![Hypertherm powermax900 Service Manual Download Page 52](http://html1.mh-extra.com/html/hypertherm/powermax900/powermax900_service-manual_2193783052.webp)
3-25
M
AINTENANCE
Service Manual
Figure 3-16 Control Board LED Locations
J8
J1
J3
J4
J7
J6
J5
TP5 (Gnd)
J2
LED3
LED1
LED4
R1
LED2
LED5
LED6
LED7
LED8
LED9
LED10
LED11
LED12
LED13
LED14
S1
9-99
The control board also controls the sequence required to generate plasma:
•
Turns on the inverter approximately 1 second after the torch trigger switch is pressed
•
After a short delay, turns on the gas solenoid valve V1 to blow back the electrode
•
Monitors the pilot arc for arc transfer
•
Ramps the current control command from the pilot arc level (22 amps) to the cut current selected by the
operator
•
Turns the inverter off if the output current fails for any reason
•
Turns the inverter off if the torch blow back does not occur within 2 seconds
•
Turns off the power supply when the retaining cap is loose or when line voltage is too high.
•
LED6 PLASMA START: Illuminates when the torch start button is pushed or when start
button is activated from the machine interface.
•
LED7 INVERTER ON: Illuminates when the command to turn on the inverter modulator is
given.
•
LED8 CURRENT: Illuminates when current greater than 10 amps is detected in electrode
circuit.
•
LED9 BLOWBACK: Illuminates when more than 25 arc volts is detected.
•
LED10 ARC TRANSFER: Illuminates when arc transfers to the workpiece (when arc current
is greater than 1.5 amps).
•
LED12 OVERCURRENT: Illuminates when CS1 or CS2 senses current above 70 amps.
Release the START switch to clear.
•
LED13 FAULT: Illuminates when there is either an overvoltage condition, an imbalance in the
inverters, or a micro-controller failure.
Summary of Contents for powermax900
Page 1: ...EN50199 EN50192 Plasma Arc Cutting System Service Manual 803150 Revision 3 ...
Page 9: ...TABLE OF CONTENTS Service Manual vi ...
Page 15: ...SAFETY 1 6 Hypertherm Plasma Systems 8 99 ...
Page 21: ...SÉCURITÉ 1a 6 08 99 HYPERTHERM Systèmes plasma ...
Page 48: ...3 21 MAINTENANCE Service Manual Notes ...
Page 69: ...4 12 Service Manual PARTS LIST 208 240 480V ...
Page 81: ...5 12 Service Manual PARTS LIST 200 230 400V ...
Page 93: ...6 12 Service Manual PARTS LIST 400V CE ...
Page 99: ...7 6 Service Manual PARTS LIST TORCH AND CONSUMABLES ...
Page 101: ...8 2 E ELEC SCHEM PMX900 208 240 480V 013 3 326 1 OF 1 ...
Page 102: ...8 3 E ELEC SCHEM PMX900 200 230 400V 013 3 328 1 OF 1 ...
Page 103: ...8 4 E ELEC SCHEM PMX900 CE 400V 013 3 327 1 OF 1 ...