e
merGency
f
aSt
O
perate
(efO)
Setting the Emergency Fast Close
To enable the Emergency Fast Close option on a HydraSwing operator, you need to program the Smart Touch
Controller by taking the following steps:
NOTE:
When you are in programming mode the buttons on the keypad change from Open, Close, and
Stop to Previous, Next, and Select. Refer to
1. Make sure the operator is turned ON and a Run mode status (ex., GATE
OPEN) appears on the Smart Touch Controller, which indicates the
machine is operational.
2. Press the Menu button twice to access the User Menu.
3. Press and hold the Reset button and then the Open button. Hold the
buttons for two seconds and then release both buttons to access the
Installer Menu.
4. Press Next until the Emergency Close OC 0 appears on the display.
5. Press Select and OC starts blinking, which indicates the display can be
changed.
6. Press Next or Previous to change the display to OC 1.
7.
Press Select to accept the entry. (The display characters stop blinking.)
8. Press Program to exit programming mode and return to Run mode.
A Run mode gate status appears (ex., GATE OPEN).
Installing a Push-Button Device for EFC
The Emergency Fast Close is designed for a constant hold function, such as a push-button device that is held
for the duration of gate travel. To operate properly, a device must be connected between Terminal 23 on the
Smart Touch Controller and a +24VDC terminal on the Power Module.
When the connections are made, a constant hold signal transmitted
to the Smart Touch Controller causes the Emergency Fast Close
function to close the gate at a higher speed than usual, and photo
eyes, vehicle loop inputs, and other safety devices are ignored.
OC 1
EMERGENCY CLOSE
STOP BUTTON
OPEN BUTTON
CLOSE BUTTON
REMOTE OPEN AND
RADIO CONTROL
OPEN/CLOSE
1
OPEN PARTIAL
INTERLOCK OPEN
TIME CLOCK OPEN
FREE EXIT DETECTOR
DISABLE EXIT DETECTOR
DISABLE CLOSE TIMER
INSIDE OBSTRUCTION
VEHICLE DETECTOR
OUTSIDE OBSTRUCTION
VEHICLE DETECTOR
SHADOW/RESET
VEHICLE DETECTOR
EDGE SENSOR
PHOTO EYE POWER
24 VOLTS COMMON
PHOTO EYE POWER
DO NOT USE
PHOTO EYE
OPEN DIRECTION
DO NOT USE
PHOTO EYE
CLOSE DIRECTION
DO NOT USE
CHARGER
AC LOSS
LOCK INTERLOCK
EMERG CLOSE
FIRE DEPT OPEN
2
3
4
5
6
7
8
9
10
11
12
14
15
16
17
18
19
20
21
22
23
24
Smart Touch Controller
LIMIT
DUAL GATE
RADIO OPTIONS
DRIVE
POWER
RS485
MO
TOR
USER 1
USER 2
USER 3
VEHICLE DETE
CT
OR
VEHICLE DETE
CT
OR
VEHICLE DETE
CT
OR
ST
OP
/B
UZZER
FREE
EXIT
INSIDE
OB
STR
OUT
SIDE
OB
STR
SHADO
W
RE
SET
WIE
GAND
Hy
Security
COM
NO
MX000585
VERSION
S/N
RS232
DI
SPLA
Y
VEHI
CLE DETE
CT
OR
COM
COM
A
B
RPM
COM
OPEN
EDGE
+24V
+24V
STATUS
LED
24V A
C Acc
essor
y pow
er
+ 24
V D
C
Power Connector
Power Module
COM
MO
N
Emergency Fast
Close Device
(Actuator)
28
MX3636-01 Rev. D
HydraSwing Programming & Operations
© 2018
Summary of Contents for HSG80F
Page 2: ...www SecureOpeners com 800 878 7829 Sales SecureOpeners com...
Page 14: ...Page intentionally left blank xiv MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 36: ...Page intentionally left blank 22 MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 124: ...110 MX3636 01 Rev D HydraSwing Programming Operations 2018 Page intentionally left blank...
Page 136: ...122 MX3636 01 Rev D HydraSwing Programming Operations 2018...