Qualifications and Requirements
2
56
809480
Instruction Manual
XPR300
Bend radius requirements for hoses, cables, and leads
The following hoses, cables, and leads cannot bend beyond a
minimum bend radius of 15.25 cm (6 inches):
Pilot arc lead
Coolant hose set
Power cable
CAN cable
3-gas hose bundle for the
Core
gas connect console
5-gas hose bundle for the
VWI or OptiMix gas
connect
console
Gas supply hoses
Distance requirements between high-frequency leads and control cables
Interference and electrical noise can occur if high-frequency leads (such as the pilot arc and
negative leads) are too close to control cables (such as the 120 VAC power, CAN, and EtherCAT
®
cables).
If possible, use a separate track to isolate each lead and cable.
If separate tracks are not possible, Hypertherm recommends a minimum separation distance
150 mm (6 inches) between the high-frequency leads and control cables. Separate the pilot arc
lead, negative lead, or any power cables that have a voltage higher than 120 VAC from the
following:
CAN cable
Power cable (120 VAC)
CNC lead (EtherCAT, serial RS-422, or discrete lead)
Distance requirements for ventilation and access
Ventilation
Do not block the ventilation louvers on the corners or bottom panels of the front and
back of the plasma power supply. A separation distance of least 1 m (3.3 feet) is
required for ventilation.
Do not block the ventilation louvers on the gas connect console. A separation distance
of least 1.27 cm (0.50 inch) is required for ventilation.
Do not block the ventilation louvers on the torch connect console. You must use the
mounting brackets to allow space between the console and mounting surface.
Service and maintenance access – Hypertherm recommends a minimum distance of
1 meter (3.3 feet) between the plasma power supply and other system components, or
between the plasma power supply and an obstacle.
15.25 cm
(6 in.)
Minimum bend radius
(measured inside diameter)
Summary of Contents for XPR300
Page 1: ...XPR300 Plasma Instruction Manual 809480 Revision 2 English ...
Page 18: ...Contents 18 809480 Instruction Manual XPR300 ...
Page 34: ...Specifications 1 34 809480 Instruction Manual XPR300 ...
Page 66: ...Qualifications and Requirements 2 66 809480 Instruction Manual XPR300 ...
Page 188: ...Connect for Communication 4 188 809480 Instruction Manual XPR300 ...
Page 192: ...Coolant Installation 5 192 809480 Instruction Manual XPR300 ...
Page 230: ...Operation 6 230 809480 Instruction Manual XPR300 ...
Page 337: ...Parts List 9 XPR300 Instruction Manual 809480 337 ...
Page 343: ...Parts List 9 XPR300 Instruction Manual 809480 343 ...
Page 380: ...Wiring Diagrams 10 380 809480 Instruction Manual XPR300 ...
Page 381: ...381 Overview Sheet 1 of 22 013403 013403 ...
Page 382: ...382 Plasma power supply 1 Sheet 2 of 22 013403 ...
Page 383: ...383 Plasma power supply 2 Sheet 3 of 22 013403 ...
Page 384: ...384 Plasma power supply 3 Sheet 4 of 22 013403 ...
Page 385: ...385 Plasma power supply 4 Sheet 5 of 22 013403 ...
Page 386: ...386 Plasma power supply 5 Sheet 6 of 22 013403 ...
Page 387: ...387 Plasma power supply 6 Sheet 7 of 22 013403 ...
Page 388: ...388 Plasma power supply 7 Sheet 8 of 22 013403 ...
Page 389: ...389 Gas connect console 1 Sheet 9 of 22 013403 ...
Page 390: ...390 Gas connect console 2 Sheet 10 of 22 013403 ...
Page 391: ...391 Torch connect console Sheet 11 of 22 013403 ...
Page 392: ...392 Coolant system Sheet 12 of 22 013403 ...
Page 393: ...393 Gas system 1 Sheet 13 of 22 013403 ...
Page 394: ...394 Gas system 2 Sheet 14 of 22 013403 ...
Page 395: ...395 Gas system 3 Sheet 15 of 22 013403 ...
Page 402: ...402 Wireless subsystem block diagram Sheet 22 of 22 013403 ...