Page 1b-4
THC-2 Torch Height Control
INSTALLATION - MAX200
INSTALL INTERCONNECT CABLE TO MAX200
Strain Relief
R4
TB4
TB3
Figure 1b-3 Inside Rear of MAX200 Power Supply
1.
Connect the interface cable to RECP2 on the THC-2 module.
2.
Loosen the adjustable strain relief on the rear of the MAX200 power supply - Fig. 1b-3.
3.
Thread the other end of the interface cable through this strain relief and make
connections to TB4, TB3 (Fig. 1b-3) and voltage divider as shown in the Figure 1b-4
wiring diagram. Note: Push wires labeled 42 and 70 through the center wall feed-thru to
get to voltage divider.
4.
Connect the white wire from the voltage divider to location #45 on R4 which is located on
the left rear wall of the MAX200 power supply - Fig. 1b-4.
This completes installation of the THC-2 to the MAX200. See Section 2 for operation
instructions.