Maintenance & Care

Spark Plug

Clean and re-gap every 600 hours of operation, or replace as needed. After removing the spark 
plug, clean the terminals with a wire brush. Re-gap the terminals to 0.35cm.

Screw

Igniter
Wire

Gap

Burner Head

Spark Plug

Summary of Contents for HY125DKH

Page 1: ...www hyundaipowerproducts co uk 1 DIESEL KEROSENE FORCED AIR HEATER HY125DKH HY215DKH Instruction Manual WARNING Read and understand the instruction manual carefully before use ...

Page 2: ...reference and pass it on if the machine is loaned or sold to another user This manual has been produced by Hyundai Power Products and should be kept with the product Please read and understand these instructions before you use your product Failure to do this may result in personal injury or damage to the product The safety precautions and warnings are to ensure your safety and protect you from har...

Page 3: ...tion 22 Fueling The Heater 22 Ventilation 22 Starting Procedure 23 Stopping Procedure 24 Restarting Procedure 24 Maintenance Care 25 37 Checking Your Machine 25 Storage 25 Long Term Storage 26 Maintenance 27 Fuel Fuel Tank 27 Air Filter 27 Fan Blades 28 Nozzles 29 Spark Plug 30 Photocell 31 Fuel Filter 32 Pump Pressure Adjustment 33 Fuse Replacement 34 35 Troubleshooting 36 Technical Data 37 39 Sp...

Page 4: ...ts and other people not using the unit away from the work area Be alert and shut off the unit if anyone enters work area Keep children under the watchful care of a responsible adult Stay alert watch what you are doing and use common sense when operating the machine Never operate the machine when unwell or tired or if you have taken alcohol medicine drugs or any substances which may slow your refle...

Page 5: ...leaks Keep the machine in safe working condition Do not use the machine if the switch does not turn off the machine when running Any machine that can t be controlled with the switch is dangerous and must be replaced Regularly check to see that keys and adjusting wrenches are removed from the machine area before starting it A wrench or a key that is left attached to a rotating part of the machine m...

Page 6: ...square foot 2800sq cm opening of outside air for every 29kW hr or heater rating Minimum clearance from combustibles Top 125cm Side 125cm Front 125cm During Use Walk never run with the machine Be very careful when pulling the machine toward you You must look behind you to make sure there are no obstacles before and during operations in reverse gear if applicable Do not allow the machine to pull you...

Page 7: ...in front or at rear of heater NEVER move or handle heater while still hot NEVER transport heater with fuel in its tank If equipped with a thermostat the heater may start at any time ALWAYS locate heater on a stable and level surface ALWAYS keep children and animals away from the heater Bulk fuel storage should be a minimum of 762cm from heaters torches portable generators or other sources of ignit...

Page 8: ...ical appliances upon owners Power cables and plugs should always be regularly inspected for safety If in doubt about electrical safety you must consult a qualified electrician WARNING Risk of electric shock Use only the electrical power voltage and frequency specified on the model plate of the heater Use only a local correct plug grounded outlet and extension cord ALWAYS install the heater so that...

Page 9: ...g else To avoid carbon monoxide poisoning DO NOT use Petrol Diesel powered equipment inside any of the following Home garage tent camper van mobile home caravan or boat DO NOT use in an enclosed area or moving vehicle This is not exhaustive and if you are in any doubt contact your dealer If you think you have or someone around you has been affected by carbon monoxide poisoning Get them fresh air i...

Page 10: ...el in the correct and clearly marked container ALWAYS wear correct suitable and fit for purpose Personal Protective Equipment PPE suggested items are but not limited to safety gloves and overalls To avoid sparking or arcing keep grounded conductive objects such as tools away from exposed live electrical parts and connections These events could ignite fumes or vapors Do not operate the machine with...

Page 11: ...p the engine and allow it to cool before filling the fuel tank Never remove the cap of the fuel tank or add fuel while the engine is running or when the engine is hot Loosen the fuel tank cap slowly to relieve any pressure in the tank ALWAYS keep the handles dry clean and free of oil and fuel After fueling ensure to tighten the cap securely Never use the lock function when filling with fuel Fuelin...

Page 12: ... dilute sulphuric acid Nickel cadmium potassium hydroxide alkali electrolyte Use fresh running water to wash off excess electrolyte continue this until medical assistance arrives Make sure that you do not wash the electrolyte to another part of your body or face If electrolyte comes in to contact with Eyes the electrolyte needs to be immediately washed away with large amounts of water Make sure th...

Page 13: ...chines will cause the user to feel the effects of from vibrations These vibrations can lead to white finger Raynaud s phenomenon or carpal tunnel syndrome This condition reduces the ability of the hand to feel and regulate temperature causing numbness and heat sensations and may cause nerve damage and circulatory tissue death Not all factors that lead to white finger disease are known but cold wea...

Page 14: ...tions and instructions provided with this heater can result in death serious bodily injury property loss or damage from the hazards of fire soot production explosion burns asphyxiation or carbon monoxide poisoning Only persons who can read and understand these instructions should use or service this heater Not for use in home or recreational vehicles This is a Diesel 1 K Kerosene directed fire for...

Page 15: ...NG MUST BE WORN Do not wear loose clothing gloves scarfs neckties or jewellery rings wrist watches which can be caught in moving parts HEAD PROTECTION MUST BE WORN Wear a safety helmet with a safety visor FACE SHIELD MUST BE WORN Wear a face shield to protect your face RESPIRATOR MUST BE WORN Wear a respirator Appropriate Personal Protective Equipment PPE MUST be worn at all times when operating o...

Page 16: ... harmful to children Keep out of reach of children Carefully remove the product from the packaging and examine it for any sign of damage caused during shipping Lay the contents out and check them If any part is damaged or missing you must not use the machine Contact HYUNDAI Power Products immediately You must keep the packaging material in case the machine needs to be returned or repaired Ensure t...

Page 17: ...ntents Wheels Frame Component Hardware Wheel Caps Washers Cotter Pins Axle Rear Handle Wheel Support Frame A B C D E F G User Manual 2 x Wheels 2 x Wheel Caps Frame Component Hardware 6 Screws 6 Nuts 2 x Washers 2 x Cotter Pins Axle Wheel Support Frame Rear Handle H I B C D E F G H I ...

Page 18: ...www hyundaipowerproducts co uk 18 www hyundaipowerproducts co uk 18 Features HY125DKH HY215DKH Features I B H J K L M N O P Q R S T ...

Page 19: ...rproducts co uk 19 Features HY125DKH HY215DKH Features Wheel Wheel Support Frame Rear Handle Upper Shell Lamp Digital Temperature Display Fan Guard Lower Shell Power Reset Switch Fuel Tank Thermostat Knob Fuel Cap Fuel Gauge B H I J K L M N O P Q R S ...

Page 20: ...liers to secure 4 Place heater on the assembled frame making sure that the air inlet end is by the wheels and the mounting holes on the tank flange of the heater align with holes in frame 5 Take the rear handle and align the mounting holes with the corresponding holes in the tank flange wheel frame slide a screw through the holes and loosely attach a nut Repeat for the other 2 holes then fully tig...

Page 21: ...OT use any fuel that is not approved above NOTE Diesel 1 K kerosene should only be stored in a blue container that is clearly marked Diesel 1 K kerosene Never store diesel 1 K kerosene in a red container Red is associated with gasoline NEVER store diesel 1 K kerosene in the living space Diesel 1 K kerosene should be stored in a well ventilated area outside the living area NEVER use fuel such as ga...

Page 22: ... System Protection The heater s electrical system is protected by a circuit breaker that protects the system components from damage If the heater fails check the fuse first and replace if necessary Flame Sensor The heater uses a photocell to see the flame in the combustion chamber Should the flame extinguish the sensor will stop electrical current and the heater will shut off It is always a good i...

Page 23: ...ing The setting range is from 40 F to 110 F Push the power switch to the room temperature display will light and the heater will start NOTE The room temperature display will indicate the following When room temperature is less than 0 F display will show LO If the heater does not fire the thermostat maybe set too low Turn the control knob to a higher setting until heater fires if the heater still d...

Page 24: ...pping Procedure Simply turn the power switch to OFF position and unplug the power cord Restarting Procedure 1 Wait 10 seconds after shutting off the heater 2 Turn the power switch to ON position 3 Be sure to follow all starting procedure precautions ...

Page 25: ...ingers between moving parts and fixed parts of the machine When checking your machine we recommend you Check for worn or damaged parts Make sure all nuts screws and bolts are tight Make sure all warning stickers are in place and not damaged Storage Store in a cool dry well ventilated place away from sources of ignition and varying changes in temperature Store on a flat and level surface DO NOT sta...

Page 26: ...ve seal head from drain hole tank 3 Using a small amount of diesel 1 K kerosene rinse and swirl the diesel 1 K kerosene inside of the fuel tank empty the tank fully 4 To replace push the drain head fully into the drain hole and secure by pushing the seal cap fully into the head hole IMPORTANT Never store leftover Diesel 1 K kerosene over the summer Using old fuel can damage your heater Fuel Tank D...

Page 27: ...while hot Fuel Fuel Tank Flush every 200 hours of operation or as needed Do not use water to flush the tank use fresh diesel 1 K kerosene only Air Filter The air filter should be replaces or washed with soap and water and dried thoroughly every 500 hours of operation or less depending on conditions The output and lint filter should be replaces every 500 hours of operation or less depending on cond...

Page 28: ...eaned at least once per heating season depending on condition Remove all accumulated dust and dirt with a damp cloth taking care not to bend any of the fan blades be sure fan blades are dry before re starting the heater For fan removal see below Set Screw Motor Shaft Fan Blade Flush ...

Page 29: ...y be necessary to soak nozzle in clean diesel 1 K kerosene to help loosen any particles NOTE Use of diesel 1 K kerosene may require an additional maintenance Using this heater without proper maintenance or with contaminated or old fuel may lead to improper combustion and possible soot production BE SURE FUEL USED IS APPROVED Burner Head Burner Head Screw Spark Plug Ignitor Wire Fuel Line Hose Air ...

Page 30: ...intenance Care Spark Plug Clean and re gap every 600 hours of operation or replace as needed After removing the spark plug clean the terminals with a wire brush Re gap the terminals to 0 35cm Screw Igniter Wire Gap Burner Head Spark Plug ...

Page 31: ...once per heating season or more depending on condition Use a cotton swab dipped in water or alcohol to clean the lens of the photocell Note the proper photocell position as noted in the diagrams Photocell Photocell Lens Photocell Wire Circuit Board HY70DKH Only Installing Photocell 1 Incorrect 2 Correct ...

Page 32: ...n diesel 1 K kerosene Contaminated fuel could make this necessary immediately NOTE To remove the fuel filter please draw out the rubber plug directly Use of diesel may require additional maintenance Improper maintenance can lead to poor combustion and soot production Power Switch Power Switch Wire Side Cover Fuel Line Screw Fuel Filter Circuit Board Photocell Wire ...

Page 33: ...ncrease Counter clockwise to decrease Use flat blade screw driver to turn valve Correct pump pressure as follows Model Pump Pressure Kpa Psi HY125DKH 38 0 5 5 HY215DKH 52 0 7 5 For best measurement of pressure test with full tank of fuel Optimum pressure occurs when the nose cone is cherry red and there are no extending flames from the heater Adjusting Screw ...

Page 34: ... into a power source turn the machine switch to off position turn the socket switch off then remove from socket 2 With a 7mm Spanner OR Phillips Screwdriver remove the 4 bolts in each corner of the control panel as shown 3 With the bolts removed gently pull the control panel away from the unit body exposing the control board Rest the control panel on the unit frame allowing it to hang may cause da...

Page 35: ...e damage to the fuse and or the holder Repeat the instructions from Step 1 Remove Control Panel in reverse to retrun the unit to a useable state 4 To test if the replacement has been successful plug the machine into a power source Put the power source and unit switches to the On position The Room Temperature display should illuminate If you have followed these steps and the temperature display doe...

Page 36: ... nozzle 6 Rinse out fuel tank with clean fresh diesel 7 Inspect all electrical connection see wiring diagrams 8 Re attach igniter wire to spark plug 9 Replace igniter Fan does not operate when heater is plugged in and power switch is in the ON position The lamp is flickering or on and LED display shows E1 or E2 1 flash or 2 flashes 1 Thermostat is set too low 2 Broken electrical connection between...

Page 37: ...gram LED LAMP LED DISPLAY THERMOSTAT TEMP CONTROL J3 CDS J5 J2 FUSE 5A 250VAC TEM AC 220 240V 50HZ LIMIT CONTROL POWER SWITCH WHITE BLACK GREEN BLACK BLUE BLUE BLUE BLACK BLACK BLUE RED GREEN RED IGNITOR PUMP MOTOR J1 GYB CAPACITOR MOTOR1 MOTOR2 DJ N AC N DJ L ...

Page 38: ...n L Hr 3 6 5 8 Fuel Tank Capacity L 38 50 Fuel Diesel or Kerosene Diesel or Kerosene Max Outlet Air Temperature 404 C 516 C Pump Pressure Kpa 38 52 Power Supply V Hz A 230 50 5 230 50 5 Phase Single Single Net Weight kg 22 1 23 5 Product Dimensions Model HY125DKH HY215DKH Length 105cm 120cm Width 54 2cm 60cm Height 62cm 62cm ...

Page 39: ... 125 EC Energy Related Products ERP 2014 30 EU Electromagnetic Compatibility Directive 2011 65 EU RoHS 2 0 Directive EN 13842 2004 Oil fired forced convection air heaters Stationary and transportable for space heating Statement of Declaration We the importer and authorised representative of the product described confirm conformity within the provisions of applicable regulations and directives list...

Page 40: ...atible with the environment We are a Member of the VALPAK National Compliance Scheme and our registration number is RM08660 For further information about disposal please contact your Local Authority You can also get more advice and guidance about recycling at the following website http www recycle more co uk Should you pass this product on to another user either sold or loaned you MUST pass on thi...

Page 41: ...tance We reserve the right to make any modifications without prior notice whenever necessary Our latest manuals are also placed online All our manuals can be downloaded at www hyundaipowerproducts co uk If you are returning your product please contact the dealer for their returns policy We work very hard to give all of our customers the best possible service If you have any problems before leaving...

Page 42: ... the machine we recommend that you fill out the following If you need to contact an authorised dealer or customer service for information on servicing you may need to provide the following information The model number and serial number can be found on the grey specification sticker on your machine Product Information Product Record ...

Page 43: ...ur team on 01646 687880 open Monday Friday 8 30am 5pm Email aftersales hyundaipowerproducts co uk Online Live Chat Go to www hyundaipowerproducts co uk Live chat is open Monday Friday from 8 30am 5pm Post Genpower Limited Isaac Way Pembroke Dock Pembrokeshire SA72 4RW UK Contact Us Need help Talk to our experts ...

Page 44: ...Way London Road Pembroke Dock UNITED KINGDOM SA72 4RW T 44 0 1646 687 880 F 44 0 1646 686 198 E info hyundaipowerproducts co uk www hyundaipowerproducts co uk Imported Distributed by Genpower Ltd for The United Kingdom Ireland Licensed by Hyundai Corporation Korea ...