Fault code and LED behavior
On the plasma power supply:
When you start the plasma power supply while the torch-lock switch is in
the yellow lock (
X
) position, the system shows the
0-50-0
fault code
instead of
0-50-1
. Move the torch-lock switch to the green “ready to fire”
(
) position to continue.
On the SmartSYNC hand torch:
1
2
3
Yellow
Yellow
Green
When you set the torch-lock switch to the yellow lock (
X
) position while the plasma power supply
stays ON, the Fault light-emitting diode (LED) comes on and the
0-50-1
fault code and Torch Cap
Sensor icon show.
After you install the cartridge and set the torch-lock switch to the green “ready to fire” (
)
position, the Fault LED goes off and the fault code changes to
0-50-2
.
Hand torch:
After the torch puts out the warning puffs of air, the 0-50-2 fault code goes off.
Machine torch:
The 0-50-2 fault code shows for approximately 1 second and then goes off.
When you set the torch-lock switch to the yellow lock (
X
) position while the plasma power supply
stays ON, the LED on the hand torch changes from green to
yellow
.
When you install the Hypertherm cartridge and set the torch-lock switch to the green “ready to
fire” (
) position, the LED on the hand torch stays
yellow
.
After the torch puts out the warning puffs of air, the LED changes from yellow to
green
.
1
2
3
1
2
3
Summary of Contents for SYNC Powermax 105
Page 1: ...Powermax65 85 105 SYNC Operator Manual 810470 REVISION 3 ENGLISH ...
Page 8: ......
Page 14: ...Contents 14 810470 Operator Manual Powermax65 85 105 SYNC ...
Page 20: ...Where to Find Information 1 20 810470 Operator Manual Powermax65 85 105 SYNC ...
Page 62: ...Install and Set Up the Plasma Power Supply 2 62 810470 Operator Manual Powermax65 85 105 SYNC ...
Page 94: ...Operate the Plasma System 3 94 810470 Operator Manual Powermax65 85 105 SYNC ...