9

Installation

2

Installation

1. Unpack the HailSens IoT from its transport container
2. Check completeness of the delivery
3. Mount the HailSens IoT
4. For wireless communication: insert data SIM
5. Power up the HailSens IoT
6. The sensor starts working

2.1

HailSens IoT: Mechanical Dimensions

Figure 2 – Dimensions in mm

2.2

Pole Mounting

HailSens IoT is delivered with a pole mount bracket and bolts and washers.

Figure 3 – HailSens IoT Pole Mount Bracket with Bolts and Washers

The pole mount bracket is designed for poles of a diameter between 1.5” and 4”.

Summary of Contents for HailSens IoT

Page 1: ...HailSens IoT User Manual 08 2022 01 00 000...

Page 2: ...e Connection 10 2 5 1 Connecting the Ethernet cable 11 2 6 For Wireless Data Communication Insert SIM Card 12 Part III Configuration 13 3 1 LTE M Wireless Data Transmission MOBILE COMMS 15 3 2 Etherne...

Page 3: ...esolve the problem The software programs described in this document and the information contained in this document are confidential and proprietary products of HyQuest Solutions or its licensors HyQue...

Page 4: ...ining the electrical characteristics of drivers and receivers for use in serial communications systems using balanced signals over differential line RS485 does not define a protocol but an electrical...

Page 5: ...2022 HyQuest Solutions 5 III Scope of Delivery Hail Sensor IoT pre mounted unit Power connection cable M12 4 pin Pole mounting bracket FAT document 2022 HyQuest Solutions 5...

Page 6: ...d before starting to work as well as for defects found while working Do not use the HyQuest Solutions HailSens IoT in areas where there is a danger of explosion The present user manual specifies envir...

Page 7: ...uires to be grounded This is required to provide a reliable means to safely conduct the voltages imposed by lighting line surges or un intentional contact with high voltage lines or equipment to groun...

Page 8: ...ties It is operated on 12 VDC The sensor records individual hail impacts It measures the kinetic energy of each impact Apart from initial setup and periodic maintenance once a year right before the ha...

Page 9: ...communication insert data SIM 5 Power up the HailSens IoT 6 The sensor starts working 2 1 HailSens IoT Mechanical Dimensions Figure 2 Dimensions in mm 2 2 Pole Mounting HailSens IoT is delivered with...

Page 10: ...avoid cluttering in snow during the winter period 2 4 Electrical Bonding Earth The electronics box is equipped with an M6 earth stud The position of the Earth stud is shown in the following figure Th...

Page 11: ...able with a waterproof cable gland Two caps are delivered The round closing cap is used as along as no cable is fitted Waterproof and weatherproof CAT6 RJ45 jack with RJ45 jack at the back RJ45 pass t...

Page 12: ...ireless Data Communication Insert SIM Card A SIM card must be inserted into the SIM Card Slot of the integrated data logger data modem unit Unscrew the lid 4 screws and remove it Insert the SIM Make s...

Page 13: ...Configuration Dialogue The Network settings only apply to the Ethernet port and do not affect the USB based network connection The parameters that can be edited by the user are listed and briefly expl...

Page 14: ...Authentication Authentication Method Connection Retries Connection Retries Connection Error Timeout Connection Error Timeout STATIC COMMS IP Adress Fixed IP Adress or address obtained by DHCP NetMask...

Page 15: ...ccording to the contract plan you have with your network operator If APN setup has not yet been performed on the communication device be sure to perform APN registration For details see figure in topi...

Page 16: ...l supply voltage is 12 VDC For the entire voltage range see the Data Sheet The sensor is delivered without a power supply Potential power supplies are 12V 1 Amp DC power supplies solar power unit with...

Page 17: ...are clearly inside the plate will impact the measurement The transducer unit must be replaced Spare parts can be ordered separately HailSens Transducer Spare Part Article Number MON11_SMATRSCHSTRDCR 5...

Page 18: ...2022 HyQuest Solutions 18 Troubleshooting 6 Troubleshooting In case the sensor does not work as expected please contact the distributor or the manufacturer...

Page 19: ...ur return shipment 2 Please provide as much information and or clear instructions within the return paperwork This will assist our test engineers with their diagnosis 3 Please do not ship the goods pr...

Page 20: ...llet kinetic energy pellet equivalent diameter calibration factor Heartbeat user configurable default every 6h Measurement data 1 data package per impact Local Communication Micro USB Housing Aluminiu...

Page 21: ...unsorted municipal waste This applies in particular to electrical waste and old electronic equipment Electrical waste and electronic equipment must not be disposed of as household waste Instead these...

Page 22: ...uest Solutions Pty Ltd HyQuest Solutions KISTERS AG 49 2408 9385 0 info hyquestsolutions eu www hyquestsolutions eu 612 9601 2022 sales hyquestsolutions com au www hyquestsolutions com au 64 7 857 081...

Page 23: ...www hyquestsolutions com 2022 HyQuest Solutions 05 10 2022...

Reviews: