Obligations of the Operator and Disposal

8

Obligations of the Operator and Disposal

This chapter contains the following subsections:

§

Obligations of the Operator

§

Dismantling / Disposal

8.1

Obligations of the Operator

European Union

In the Single European Market it is the responsibility of the operator to ensure that  the  following  legal  regulations  are
observed  and  complied  with:  national  implementation  of  the  framework  directive  (89/391/EEC)  and  the  associated
individual  directives,  in  particular  2009/104/EC,  on  minimum  safety  and  health  requirements  for  the  use  of  work
equipment by employees at work.

Worldwide

Regulations: If and where required, operating licences must be obtained by the operator. In addition, national or regional
environmental  protection  requirements  must  be  complied  with,  regardless  of  local  legal  provisions  regarding  the
following topics:

§

Occupational safety

§

Product disposal

Connections: Local regulations for electrical installation and connections must be observed.

8.2

Dismantling / Disposal

When disposing of the units and their accessories, the applicable local regulations regarding environment, disposal  and
occupational safety must be observed.

Before dismantling

§

Electrical Devices:

§

Switch off the units.

§

Disconnect electrical appliances from the power supply, regardless of whether the appliances are connected to the
mains or to another power source.

§

Mechanical devices: 

§

Fix all loose components. Prevent the device from moving independently or unintentionally.

§

Loosen mechanical fastenings: Please note that appliances can be heavy and that loosening the fastenings may cause
them to become mechanically unstable.

Disposal

Operators of old appliances must recycle them separately from  unsorted  municipal  waste.  This  applies  in  particular  to
electrical waste and old electronic equipment.

Electrical waste and electronic equipment must not be disposed of as household waste! 

Instead, these old appliances must be collected separately and disposed of via the local collection and return systems.

Integrated  or  provided  batteries  and  accumulators  must  be  separated  from  the  appliances  and  disposed  of  at  the
designated collection point.

23

23

Summary of Contents for TB4 2 Series

Page 1: ...TB4 Series 2 User Manual...

Page 2: ...Gauge 7 2 2 Site Selection and Setup 7 Part III Configuration 11 3 1 Calibration 11 3 2 Field Calibration Device 11 Part IV Operation 12 4 1 Test Operation 12 4 2 Electrical 12 Part V Maintenance 13 P...

Page 3: ...rmation provided in this manual was deemed accurate as of the publication date However updates to this information may have occurred This manual does not include all of the details of design productio...

Page 4: ...2022 HyQuest Solutions 4 II Scope of Delivery TB4 Series II T Rain gauge TB311 5 5 metre connecting lead 2022 HyQuest Solutions 4...

Page 5: ...d before starting to work as well as for defects found while working Do not use the HyQuest Solutions TB4_Series2 in areas where there is a danger of explosion The present user manual specifies enviro...

Page 6: ...ccuracy and robustness needed to fulfil the requirements of measurement practitioners in the field The present User Manual will help you understand install and deploy the device If however you feel th...

Page 7: ...ain gauge is now ready for installation 2 2 Site Selection and Setup Site Selection Rainfall measurements are intended to be representative of the actual rain falling on a given area Some of the more...

Page 8: ...2022 HyQuest Solutions 8 Installation Pole Mount...

Page 9: ...2022 HyQuest Solutions 9 Installation Roof Mount The Rain Gauge can also be mounted on a pitched roof with maximum angle of 15 degrees...

Page 10: ...2022 HyQuest Solutions 10 Installation...

Page 11: ...e from HyQuest Solutions Pty Ltd Field Calibration Device Model FCD for routine field check calibrations supplied with operating instruction sheet refers to FIELD CALIBRATION DEVICE Laboratory Calibra...

Page 12: ...freely Replace and secure the enclosure 4 2 Electrical Dual reed switches are provided for several reasons Two isolated switches permit the control of two separate circuits e g a local counter and a...

Page 13: ...y for cleanliness Catch filter Syphon refer diagram 5 Interior of bucket Top surface of adjusting screws Enclosure locking screws lightly lubricate after cleaning All insect screens Dismantle Details...

Page 14: ...2022 HyQuest Solutions 14 Maintenance Assembly Details a Screw cap on stem Finger tight only b Push stem into syphon body c Replace nut and tighten Do not over tighten...

Page 15: ...urn shipment 2 Please provide as much information and or clear instructions within the return paperwork This will assist our test engineers with their diagnosis 3 Please do not ship the goods prior to...

Page 16: ...0 01 Series II T Tipping Bucket Rain gauge bucket capacity 0 01inch bucket type Teflon Impregnated injection moulded non hydroscopic plastic ASA UV stabilised TB4 0 5 Series II T Tipping Bucket Rain g...

Page 17: ...ELF TAPPING SCREW 304 PAN HD PHILLIPS STAINLESS STEEL 1 9 TB307 MODEL TB3 RAIN GAUGE 24V REED SWITCH ASSEMBLY 0 5 10 SC023 09 BULL S EYE LEVEL 1 11 SC100 09 SERIAL PLATE 1 12 SC100 06 CALIBRATED LABEL...

Page 18: ...2022 HyQuest Solutions 18 Repair TB4 Series II Bucket Part List...

Page 19: ...2022 HyQuest Solutions 19 Repair Syphon Part List...

Page 20: ...2022 HyQuest Solutions 20 Repair Filter Part List Enclosure Part List...

Page 21: ...2022 HyQuest Solutions 21 Repair Part no Description Quantity TB337 01 Funnel 1 TB337 02 Enclosure 1 TB418 06 Vent 1 SC022 72 Screw 3 TB337 breakdown assembly...

Page 22: ...oated brass Synthetic ceramic coated brass Pivot Bucket Mechanism Machined robust stainless steel axle resting on corrosion free sapphire pivots Enclosure and Base Anodized powder coated aluminium Acc...

Page 23: ...ctions must be observed 8 2 Dismantling Disposal When disposing of the units and their accessories the applicable local regulations regarding environment disposal and occupational safety must be obser...

Page 24: ...re committed to supporting efforts to avoid and recycle waste Please consider Avoidance before recycling Recycling before disposal This symbol indicates that the scrapping of the unit must be carried...

Page 25: ...S Group HyQuest Solutions KISTERS LATAM HyQuest Solutions NZ Ltd HyQuest Solutions Pty Ltd HyQuest Solutions KISTERS AG 1 561 459 4876 sales hsa kisters net 57 350 575 4079 sales latam hyquestsolution...

Page 26: ...www hyquestsolutions com 2022 HyQuest Solutions 21 04 2022...

Reviews: