Comms
The comms configuration menu is the starting point for configuring all iRIS communication settings:
6.3.3.1
Addressing
Serial Number as Address:
Tick this checkbox if you want the address to be obtained automatically from the device's serial number.
Base Address:
Address of the base station to use when calling back using the RS232 telemetry mode. The base address is
normally set to zero.
If the unit will be expected to call back to HydroTel via a gateway site elsewhere, the base address
will need to be set to a suitable value (normally the gateway setting in the gateway logger). If the
base address is left set to zero in this situation, call-backs will fail.
Address Offset:
If the 'Use serial number as address' check box is enabled, then an optional offset can be entered which can
be used to categorise units into regions.
Gateway Offset:
Use 0 to disable gateway communication. If this is not zero, then a gateway block of 100 locations is set up
starting from the offset.