maintenance procedures listed on the following page Always keep this tool kit with the generator NOTE Diagrams may vary according to the types 3 Engine oil change Drain the oil while the engine is warm to ...

Page 21: ...uretor malfunction service the air cleaner regularly Service more frequently when operating the generator in extremely dusty areas WARNING Using gasoline or flammable solvent to clean the filter element can cause a fire or explosion Use only soapy water or nonflammable solvent NOTICE Never run the generator without the air cleaner Rapid engine wear will result 1 Unsnap the air cleaner cover clips ...

Page 22: ...mmable or high flash point solvent 3 Reinstall o nng and sediment cup 4 Turn the fuel valve ON and check for leaks 6 Spark Plug Service Recommended spark plugs F5T or F6TC or F7TJC or other equivalents To ensure proper engine operation the spark plug must be properly gapped and free of deposits If the engine has been running the muffler will be very hot Be careful not to touch the muffler 1 Remove...

Page 23: ...k plug in by hand to prevent cross threading 7 After the spark plug is seated tighten with a spark plug wrench to compress the washer If installing a new spark plug tighten I 2 turn after the spark plug seats to compress the washer If reinstalling a used spark plug tighten I 8 1 4 turn after the spark plug seats to compress the washer NOTICE The spark plug must be securely tightened An improperly ...

Page 24: ...E TO PREVENT HARD STARTING Less than 1 month No preparation required 1 to 2 months Fill with fresh gasoline and add gasoline conditioner 2 months to 1 year Fill with fresh gasoline and add gasoline conditioner Drain the carburetor float bowl Drain the fuel sediment cup 1 year or more Fill with fresh gasoline and add gasoline conditioner Drain the carburetor float bowl Drain the fuel sediment cup R...

Page 25: ...al revolutions to distribute the oil then reinstall the spark plug 4 Slowly pull the starter grip until resistance is felt At this point the piston is coming up on its compression stroke and both the intake and exhaust valves are closed Storing the engine in this position will help to protect it from internal corrosion Align the notch on the starter pulley with the hole at the top of recoil starte...

Page 26: ...ark plug spilled fuel may ignite To check 1 Remove the spark plug cap and clean any dirt from around the spark plug 2 Remove the spark plug and install the spark plug in the plug cap 3 Set the plug side electrode on the cylinder head 4 Crank the engine sparks should jump across the gap YES YES Is the fuel reaching the carburetor Clean the fuel sediment cup If the engine still does not start take t...

Page 27: ...C circuit breaker ON Check the electrical appliance or equipment for any defects YES NO Take the generator to an authorized generator dealer NO DEFECTS Replace the electrical appliance or equipment Take the electrical appliance or equipment to an electrical shop for repair DEFECTS ...

Page 28: ...28 ...

Page 29: ...29 ...

Page 30: ...ube Oil capacity L 0 6L Noise level Measured at 4 m from machine in normal operation 94dB A Noise level Measured at 7 m from machine in normal operation 65dB A Guarantee sound power level 95dB A Generator SET Generator set AC out put Voltage 230V AC Frequency 50Hz AC rated output power PRP 2 kW AC max output power 2 2 kW S2 5min Power factor 1 0 Rated output 8 7A Performance class G1 Quality class...

Page 31: ...ctive 2011 65 EU Noise directive 2000 14 CE Annex VI 2005 88 EC Also complies with European standards with national standards and the following technical provisions EN 12601 2010 EN 55012 2007 A1 2009 EN 61000 6 1 2007 Notified body of noise certificate Société Nationale de Certification et d Homologation NB 0499 11 route de Luxembourg L 5230 Sandweiler E mail info snch lu Home page www snch lu Té...

Page 32: ...32 ...