15
mismatch and improper antenna could result in poor transmitting performance and even damage to
the transmitter. If yes, please contact your local dealer to replace the antenna or reprogram your
product.
2. Check if the connection between the transmitter and RF cable or antenna feed line is loose or
damaged. If yes, secure or replace the cable or antenna feed line.
3. If you cannot solve the problem, contact your local dealer for technical support.
When the VSWR falls within the normal range, the prompt message will disappear, and the Alarm
Indicator will go out.
Low Forward Power Alarm
When the forward power is below the preset value, the Alarm Indicator will glow red and the LCD will
display the prompt message below:
Then the repeater may continue transmission or terminate it, subject to the detection result. You need to:
1. Check if the connection between the transmitter and RF cable or antenna feed line is loose or
damaged. If yes, secure or replace the cable or antenna feed line.
2. If you cannot solve the problem, contact your local dealer for technical support.
When the forward power is recovered to its normal value, the prompt message will disappear, and the
Alarm Indicator will go out.
Over/Low Voltage Alarm
When power voltage is detected to be over or below the range (11V-15.6V) of repeater, the Alarm
Indicator will glow red and the LCD will display the prompt message below: