4
Electric air conditioner (split system)
EN
3. SPECIFICATIONS
Tab.1
Indoor unit
Outdoor unit
Units
H-ARI20-07H/I
H-ARI20-07H/O
H-ARI20-09H/I
H-ARI20-09H/O
Capacity (cooling)
BTU (W)
7506 (2200)
9192 (2694)
Capacity (heating)
BTU (W)
7848 (2300)
9523 (2791)
Rated power consumption (cooling/
heating)
W/W
664/620
814/773
Power source
V/Hz
220-240~/50
220-240~/50
Amperage (cooling/heating)
А/А
2.97/2.77
3.58/3.25
Air consumption (indoor unit/outdoor
unit)
m³/h/
m³/h
420/1400
460/1700
Noise level (indoor unit)
dB
33/29/27/24
33/29/27/24
Noise level (outdoor unit)
dB
48
50
Ingress Protection Rating (indoor unit/
outdoor unit)
-
IPX0/IPX4
IPX0/IPX4
Refrigerant
-
R410A
R410A
Energy efficiency (cooling/heating)
-
A/A
A/A
IEC protection class (indoor unit/outdoor
unit)
-
I/I
I/I
Refrigerant piping (Liquid side / Gas side)
inch
1/4 & 3/8
1/4 & 3/8
Max. refrigerant pipe length
m
12
12
Maximum difference in level
m
10
10
Operating temperature range (cooling)
°C
18-47
18-47
Operating temperature range (heating)
°C
-10-25
-10-25
Filling of Freon
g
520
520
Net/gross weight (indoor unit)
kg/kg
7/8.35
7.5/9
Net/gross weight (outdoor unit)
kg/kg
21.6/23.7
25/27
Net dimensions (indoor unit/outdoor
unit)
mm/mm
690×283×199 /
660×500×240
690×283×199 /
730×545×285
Packing dimensions (indoor unit/
outdoor unit)
mm/mm
740×343×264 /
780×570×345
740×343×264 /
850×370×620
Distance between brackets (outdoor unit)
mm
540
540