Hytronik HCD038 Quick Start Manual Download Page 3

Hytronik   Microwave motion sensor   

131

Functions and Features

Tri-level Control (Corridor Function)

1

Hytronik builds this function inside the motion sensor to achieve tri-level control, for some areas which require a light change notice 
before switch-off.  The sensor offers 3 levels of light: 100%-->dimmed light (natural light is insufficient) -->off; and 2 periods of 
selectable waiting time: motion hold-time and stand-by period; Selectable daylight threshold and freedom of detection area.  

With sufficient natural light, the 
light does not switch on when 
presence is detected.

With insufficient natural light, 
the sensor switches on the light 
automatically when presence is 
detected.

After hold-time, the light dims to 
stand-by level if the surrounding 
natural light is below the 
daylight threshold.

Light switches off automatically 
after the stand-by period 
elapses. 

www.hytronik.com

Summary of Contents for HCD038

Page 1: ...0 O 150 O 0 2mW 5 8GHz 75MHz High Frequency microwave Sensor principle Operation frequency Transmission power Detection range Detection angle 868MHz FSK mode default RF frequency 30m indoor 50m outdoo...

Page 2: ...ected by the RF sensor antenna SAM8 will operate all other units programmed on the same group via RF transmission The transmission can reach 30 meters indoor and 50 meters in open areas A daylight sen...

Page 3: ...t off and 2 periods of selectable waiting time motion hold time and stand by period Selectable daylight threshold and freedom of detection area With sufficient natural light the light does not switch...

Page 4: ...ns in dimming level at night 3 21 40 The light automatically turns on at 10 when natural light is insufficient no motion 5 17 40 2 21 10 Settings on this demonstration Hold time 10min Daylight thresho...

Page 5: ...e Absence Detection 6 It is easy to forget to switch off the light in office corridor even at home And in many other cases people do not want to have a sensor to switch on the light automatically for...

Page 6: ...V Designed in the software sensor switches on off the load right at the zero cross point to ensure that the in rush current is minimised enabling the maximum lifetime of the relay 7 Wiring Diagram DAL...

Page 7: ...100 100 100 SAM8 SAM11 HC034RF slave 4 The person walks to the 3rd floor the 3rd SAM8 switches the light on 100 All slaves on the 3rd floor turn the light on and the SAM8 on the 4th floor switches on...

Page 8: ...nd Twilight functions are disabled Power output Press the buttons to adjust the light brightness during hold time Brightness Detection range valid for master only Scene program 1 key commissioning 1 P...

Page 9: ...ing level at 10 20 30 50 HF PIR HF PIR HF PIR are disabled For RF grouping via remote control please refer to steps below Short press Learn Erase button on RC to activate pairing mode and the receiver...