background image

§

Read the user manual including all operating instructions prior to installing, connecting and powering up the HyQuest
Solutions TB4_Series2. The manual provides information on how to operate the product. The manual is intended to be
used  by  qualified  personnel,  i.e.  personnel  that  have  been  adequately  trained,  are  sufficiently  familiar  with
installation, mounting, wiring, powering up and operation of the product.

§

Keep the user manual on hand for later reference!

§

If  you  encounter  problems  understanding  the  information  in  the  manual  (or  part  thereof),  please  consult  the
manufacturer or its appointed reseller for further support.

§

HyQuest  Solutions  TB4_Series2  is  intended  to  be  used  in  hydrometeorological  or  environmental  monitoring
applications. 

§

Before starting to work, you have to check the functioning and integrity of the system.

§

Check for visible defects on the TB4_Series2, this may or may  not  include  any  or  all  of  the  following  mounting
facilities,  connectors  and  connections,  mechanical  parts,  internal  or  external  communication  devices,  power
supplies or power supply lines, etc.

§

If defects are found that jeopardize the operational safety, work must be stopped. This is true for  defects  found
before starting to work as well as for defects found while working.

§

Do not use the HyQuest Solutions TB4_Series2 in areas where there is a danger of explosion.

§

The present  user  manual  specifies  environmental/climatic  operating  conditions  as  well  as  mechanical  and  electrical
conditions. Installation, wiring, powering up and operating  the  HyQuest  Solutions  TB4_Series2  must  strictly  comply
with these specifications.

§

Perform maintenance only when tools or machinery are not in operation.

§

If guards are removed to perform maintenance, replace them immediately after servicing.

§

Never  make  any  electrical  or  mechanical  diagnostics,  inspections  or  repairs  under  any  circumstances.  Return  the
sensor to the manufacturer’s named repair centre. You can find information on how to return items for repair in the
relevant section of the HyQuest Solutions web site.

§

 Disposal instructions: After taking the HyQuest Solutions TB4_Series2 out of service, it must be disposed of in

compliance  with  local  waste  and  environmental  regulations.  The  HyQuest  Solutions  TB4_Series2  is  never  to  be
disposed in household waste!

§

 Inputs and outputs of the device are protected against electric discharges  and  surges  (so-called  ESD).  Do  not

touch any part of the electronic components! If you need to touch any part, please discharge yourself, i.e. by touching
grounded metal parts.

III        Safety Instructions

© 2022 HyQuest Solutions

5

Summary of Contents for TB4 2 Series

Page 1: ...TB4 Series 2 User Manual...

Page 2: ...Gauge 7 2 2 Site Selection and Setup 7 Part III Configuration 11 3 1 Calibration 11 3 2 Field Calibration Device 11 Part IV Operation 12 4 1 Test Operation 12 4 2 Electrical 12 Part V Maintenance 13 P...

Page 3: ...rmation provided in this manual was deemed accurate as of the publication date However updates to this information may have occurred This manual does not include all of the details of design productio...

Page 4: ...2022 HyQuest Solutions 4 II Scope of Delivery TB4 Series II T Rain gauge TB311 5 5 metre connecting lead 2022 HyQuest Solutions 4...

Page 5: ...d before starting to work as well as for defects found while working Do not use the HyQuest Solutions TB4_Series2 in areas where there is a danger of explosion The present user manual specifies enviro...

Page 6: ...ccuracy and robustness needed to fulfil the requirements of measurement practitioners in the field The present User Manual will help you understand install and deploy the device If however you feel th...

Page 7: ...ain gauge is now ready for installation 2 2 Site Selection and Setup Site Selection Rainfall measurements are intended to be representative of the actual rain falling on a given area Some of the more...

Page 8: ...2022 HyQuest Solutions 8 Installation Pole Mount...

Page 9: ...2022 HyQuest Solutions 9 Installation Roof Mount The Rain Gauge can also be mounted on a pitched roof with maximum angle of 15 degrees...

Page 10: ...2022 HyQuest Solutions 10 Installation...

Page 11: ...e from HyQuest Solutions Pty Ltd Field Calibration Device Model FCD for routine field check calibrations supplied with operating instruction sheet refers to FIELD CALIBRATION DEVICE Laboratory Calibra...

Page 12: ...freely Replace and secure the enclosure 4 2 Electrical Dual reed switches are provided for several reasons Two isolated switches permit the control of two separate circuits e g a local counter and a...

Page 13: ...y for cleanliness Catch filter Syphon refer diagram 5 Interior of bucket Top surface of adjusting screws Enclosure locking screws lightly lubricate after cleaning All insect screens Dismantle Details...

Page 14: ...2022 HyQuest Solutions 14 Maintenance Assembly Details a Screw cap on stem Finger tight only b Push stem into syphon body c Replace nut and tighten Do not over tighten...

Page 15: ...urn shipment 2 Please provide as much information and or clear instructions within the return paperwork This will assist our test engineers with their diagnosis 3 Please do not ship the goods prior to...

Page 16: ...0 01 Series II T Tipping Bucket Rain gauge bucket capacity 0 01inch bucket type Teflon Impregnated injection moulded non hydroscopic plastic ASA UV stabilised TB4 0 5 Series II T Tipping Bucket Rain g...

Page 17: ...ELF TAPPING SCREW 304 PAN HD PHILLIPS STAINLESS STEEL 1 9 TB307 MODEL TB3 RAIN GAUGE 24V REED SWITCH ASSEMBLY 0 5 10 SC023 09 BULL S EYE LEVEL 1 11 SC100 09 SERIAL PLATE 1 12 SC100 06 CALIBRATED LABEL...

Page 18: ...2022 HyQuest Solutions 18 Repair TB4 Series II Bucket Part List...

Page 19: ...2022 HyQuest Solutions 19 Repair Syphon Part List...

Page 20: ...2022 HyQuest Solutions 20 Repair Filter Part List Enclosure Part List...

Page 21: ...2022 HyQuest Solutions 21 Repair Part no Description Quantity TB337 01 Funnel 1 TB337 02 Enclosure 1 TB418 06 Vent 1 SC022 72 Screw 3 TB337 breakdown assembly...

Page 22: ...oated brass Synthetic ceramic coated brass Pivot Bucket Mechanism Machined robust stainless steel axle resting on corrosion free sapphire pivots Enclosure and Base Anodized powder coated aluminium Acc...

Page 23: ...ctions must be observed 8 2 Dismantling Disposal When disposing of the units and their accessories the applicable local regulations regarding environment disposal and occupational safety must be obser...

Page 24: ...re committed to supporting efforts to avoid and recycle waste Please consider Avoidance before recycling Recycling before disposal This symbol indicates that the scrapping of the unit must be carried...

Page 25: ...S Group HyQuest Solutions KISTERS LATAM HyQuest Solutions NZ Ltd HyQuest Solutions Pty Ltd HyQuest Solutions KISTERS AG 1 561 459 4876 sales hsa kisters net 57 350 575 4079 sales latam hyquestsolution...

Page 26: ...www hyquestsolutions com 2022 HyQuest Solutions 21 04 2022...

Reviews: