5000 SRM 969
Operation
INDICATOR LIGHTS AND LEDS
There are four indicator lights on left side of attach-
ment and five LEDs in operator’s cab. See Figure 5
and Figure 6. Indication is as follows:
• Left Amber Light and LED indicate attachment is
seated on left side and ready to have twist locks
activated.
• Green Light and LED indicate that both twist locks
are in locked position and ready to lift the con-
tainer.
• Red Light and LED indicate that both twist locks
are in unlocked position. It is now possible to move
the twist locks into or out of the corner pockets.
• Right Amber Light and LED indicate attachment
is seated on right side and ready to have twist locks
activated.
• Blue LED (cab only) indicates that overlowering
interrupt function or lift interrupt is activated.
1.
LEFT AMBER LED
2.
GREEN LED
3.
RED LED
4.
RIGHT AMBER LED
5.
BLUE LED
Figure 5. Indicator LEDs
LIFT INTERRUPT AND OVERRIDE
WARNING
Only use override feature for the positioning of
twist locks to enable proper locking. Do not use
override feature for general lifting and trans-
port of container.
When attachment is seated and any of the twist locks
are between unlocked and locked position, the blue
LED inside operator’s cab will illuminate and lift in-
terrupt system will not allow lifting of mast.
To override lift interrupt feature, turn override key
switch clockwise and push override button while us-
ing lift lever.
1.
LEFT AMBER
LIGHT
2.
GREEN LIGHT
3.
RED LIGHT
4.
RIGHT AMBER
LIGHT
Figure 6. Indicator Lights
OVERLOWERING INTERRUPT AND
OVERRIDE
WARNING
When lifting after using the override feature,
verify that chains, hoses, and cables are not ob-
structed in any way.
An overlowering interrupt feature is incorporated
on models 553 and 558. The overlowering interrupt
function prevents further lowering of attachment
when both end beams have been raised in relation
to outer booms. This prevents slacking of chains,
hoses, and wires over the mast. It also reduces shock
on attachment. The blue LED in operator’s cab will
illuminate when lowering interrupt is activated.
To override overlowering interrupt feature, turn
override key switch clockwise and push override
button while using lowering lever.
9
Summary of Contents for F007
Page 1: ...Hyster F007 H170HD H190HD H210HD H230HD H250HD H280HD Forklift...
Page 8: ...Operation 5000 SRM 969 Figure 1 Empty Container Attachment 2...
Page 10: ...Operation 5000 SRM 969 Figure 2 End Beam Assembly Model 553 4...
Page 13: ...5000 SRM 969 Operation Figure 4 End Beam Assembly Model 558 7...
Page 19: ...5000 SRM 969 Extension Cylinders Repair Figure 8 Extension Cylinder 13...
Page 36: ...Diagrams Schematics or Arrangements 5000 SRM 969 Figure 15 Hydraulic System Model 553 30...
Page 38: ...Diagrams Schematics or Arrangements 5000 SRM 969 Figure 17 Hydraulic System Model 558 32...
Page 43: ...5000 SRM 969 Diagrams Schematics or Arrangements Figure 21 Electric Diagram 37...
Page 45: ...5000 SRM 969 Diagrams Schematics or Arrangements Figure 22 Wiring Diagram 39...
Page 46: ...Diagrams Schematics or Arrangements 5000 SRM 969 Figure 23 Electric Schematic Diagram 40...
Page 47: ......
Page 48: ...TECHNICAL PUBLICATIONS 5000 SRM 969 9 03 8 01 Printed in U S A...