background image

5. Wiring Diagram

P

1-10V

L
N

+

-

+

+

-

-

L’N N L

L N

LED

Max. 800W

1-10V

LED driver

HIM11

+

+

-

-

L N

LED

1-10V

LED driver

2. Installation 

1. Technical Specifications

Product type                                  Dual sense motion sensor ( HF and PIR, Tri-level control )
Operating voltage                          120~277VAC  50/60Hz
Rated load                                    Capacitive: 400VA@120V; 800VA@220~277V
                                                    Resistive: 700W@120V; 1600W@220~277V
Power consumption                       < 1W
Detection angle                             360

o

Detection range                            10% / 50% / 75% / 100%
Hold time                                      2s / 30s / 1min / 5min / 10min / 15min / 20min / 30min
Stand-by time                               0s / 10s / 1min / 5min / 10min / 30min / 1h / +∞ 
Stand-by dimming level                 10% / 20% / 30% / 50%
Daylight threshold                          2 ~ 500Lux, Disable
Warmming up time                        30s
Operating temperature                   -20

o

C ~ +55

o

C

Sensor mode                                 PIR, HF, PIR+HF, PIR / HF 

3. Rotary Switch Settings

A rotary switch is built inside the sensor for 
scene selection / fast programming. Total 
16 channels available:

Note: settings can also be changed by remote control HRC-11. The last action controls.

Rotary switch preset (Please 
see the location in 2. Installation)

Warnings: 

1. Installation must be carried out by a
    qualified engineer in accordance with
    local regulations.
2. Disconnect supply before installing.
3. Install to a solid surface - vibrations may
    cause mis-triggering.
4. Ensure environmental conditions are
    suitable for electronic equipment

Detection 

range 

Channel

0
1
2
3
4
5
6
7
8
9
A




100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
75%
50%
100%
100%
100%

5s
1min
5min
5min
5min
5min
5min
10min
10min
10min
10min
10min
10min
30min
30min
5s

10s
5min
10min
30min
0s
+∞
+∞
10min
30min
+∞
+∞
+∞
+∞
+∞
+∞
10s

10%
10%
10%
10%
Disable
10%
30%
10%
10%
10%
30%
10%
10%
10%
30%
10%

Disable
2Lux
10Lux
30Lux
10Lux
30Lux
Disable
2Lux
10Lux
30Lux
Disable
30Lux
10Lux
50Lux
Disable
2Lux

Hold 

time

Stand-by 

time 

Stand-by 

dimming level 

Daylight 

threshold

4. Sensor Mode Selection

Sensor mode can be easily selected by choosing the correct combination of the DIP switches 
(see table below): 

HIM11-20190104-A1

HF

PIR

HF+PIR

HF/PIR

1 2

I

II

III

IV

HF+PIR: Light is on when both HF 
and PIR sensors are activated.

HF/PIR: Light is on when HF or PIR
sensors are activated. 

Installation and Instruction Manual

 

SURFACE MOUNT DUAL SENSE MOTION SENSOR HIM11

Infrared receiver

HF Sensor module

Photocell

PIR

LED indicator

Sensor mode selection

Rotary switch preset

A - Control Board

Direct junction “J” box mounting

a. Separate control board (A) from facia (B) 
    & junction box (C).
b. Make electrical connections to control board 
    (A). See detailed wiring diagram on next page.
c. Secure control board (A) to junction box (C).
d. Set-up sensor modes as per sections 3 & 4 
    of this manual.
e. Clip facial plate (B) to control board (A).

Surface mount assembly

a. Separate control board (A) from facia (B) &
    Surface box (C).
b. Securely mount surface box (C) to a flat and
    solid surface.
c. Make electrical connections to control board 
    (A). See detailed wiring diagram on next page.
d. Set-up sensor modes as per sections 3 & 4 of
    this manual.
e. Secure control board (A) to surface box (C).
f. Clip facial plate (B) to control board (A).

* Note: if neither function 5.2 nor 5.3 is desired, simply leave the “push” terminal disconnected.

Note: the blinds are optional, they may be inserted behind the lens for focussing the detection range.

29

56

50.2

55.2

109

38.6

56

A

B

C

56

A

B

C

Blind

A

B

Blind

C - Surface box

B - Facia Cover

11 43.5

64.7 69.1

Note:We recommend the mounting distance between sensor to sensor 
should be more than 2m to prevent sensors from false-triggering.

Detection area (Max.)*

Installation Height : 6m
Detection Range (Ø) :12m

Reviews: