background image

Hytronik   LED driver

25

Hytronik   LED driver   

26

Model:  HEM06-T  HEM07-T

Emergency LED Driver

Advanced Version

This emergency lighting module is designed to convert a wide range of LED types, and is an ideal choice for converting most standard LED 
luminaires and arrays containing from  4 to 22 ( HEM06-T ) or 4 to 20 ( HEM07-T ) LEDs in series.

 
This unit is designed to utilize the existing LED driver and panel layout (no need to break into the LED circuit) to be dimmed to 3W/6W in case 
of emergency.

The driver can automatically adjust the output LED current to provide the optimum match between the battery and the load, which enables 
maximum illumination whilst ensuring full battery duration. The driver is compatible with a wide range of LEDs such as Philips Fortimo DLM, SLM 
and LLM ranges, Bridgelux LS/ES/RS ranges, Citizen 4~41W ranges, GE Infusion, Xicato and many others.      

 Wiring  Diagram

Dual Wattage

Emergency Driver

3W

6W

EL -T

Self-testing

Emergency Driver

Emergency 

Carrying out routine test on emergency lighting and holding records of the test result is requred by the law. (IEC62034, BS5266, EN50172). 
Hytronik advanced LED emergency control model HEM06-T has a internal clock, programmed to interrupt the permanent mains supply at 
pre-determined intervals to perform the requested routine testing: 3min. funcitonal test every month, and 1h (3W) & 20min (6W) function test 
every 6 months, and 3h (3W) & 1h (6W) function test every 12 months.

------ Self-test starts after the luminaire are connected to mains for continued 48 hours.
------ Auto-commissioning, save manpower and maintenance.
------ Permanently monitors battery and charge condition
------ Dual failure indication: failures are clearly identified on the luminaire by red LED and buzzer.
------ MCU programmed test schedule: 
       HEM06-T: 3min @ every month;1h (3W) & 20min (6W) @ 6 months; 3h (3W) & 1h (6W)  @ 12months.
       HEM07-T: Emergency time 3h: 3min @ every month;1h (3W) @ 6 months; 3h (3W) @ 12months. (ex-work defaut value)
                      Emergency time 1h: 3min @ every month;20min (3W) @ 6 months; 1h (3W) @ 12months.
------  Automatic  delayed  test  in  case  of  power  failure  at  programed  testing  period.                          

Self-testing Feature

Highlights

• Deep discharge protection

5-Year product warranty     

Good compatibility with various brands of LED in the market     

• Constant current charger

High temperature NiMH/Nicd cells

• Automatic output current adjustment

Wide range of LEDs in series (HEM06-T: 12~70V / HEM07-T: 12~55V) 

• With both LED indication and Buzzer warning

• Built-in MCU programed self-testing, maintenance free

• Dual wattage and duration selection: 

HEM06-T: 3W @ 3 hrs; 6W @ 1h / HEM07-T: 3W @ 3hrs; 3W @ 1h 

Black

Red

Lout

Lin

N

L

LED

Buzzer

+

-

+

-

+

-

+

-

From LED driver

Output to LEDs

Battery supply

Reset

3W output
6W output

150

172.5

180

4.5

40.5

22

53.5

30.5

Mechanical Structure

Model:  HEM06-T

Model:  HEM07-T

Lin

Red

LED indication

Black

Lout

Buzzer

From driver

Output to LEDs

Battery supply

Reset
Emergency time 

selection

Sensor

Connection

On-off

Green

Red

Unswitched

LED Driver

LED

Battery

1.2V

1.2V

1.2V

1.2V

1.2V

1.2V

HEM06-T

From LED 

-

+
-
+

-

+

-

Output to LEDs

Battery supply

L

Lin

Lout

Buzzer

Red
Black

LED Indication

N

Reset

Output

3W
6W

Reviews: