Hypex Electronics UcD700 Assembly Instructions Manual Download Page 1

Mono kit

®

Assembly

Instructions

Summary of Contents for UcD700

Page 1: ...Mono kit Assembly Instructions...

Page 2: ...hnology Please note the different models This assembly instruction describes how to assemble one of these models Both models only offer balanced inputs If your source only offers unbalanced outputs yo...

Page 3: ...appliance coupler is used as the disconnect device so the disconnect device shall remain readily operable 19 Do not run any cables across the top or the bottom of the module Apply xtures to cables to...

Page 4: ...4 6x Not used AM 2 2x M4x10 H01U000720 AM 1 1x UcD700HG with HxR Ampli er H02U004320 SU 1 1x SMPS1200A700 Supply Parts hot glue 2 5mm 12mm OR TX 20 5 5mm 7mm 3 5mm PH 2 PH 1 Tools not included...

Page 5: ...AS 13 1x Z1A11L1 AS 12 1x Z1A2L1 AS 11 1x Z1A10L4 AS 10 1x AS 9 1x M11G004960 AS 8 3x F06G004994 F06G000050 AS 7 7x P02U005937 AS 6 1x P02U005936 AS 5 1x AS 4 1x E14U001062 AS 3 1x T12A 250V T12A 250V...

Page 6: ...3mm CA 21 4 5mm 1x CA 20 M4 1x CA 19 1x M4x12 CA 18 M4x10 4x CA 17 M4x10 4x CA 16 2x 3 3mm CA 15 2x M3 CA 14 M3x10 2x CA 13 M3x8 6x CA 12 4x M3x7 CA 11 M3x6 2x CA 10 M3x5 2x CA 9 1x 1 5mm 4xCA 8 2x C...

Page 7: ...7 Assembly 230Vac Mains 115Vac Mains Result...

Page 8: ...E DE CHOC LECTRIQUE NE PAS OUVRIR T U P T U O I N PUT AS 14 AS 10 AS 6 AS 5 AS 4 AS 3 T12A 250V T12A 250V AS 2 AS 1 CA 16 2x CA 15 2x CA 14 2x CA 4 FUSE T5AH 250V 350W Max 50Hz 60Hz 100 120V 200 240V...

Page 9: ...U P T U O I N PUT 2x 2x FUSE T5AH 250V 350W Max 50Hz 60Hz 100 120V 200 240V CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN PRECAUTION RISQUE DE CHOC LECTRIQUE NE PAS OUVRIR T U P T U O I N PUT FUSE T5AH...

Page 10: ...CA 12 4x CA 8 4x CA 1 SU 1 AS 8 2x Supply Feet FUSE T5AH 250V 350W Max 50Hz 60Hz 100 120V 200 240V CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN PRECAUTION RISQUE DE CHOC LECTRIQUE NE PAS OUVRIR T U P T...

Page 11: ...11 7 2 1 CA 6 CA 22 CA 21 CA 20 CA 19 CA 11 2x AS 12 Light Ground 2 5...

Page 12: ...lue AS 13 J8 AS 17 AS 14 FUSE T5AH 250V 350W Max 50Hz 60Hz 100 120V 200 240V CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN PRECAUTION RISQUE DE CHOC LECTRIQUE NE PAS OUVRIR TUPTUO I N P U T AS 13 AS 9 AM...

Page 13: ...13 a little bit of thermal paste Vcc Gnd Vee Vdr AS 17...

Page 14: ...350W Max 50Hz 60Hz 100 120V 200 240V CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN PRECAUTION RISQUE DE CHOC LECTRIQUE NE PAS OUVRIR T U P T U O I N PUT 2 2x Female XLR micro t AS 8 Cablemount Backpanel...

Page 15: ...15 J1 AS 7 2x Main DC cable J5 CA 5 AS 7 2x In Out cable Light cable...

Page 16: ...16 J10 J4 AS 16 AS 7 Interface...

Page 17: ...17 J2 AS 7 2x AS 15 SMPS AC...

Page 18: ...ISK OF ELECTRIC SHOCK DO NOT OPEN PRECAUTION RISQUE DE CHOC LECTRIQUE NE PAS OUVRIR T U P T U O I N PUT 2 2x Check all connections before proceeding page 7 CA 23 2x CA 18 2x CA 2 Lid J3 230Vac Mains J...

Page 19: ...19 1 5 2 2x CA 23 4x CA 9 CA 7 2x CA 3 CA 10 2x CA 17 4x Front...

Page 20: ...20 2x...

Page 21: ...mpedance 100k Either input to ground Power Bandwidth 20 35kHz Frequency Response 10Hz 50kHz Operation 20m f 1kHz Performance 150m f 20kHz For more detailed information please refer to the datasheet of...

Page 22: ...speakers For best results we recommend using our NC400 mono kits with electrostatic speakers I do not have any technical experience can I Q build this ampli er kit myself Can I drive electrostatic lou...

Page 23: ...rtain to this DIY ampli er kit only Disclaimer If you discover a defect notify DIYClassD com during the warranty period Claims under warranty must be supported by reasonable evidence that the date of...

Page 24: ...DIYClassD com Kattegat 8 9723 JP Groningen The Netherlands 31 50 526 4993 sales diyclassd com www diyclassd com...

Reviews: