background image

Safety 

Precautions

 

 

 

 

 

    cylinders. (No more than 80 % volume liquid charge).     i)  Do not exceed the maximum working 

    pressure of thecylinder, even temporarily.     j)  When the cylinders have been filled correctly and the 

    process completed, make sure that the cylinders and the equipment are removed from site promptly 

    and all isolation valves on the equipment are closed off.     k) Recovered refrigerant shall not be charged 

    into another refrigeration  system unless it has been cleaned and checked.

15.Labelling

    Equipment shall be labelled stating that it has been de-commissioned and emptied of refrigerant. The 

    label shall be dated and signed. Ensure that there are labels on the equipment stating the equipment 

    contains flammable refrigerant.

16.Recovery

    When removing refrigerant from a system, either for servicing or decommissioning, it is recommended 

    good practice that all refrigerants are removed safely. When transferring refrigerant into cylinders, 

    ensure that only appropriate refrigerant recovery cylinders are employed. Ensure that the correct 

    number of cylinders for holding the total system charge is available. All cylinders to be used are 

    designated for the recovered refrigerant and labelled for that refrigerant (i.e. special cylinders for the 

    recovery of refrigerant). Cylinders shall be complete with pressure relief valve and associated shut-off 

    valves in good working order. Empty recovery cylinders are evacuated and, if possible, cooled before 

    recovery occurs. The recovery equipment shall be in good working order with a set of instructions 

    concerning the equipment that is at hand and shall be suitable for the recovery of flammable refrigerants. 

    In addition, a set of calibrated weighing scales shall be available and in good working order. Hoses shall 

    be complete with leak-free disconnect couplings and in good condition. Before using the recovery 

    machine, check that it is in satisfactory working order, has been properly maintained and that any 

    associated electrical components are sealed to prevent ignition in the event of a refrigerant release. 

    Consult manufacturer if in doubt. The recovered refrigerant shall be returned to the refrigerant supplier 

    in the correct recovery cylinder, and the relevant Waste Transfer Note arranged. Do not mix refrigerants 

    in recovery units and especially not in cylinders. If compressors or compressor oils are to be removed, 

    ensure that they have been evacuated to an acceptable level to make certain that flammable refrigerant 

    does not remain within the lubricant. The evacuation process shall be carried out prior to returning the 

    compressor to the suppliers. Only electric heating to the compressor body shall be employed to 

    accelerate this process. When oil is drained from a system, it shall be carried out safely. 

Before carrying out this procedure, it is essential that the technician is completely familiar with the 

equipment and all its detail. It is recommended good practice that all refrigerants are recovered safely. 

Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is 

required prior to re-use of reclaimed refrigerant. It is essential that electrical power is available before 

the task is commenced. 

14.Decommissioning

a) Become familiar with the equipment and its operation.    b) Isolate system electrically.    c) Before 

attempting the procedure ensure that: Mechanical handling equipment is available, if required, for 

handling refrigerant cylinders;All personal protective equipment is available and being used correctly; 

The recovery process is supervised at all times by a competent person; Recovery equipment and 

cylinders conform to the appropriate standards.    d) Pump down refrigerant system, if possible.    e) If a 

vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of  the

system.     f) Make sure that cylinder is situated on the scales before recovery takes place.    g) Start the 

recovery machine and operate in accordance with manufacturer's instructions.    h) Do not overfill 

 

Page 9 

Summary of Contents for HDR 20 WIVA

Page 1: ...UPUTSTVA ZA KORI TENJE USER MANUAL HDR 20 WIVA...

Page 2: ...nje posude za vodu 17 i enje re etke i ku i ta 17 Briga i odr avanje Uklanjanje prikupljene vode 16 Druge zna ajke 14 Zna ajke upravlja ke plo e 11 Upute za uporabu Kada koristiti ure aj 11 Pozicionir...

Page 3: ...je voda mo e prskati na ure aj Ne koristite jedinicu u malim prostorima Ne vadite posudu za vodu tijekom rada Ne pijte i ne upotrebljavajte vodu koja se ispu ta iz jedinice razrje iva a itd Nemojte ko...

Page 4: ...jetilnim ili mentalnim sposobnostima ili nedostatkom iskustva i znanja osim ako im osoba Ovaj ure aj nije namijenjen za upotrebu osobama uklju uju i djecu sa smanjenim fizi kim igrati s ure ajem Djeca...

Page 5: ...ima Nije primjenjivo na jedinice koje koriste rashladno sredstvo Dru tvena napomena informacije Kada se koristi ovaj odvla iva zraka u europskim zemljama moraju se slijediti sljede e Ure aj prodajte o...

Page 6: ...du s proizvo a evim uputama Ako je za radove odr avanja i je poznat u industriji akreditiranog tijela kojom dokazuje kompetenciju u sigurnom radu s rashladnim sredstvima na temelju postupka koji Svatk...

Page 7: ...ni da nema opasnosti od zapaljivosti ili rizika od paljenja Moraju biti istaknuti znakovi Zabranjeno pu enje mo e ispustiti u okolni prostor Prije po etka rada potrebno je izvidjeti podru je oko oprem...

Page 8: ...na krug ne smije priklju iti nikakva elektri na Popravak i odr avanje elektri nih komponenata uklju uje po etne sigurnosne provjere i postupke pregleda 9 Provjere elektri nih ure aja 7 Popravci zape a...

Page 9: ...tavkom punjenja sve dok se ne postigne sigurnom Ovaj e se postupak mo da trebati ponoviti nekoliko puta Za ovaj se zadatak ne smiju koristiti komprimirani Rashladno sredstvo mora se pohraniti u isprav...

Page 10: ...acivanja rashladnog sredstva u boce osigurajte da se koriste samo Kada uklanjate rashladno sredstvo iz sustava bilo radi servisiranja ili prestanka rada preporu uje se dobra praksa da se 16 Oporaba sr...

Page 11: ...crijevo izlaz za prednji dio stra nji dio prednji dio stra nji dio stra nji dio zraka re etka za izlaz re etke zra ni filtar iza dovod zraka re etka za crijevo izlaz za odvodno prozor za razinu vode...

Page 12: ...potrijebite jedinicu za spre avanje o te enja vlagom sprije ili o te enje vlagom Odvla iva zraka koristite u podrumu kako biste kako bi bio naju inkovitiji Odvla iva zraka mora raditi u zatvorenom pro...

Page 13: ...ventilatora Spremnik pun vode Timer uklju en Timer isklju en Re im odvla ivanja Kontinuirano odvla ivanje Na ina rada su ilice Pametno odvla ivanje Zatim pritisnite tipku za upravljanje eljenim postav...

Page 14: ...o i iva zraka ili Funkcije protiv Napomena Turbo gumb onemogu en je u na inu rada i automatskog zaustavljanja zajedno s tipkama i Pritisnite za pokretanje zna ajke automatskog pokretanja Timer gumb u...

Page 15: ...vanje polo aju kada se spremnik izvadi ili ne zamijeni u odgovaraju em Svijetli kada je spremnik za vodu spreman za pra njenje ili Svijetlo punog spremnika Druge zna ajke radi 15 minuta pod velikom br...

Page 16: ...anje jedinice u bilo koje su enja nakon najvi e 10 sati rada brzini Za neke modele jedinica e napustiti na in rada u na inu rada su enja Brzina ventilatora je fiksna pri velikoj Ure aj mo e izvr iti m...

Page 17: ...aju e odvodno crijevo i odvedite ga na odvodnog priklju ka Pri vrstite presijecite poklopac sa stra njeg Uklonite gumeni ep ili gumeni ep Uklonite odvodno crijevo Pri vrstite crijevo na izlaz za jedin...

Page 18: ...ja Dijelom napunite i enje filtera zraka NAPOMENA NEMOJTE ISPIRATI NITI STAVLJATI FILTER U AUTOMATSKU PERILICU POSU A potrebno Filter zraka iza prednje re etke treba provjeriti i o istiti najmanje sva...

Page 19: ...e posuda puna Provjerite kutiju ku nog osigura a prekida a Provjerite je li utika odvla iva a gurnut u potpunosti u uti nicu U prostoriji se nalazi kerozinski grija ili ne to to dovodi do isparavanja...

Page 20: ...rite zadnju ina icu proizvo a u Bilo kakve nadopune priru nika bit e u itane na servisnoj promjenama bez prethodne najave Za detalje obratite se distributeru ili U svrhu pobolj anja proizvoda dizajn i...

Page 21: ...USER MANUAL HDR 20 WIVA...

Page 22: ...cautions 02 When using the unit 11 Positioning the unit 11 Design Notice 10 Identification of parts 10 Removing the collected water 16 Other features 14 Control Panel Features 11 When not using the un...

Page 23: ...t Do not use the machine near flammable gas or combustibles such as gasoline benzene thinner etc Do not drink or use the water drained from the unit Do not take the water bucket out during operation D...

Page 24: ...amaged contact a technician or customer service for assistance In a thunderstorm the power must be cut o to avoid damage to the machine due to lightning Do not run cord under carpeting Do not cover co...

Page 25: ...h waste separately for special treatment is necessary It is prohibited to dispose of this appliance in domestic household waste For disposal there are several possibilities When using this dehumidifie...

Page 26: ...turer Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants The appliance s...

Page 27: ...terial 4 Checking for presence of refrigerant The area shall be checked with an appropriate refrigerant detector prior to and during work to ensure the technician is aware of potentially flammable atm...

Page 28: ...s shall be disconnected from the equipment being worked upon prior to any removal of sealed covers etc If it is absolutely necessary to have an electrical supply to equipment during servicing then a p...

Page 29: ...the pipe work are to take place Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available 10 Detection of flammable refrigerants The following...

Page 30: ...has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release Consult manufacturer if in doubt The recovered refrigera...

Page 31: ...tice Preparation rear front rear front rear front control panel control panel shoes dryer cover shoes dryer pipe drain hose outlet drain hose outlet drain hose outlet power cord buckle power cord buck...

Page 32: ...to help prevent moisture damage The dehumidifier must be operated in an enclosed area to be most effective Close all doors windows and other outside openings to the room A dehumidifier operating in a...

Page 33: ...ress pad to operate the desired settings For panel H Indicator Function Indicator Function Timer ON light Timer OFF light Bucket full light Air purifier light Low fan speed light Med fan speed light D...

Page 34: ...ol to Normal Note The turbo button is disabled in Dryer mode the Self clean Air purifier or Anti mould functions Pressing the turbo button for more than 3 seconds enables the Self clean function and t...

Page 35: ...ensor error Unplug the unit and plug it back in If error repeats call for service ES Temperature sensor error Unplug the unit and plug it back in If error repeats call for service P2 Bucket is full or...

Page 36: ...on will also be cancelled There are two ways to remove collected water 1 Use the bucket When the unit is off if the bucket is full the unit will beep 8 times on some models and the Full Water indicato...

Page 37: ...the drain hose Select the desired humidity setting and fan speed on the unit for continuous draining to start 2 Continuous draining Note When the continuous drain feature is not being used remove the...

Page 38: ...ated for the dehumidifier to operate The air filter behind the front grille should be checked and cleaned at least every two weeks or more often if necessary NOTE DO NOT RINSE OR PUT THE FILTER IN AN...

Page 39: ...as it should be The floor surface is not level Hose to connector or hose connection may be loose Intend to use the bucket to collect water but the back drain plug is removed This is normal The dehumid...

Page 40: ...s are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details Any updates to the manual will be uploaded to the service website please...

Page 41: ......

Reviews: