background image

Plasma Arc
Cutting System

Operator Manual
803390  Revision 3

powermax

600

®

Summary of Contents for powermax600

Page 1: ...Plasma Arc Cutting System Operator Manual 803390 Revision 3 powermax600 ...

Page 2: ... Hypertherm Inc All Rights Reserved Hypertherm and Powermax are trademarks of Hypertherm Inc and may be registered in the United States and or other countries Revision 3 November 2013 Hypertherm Inc Hanover NH USA http www hypertherm com email info hypertherm com powermax600 ...

Page 3: ...2490 Fax 65 6 841 2489 Technical Service Japan 1952 14 Yata Natsumegi Mishima City Shizuoka Pref 411 0801 Japan 81 0 559 75 7387 Tel 81 0 559 75 7376 Fax Hypertherm UK Ltd 9 Berkeley Court Manor Park Runcorn Cheshire England WA7 1TQ 44 1928 579 074 Tel 44 1928 579 604 Fax France 15 Impasse des Rosiers 95610 Eragny France 00 800 3324 9737 Tel 00 800 4973 7329 Fax Hypertherm S r l Via Torino 2 20123...

Page 4: ...nnection to the workpiece but in some countries where direct connection is not permitted the bonding should be achieved by suitable capacitances selected according to national regulations Note The cutting circuit may or may not be earthed for safety reasons Changing the earthing arrangements should only be au thorized by a person who is competent to assess whether the changes will increase the ris...

Page 5: ...herm PATENT INDEMNITY Except only in cases of products not manufactured by Hypertherm or manufactured by a person other than Hypertherm not in strict conformity with Hypertherm s specifications and in cases of designs processes formulae or combinations not developed or purported to be developed by Hypertherm Hypertherm will defend or settle at its own expense any suit or proceeding brought against...

Page 6: ...e les instructions de sécurité 1a 2 Le coupage peut provoquer un incendie ou une explosion 1a 2 Les chocs électriques peuvent être fatals 1a 3 Le coupage peut produire des vapeurs toxiques 1a 3 L arc plasma peut provoquer des blessures ou des brûlures 1a 4 Mise à la masse et à la terre 1a 4 Les rayons de l arc peuvent brûler les yeux et la peau 1a 4 Sécurité des bouteilles de gaz comprimé 1a 5 Les...

Page 7: ... Parts Routine maintenance 5 2 Inspect consumables 5 3 Torch lead replacement 5 5 Work cable replacement 5 6 Power cord replacement 5 7 Air filter element replacment 5 8 Basic Troubleshooting 5 10 Technical Questions 5 10 Parts 5 14 Torch consumables See Section 4 PAC123T hand torch assembly No Q disc 5 14 PAC123T hand torch assembly With Q disc 5 16 PAC123M machine torch assembly No Q disc 5 18 P...

Page 8: ...n Kill 1 3 Cutting Can Produce Toxic Fumes 1 3 A Plasma Arc Can Cause Injury and Burns 1 4 Arc Rays Can Burn Eyes and Skin 1 4 Grounding Safety 1 4 Compressed Gas Equipment Safety 1 5 Gas Cylinders Can Explode If Damaged 1 5 Noise Can Damage Hearing 1 5 Pacemaker and Hearing Aid Operation 1 5 A Plasma Arc Can Damage Frozen Pipes 1 5 Additional Safety Information 1 5 Warning Label 1 6 ...

Page 9: ...e the area is safe before doing any cutting Keep a fire extinguisher nearby Remove all flammables within 35 feet 10 m of the cutting area Quench hot metal or allow it to cool before handling or before letting it touch combustible materials Never cut containers with potentially flammable materials inside they must be emptied and properly cleaned first Ventilate potentially flammable atmospheres bef...

Page 10: ...le you cut Leave the workpiece in place or on the workbench with the work cable attached during the cutting process Before checking cleaning or changing torch parts disconnect the main power or unplug the power supply Never bypass or shortcut the safety interlocks Before removing any power supply or system enclosure cover disconnect electrical input power Wait 5 minutes after disconnecting the mai...

Page 11: ...ly Tighten all electrical connections to avoid excessive heating Eye Protection Plasma arc rays produce intense visible and invisible ultraviolet and infrared rays that can burn eyes and skin Use eye protection in accordance with applicable national or local codes Wear eye protection safety glasses or goggles with side shields and a welding helmet with appropriate lens shading to protect your eyes...

Page 12: ...g of Containers and Piping That Have Held Hazardous Substances American Welding Society 550 LeJeune Road P O Box 351040 Miami FL 33135 5 AWS F5 2 Recommended Safe Practices for Plasma Arc Cutting American Welding Society 550 LeJeune Road P O Box 351040 Miami FL 33135 6 CGA Pamphlet P 1 Safe Handling of Compressed Gases in Cylinders Compressed Gas Association 1235 Jefferson Davis Highway Arlington ...

Page 13: ... path 2 3 Wear complete body protection 3 Electric shock from torch or wiring can kill Protect yourself from electric shock 3 1 Wear insulating gloves Do not wear wet or damaged gloves 3 2 Insulate yourself from work and ground 3 3 Disconnect input plug or power before working on machine 4 Breathing cutting fumes can be hazardous to your health 4 1 Keep your head out of the fumes 4 2 Use forced ve...

Page 14: ...vention des chocs électriques 1a 3 Le coupage peut produire des vapeurs toxiques 1a 3 L arc plasma peut provoquer des blessures ou des brûlures 1a 4 Torches à allumage instantané 1a 4 Les rayons de l arc peuvent brûler les yeux et la peau 1a 4 Protection des yeux Protection de la peau Zone de coupage 1a 4 Mise à la masse et à la terre 1a 4 Câble de retour Table de travail Alimentation 1a 4 Sécurit...

Page 15: ...ne sont pas suivies correctement Prévention des incendies Avant de commencer s assurer que la zone de coupage ne présente aucun danger Conserver un extincteur à proximité Éloigner toute matière inflammable à une distance d au moins 10 m du poste de coupage Tremper le métal chaud ou le laisser refroidir avant de le manipuler ou avant de le mettre en contact avec des matériaux combustibles Ne jamais...

Page 16: ...lors du coupage Laisser la pièce à couper en place ou sur la table de travail le câble de retour connecté lors du coupage Avant de vérifier de nettoyer ou de remplacer les pièces de la torche couper l alimentation ou débrancher la prise de courant Ne jamais contourner ou court circuiter les verrouillages de sécurité Avant d enlever le capot du système ou de la source de courant couper l alimentati...

Page 17: ... de l arc plasma produisent de puissants rayons visibles ou invisibles ultraviolets et infrarouges qui peuvent brûler les yeux et la peau Utiliser des lunettes de sécurité conformément aux codes locaux ou nationaux en vigueur Porter des lunettes de protection lunettes ou masque muni d écrans latéraux et encore masque de soudure avec des verres teintés appropriés pour protéger les yeux des rayons u...

Page 18: ...e jamais exposer des bouteilles à une chaleur excessive aux étincelles aux scories ou aux flammes nues Ne jamais utiliser des marteaux des clés ou d autres outils pour débloquer le robinet des bouteilles Une exposition prolongée au bruit du coupage ou du gougeage peut provoquer des problèmes auditifs Utiliser un casque de protection homologué lors de l utilisation du système plasma Prévenir les pe...

Page 19: ...t être fatal Se protéger contre les risques de chocs électriques 3 1 Porter des gants isolants Ne pas porter de gants mouillés ou abîmés 3 2 S isoler de la surface de travail et du sol 3 3 Débrancher la prise ou la source de courant avant de manipuler l équipement 4 L inhalation des vapeurs produites par le coupage peut être dangereuse pour la santé 4 1 Garder le visage à l écart des vapeurs 4 2 U...

Page 20: ...powermax600 Operator Manual 2 1 0 Section 2 SPECIFICATIONS In this section Specifications Power Supply 2 2 Specifications PAC123 Torches 2 3 Symbols and Markings 2 4 ...

Page 21: ...C 14 to 104 F Apparent Input Power S1 230 400 V 6 7 kVA 208 240 480 V 9 5 kVA Input Voltage U1 Input Current I1 at 230 V 17 A 3 phase 50 60 Hz CE 5 6 kW Output 400 V 9 7 A 3 phase 50 60 Hz CE 208 240 V 40 46 A 1 phase 50 60 Hz CSA NRTL 480 V 12 A 3 phase 50 60 Hz CSA NRTL Gas Type Air Nitrogen Gas Quality Clean dry oil free 99 995 pure Gas Inlet Pressure and Flow See Section 3 Setup PMX600 14 Powe...

Page 22: ...g metal removal rate hour Weight 3 5 pounds 1 6 kg with 15 ft 4 5 m lead PAC123T 4 5 pounds 2 kg with 25 ft 7 5 m lead 7 pounds 3 2 kg with 50 ft 15 m lead 6 pounds 2 7 kg with 15 ft 4 5 m lead PAC123M 7 pounds 3 2 kg with 25 ft 7 5 m lead 9 5 pounds 4 3 kg with 50 ft 15 m lead PAC123T Hand Torch Dimensions PAC123M Machine Torch Dimensions PAC123T PAC123T 04 PAC123M 07 8 72 221 mm 8 5 216 mm 15 06...

Page 23: ...able parts to maintain S mark compliance IEC Symbols Used The following symbols may appear on the power supply data plate control labels and switches Direct Current DC The terminal for the external protective earth conductor AC input power connection Plasma torch cutting and gouging Alternating current AC An inverter based power source Volt amp curve drooping characteristic Power is off Power is o...

Page 24: ...powermax600 Operator Manual 3 1 Section 3 SETUP In this section Lifting Power Supply 3 2 Power Hookup 3 2 Torch Hookup Quick Disconnect Only 3 5 Gas Hookup 3 5 PAC123M Machine Torch Setup 3 7 ...

Page 25: ...upply by ONE handle The handle can break resulting in injury and damage to the power supply Power Hookup Check Required Input Voltage Look at U1 on the data plate to check input voltage requirements The data plate is on the back of the power supply 54 lb 25 kg Hoist Cover in place Approved hoisting strap Keep as vertical as possible ...

Page 26: ...or local codes The cord should be installed by a licensed electrician Refer to the length requirements listed below 10 ft 10 25 ft 25 50 ft 50 100 ft 100 150 ft 3 m 3 7 5 m 7 5 15 m 15 30 m 30 45 m Input Voltage Phase Recommended Cord Gauge Size mm2 208 240 VAC 1 10 10 10 16 16 230 VAC 3 4 6 6 10 10 400 VAC 3 2 5 2 5 4 6 6 480 VAC 3 4 4 4 4 6 Recommended Cord Gauge Size AWG 208 240 VAC 1 8 8 8 6 6...

Page 27: ...erly grounded through the power cord according to national or local electrical codes Three phase service must use a 4 wire cord that includes a protective earth ground Also see Grounding Safety in Section 1 of this manual Generator Power When using a generator to power the Powermax600 Use a generator with a minimum auxiliary output of 8 kVA The generator must be dedicated to powering the plasma cu...

Page 28: ... damage the power supply torch and consummables The power supply will not power up if the gas inlet pressure is below minimum CAUTION Do not exceed 120 psi 8 3 bar pressure at the power supply gas inlet Damage to system may result from higher pressures Torch Hookup For models with quick disconnect Install torch lead to power supply PMX600 06 Key way Before tightening align threads by turning one t...

Page 29: ...rogen to the power supply gas inlet Apply liquid pipe sealant to the threads to ensure a leak free installation CAUTION Do not use PTFE tape on pipe threads Pieces of tape can enter the air line and damage the system 90 psi 6 2 bar 208 240 480V PMX600 11 90 psi 6 2 bar 230 400V Shipped with these parts installed 10 99 ...

Page 30: ...endant PAC123M ON OFF Pendant Connection PAC123M Torch Alignment Mount the machine torch perpendicular to the workpiece in order to get a vertical cut Use a square to align the torch at 0 and 90 PAC123M Machine Torch Setup Socket A White Wire Socket B Not Used Socket C Black Wire Torch 0 90 ...

Page 31: ...SETUP 3 8 powermax600 Operator Manual ...

Page 32: ... Indicators 4 2 Confirm Torch Consumables 4 3 installing Torch Consumables 4 4 Pilot Arc ControlSswitch 208 240 480 Volt Only 4 5 Turn On Power 4 5 Check Indicator Lights 4 5 Adjust Gas Pressure and Current Setting 4 6 Hand Torch Operation 4 7 Machine Torch Operation 4 12 Cut Chart 4 12 ...

Page 33: ...00 Operator Manual PMX600 05 ON OFF Controls and Indicators Current Amps Adjustment Knob Indicator Lamps Pressure Gauge Power Lamp See Section 5 Ready Lamp ON I OFF 0 Switch Pressure Regulator Pilot Arc Control Switch 208 240 480 V ...

Page 34: ...ting Unshielded 120827 120600 120826 Deflector 120574 120303 120600 120606 Hand Cutting Gouging 120828 120600 120826 Shield Retaining Cap Nozzle 120573 120576 Electrode Swirl Ring 120608 120600 120831 In CE countries unshielded consumables may only be used in machine torch applications ...

Page 35: ...PLASMA ARC CAN CAUSE INJURY AND BURNS Plasma arc comes on immediately when the torch switch is activated The plasma arc will quickly cut through gloves and skin Make sure power is off before changing consumables Installing Torch Consumables Hand tighten only Hand tighten only ...

Page 36: ...illuminated Check Indicator Lights Check that the remaining indicator lamps are NOT illuminated See Section 5 for details PMX600 07A Pilot Arc Control Switch 208 240 480 Volt Only Use to cut expanded metal Automatically reinitiates pilot Use to cut plate sheet metal Optimum consumable life Check that the OK lamp is illuminated ...

Page 37: ...correct gas pressure is set proceed to If the gas pressure requires adjustment proceed to Adjust Gas Pressure and Current Setting Pull the regulator knob up to unlock Turn the regulator knob to obtain the correct pressure Turn the current adjustment knob to the desired amps setting 40 15 ft 4 5 m 50 ft 15 m 25 ft 7 5 m 72 psi 5 0 BAR 72 psi 5 0 BAR 78 psi 5 4 BAR 60 psi 4 2 BAR 55 psi 3 8 BAR 50 p...

Page 38: ...es on immediately when the torch switch is activated The plasma arc will quickly cut through gloves and skin Keep away from the torch tip Do not hold the workpiece and keep your hands clear of the cutting path Never point the torch toward yourself or others Safety Trigger Operation Avoid firing the torch when it is not in contact with the workpiece ...

Page 39: ...ch nozzle at a vertical position and watch the arc as it cuts along the line Shielded Consumables Do not push down on the torch when cutting Lightly drag the torch across the workpiece to maintain a steady cut Pulling the torch through the cut is easier than pushing it To cut thin material reduce the amps until you get the best quality cut For straight line cuts use a straight edge as a guide To c...

Page 40: ...ossible to the area being cut to reduce exposure to electromagnetic fields EMF Do not attach it to the portion that will fall away Starting a Cut from the Edge of the Workpiece Hold the torch nozzle vertical at the edge of the workpiece Start cutting from the edge of the workpiece Pause at the edge until the arc has completely cut through the workpiece Then proceed with the cut Attach the Work Cla...

Page 41: ... Point the torch away from yourself and others Piercing Hold the torch so that the nozzle is within 1 16 inch 1 5 mm from the workpiece before firing the torch Fire the torch at an angle to the workpiece then slowly rotate it to an upright position When sparks are exiting from the bottom of the workpiece the arc has pierced through the material When the pierce is complete proceed with the cut ...

Page 42: ... the trigger to transfer the arc Rotate the torch to 45 from the workpiece Feed into the gouge WARNING SPARKS AND HOT METAL CAN INJURE EYES AND BURN SKIN When firing the torch at an angle sparks and hot metal will spray out from the nozzle Point the torch away from yourself and others Direction of travel 45 ...

Page 43: ...teel 40 120 140 4950 0 5 1 4 6 Mild Steel 40 130 55 1680 1 0 3 8 10 Mild Steel 40 140 27 640 1 2 13 Mild Steel 40 140 19 460 5 8 16 Mild Steel 40 150 10 250 0 020 1 Aluminum 20 170 175 4150 0 0 060 1 5 Aluminum 20 170 125 3330 0 16 ga 1 5 Aluminum 40 130 420 10900 0 1 8 3 Aluminum 40 135 140 4450 0 5 1 4 6 Aluminum 40 140 53 1620 1 0 3 8 10 Aluminum 40 150 25 510 1 2 13 Aluminum 40 150 17 410 5 8 ...

Page 44: ...c Troubleshooting 5 10 Technical Questions 5 10 Parts 5 14 Torch Consumables See Section 4 PAC123T Hand Torch Assembly No Quick Disconnect 5 14 PAC123T Hand Torch Assembly With Quick Disconnect 5 16 PAC123M Machine Torch Assembly No Quick Disconnect 5 18 PAC123M Machine Torch Assembly With Quick Disconnect 5 20 Power Supply Filter Regulator 5 22 Power Supply Work Cable 5 22 Powermax600 Labels 5 23...

Page 45: ...cian Each Use Check gas pressure Replace damaged power cord or plug Replace damaged torch lead Check pressure hose and connections for leaks Clean the inside of the power supply with air pressure or vacuum Replace damaged labels Check torch cap on safety switch listen for click when the retaining cap is loosened Check consumables for proper installation and wear Check trigger for damage Check torc...

Page 46: ...in through blocked hole from the inside Center hole Round Hole must be round Replace Signs of arcing None Replace Nozzle tip Nozzle Even wear or erosion 1 32 inch 1 mm minimum remaining Replace Side wear or erosion None Replace Center hole Round View from inside Hole must be round Replace Center surface Electrode Wear Pit not more than 1 16 inch 1 6 mm deep Replace o o Max 1 6 mm External surfaces...

Page 47: ...bles Continued External surfaces Damage or debris Clean and no damage Replace Edge gas holes Blocked holes None Replace External surfaces Damage or wear None Replace Lubricated Not dry Apply a thin film of silicone lubricant Part Check For Limit Action Swirl Ring Torch O ring ...

Page 48: ...ng the old torch lead Installation CAUTION Do not tighten the strain relief collar 4 onto the torch lead until the gas fitting 3 is tight or the gas connection may leak 1 Install the strain relief 1 and secure with nut 2 2 Connect and tighten the gas fitting 3 3 Tighten the strain relief collar 4 onto the lead 4 Connect the electrical connections 5 6 and 7 Tighten the terminal block screws to 10 i...

Page 49: ...hten the strain relief collar 5 onto the cable 5 Connect the work cable to the terminal block 6 Tighten the terminal block screw to 10 in lb 12 kg cm of torque 6 Install the power supply cover Reconnect electrical power and gas supply Work Cable Replacement CAUTION This is a high current connection Proper torque is critical PMX600 15 WARNING ELECTRIC SHOCK CAN KILL Disconnect electrical power befo...

Page 50: ...he power cord 5 Install the power supply cover 6 Reconnect electrical power and gas supply 208V 240V 230V and 400V PMX600 12 480V 230V 400V YELLOW GREEN GREEN BROWN BLUE BLACK BLACK WHITE GREEN BLACK WHITE RED Pass all 4 wires through the toroid 2 times Pass all 4 wires through the toroid 3 times NOTE Toroid must be installed for power supply to be in compliance with EMC standard EN50199 WARNING E...

Page 51: ...rew the filter bowl Do not discard the O ring Remove the filter element from the filter housing NOTE Do not allow the filter element to turn when loosening the screw Removal Disconnect electrical power Disconnect gas supply Remove the power supply cover WARNING ELECTRIC SHOCK CAN KILL Disconnect electrical power before performing any maintenance All work requiring removal of the power supply cover...

Page 52: ...pressure line fully into the hose fitting Install the drain hose into the grommet Install the power supply cover Reconnect electrical power and gas supply Install the new filter element into the filter housing Secure with screw and retainer Install the filter bowl and O ring into the filter housing Installation ...

Page 53: ...d and that all fault conditions are clear none of the yellow lamps are illuminated Yellow LOW LINE VOLTAGE When illuminated indicates that the AC line voltage is 1 below operating limits or 2 is missing 1 phase 230V and 400V systems only Yellow LOW GAS PRESSURE When illuminated indicates that the incoming gas pressure is below operating limits Yellow TORCH PARTS ARE LOOSE OR REMOVED When illuminat...

Page 54: ...ted and the LOW LINE VOLTAGE lamp is illuminated 3 1 Line voltage is too low or a phase is missing The following table lists the operating range of the Powermax600 power supplies Have an electrical technician check incoming power 5 The POWER ON lamp is illuminated and the HIGH TEMPerature lamp is illuminated 5 1 One of the internal thermostat switches has opened due to overheating Leave the power ...

Page 55: ...nsumables See Installing Torch Consumables Section 4 7 The POWER ON lamp is illuminated and the TORCH PARTS LOOSE OR REMOVED lamp is illuminated 7 1 Torch consumables are loose or removed from the torch Turn off power supply and tighten or install torch consumables See Installing Torch Consumables Section 4 If the torch consumables become loose or were removed while the power supply is on turn off...

Page 56: ...t in this section 10 The arc sputters and hisses 10 1 The gas filter element inside the power supply is contaminated Replace element See Air Filter Element Replacement in this section 10 2 There is water in the air line Install or repair air filteration to power supply See Gas Requirements Section 3 11 Cut quality is not good 11 1 Consumables are worn or the torch is being used incorrectly See Ins...

Page 57: ...Sides 1 2 002244 Safety Trigger 1 3 128377 Replacement Start Switch switch and wire splices 1 4 027254 Trigger Spring 1 5 004764 Retaining Ring Gutcha 1 6 075339 Screws P S 4 X 1 2 PH RND S B 5 7 120570 Torch Main Body with Safety Switch 1 8 044016 O Ring BUNA 90 Duro 614X 070 1 9 129475 Replacement Torch Lead 15 ft 4 5 m 1 9 129476 Replacement Torch Lead 25 ft 7 5 m 1 9 129477 Replacement Torch L...

Page 58: ...MAINTENANCE AND PARTS 10 99 powermax600 Operator Manual 5 15 PAC123T 01 Included with replacement assembly PAC123T Hand Torch and Lead Assembly No Quick Disconnect ...

Page 59: ...ides 1 2 002244 Safety Trigger 1 3 128377 Replacement Start Switch switch and wire splices 1 4 027254 Trigger Spring 1 5 004764 Retaining Ring Gutcha 1 6 075339 Screws P S 4 X 1 2 PH RND S B 5 7 120570 Torch Main Body with Safety Switch 1 8 044016 O Ring BUNA 90 Duro 614X 070 1 9 129599 Replacement Torch Lead 15 ft 4 5 m 1 9 129600 Replacement Torch Lead 25 ft 7 5 m 1 9 129601 Replacement Torch Le...

Page 60: ...MAINTENANCE AND PARTS 10 99 powermax600 Operator Manual 5 17 PAC123T 02 Included with replacement lead assembly PAC123T Hand Torch and Lead Assembly With Quick Disconnect ...

Page 61: ...y with 50 ft 15 m Lead No Quick Disconnect 1 120613 Sleeve Machine Torch 1 2 020620 Sleeve Torch Position 1 3 128374 Replacement Torch Lead 15 ft 4 5 m 1 3 128375 Replacement Torch Lead 25 ft 7 5 m 1 3 128376 Replacement Torch Lead 50 ft 15 m 1 4 027599 Snap Ring 1 5 120583 Torch Main Body with Safety Switch 1 6 044016 O Ring BUNA 90 Duro 0 614 X 0 070 inch 1 Top assembly includes the following co...

Page 62: ... 5 19 P A C 1 2 3 M 0 3 On Off Pendant not part of machine torch assembly See Powermax600 Field Upgrade Kits and Optional Parts on page 5 23 for part numbers PAC123M Machine Torch and Lead Assembly No Quick Disconnect Included with replacement lead assembly ...

Page 63: ...Quick Disconnect 1 120613 Sleeve Machine Torch 1 2 020620 Sleeve Torch Position 1 3 128572 Replacement Torch Lead w Quick Disconnect 15 ft 4 5 m 1 3 128573 Replacement Torch Lead w Quick Disconnect 25 ft 7 5 m 1 3 128574 Replacement Torch Lead w Quick Disconnect 50 ft 15 m 1 4 027599 Snap Ring 1 5 120583 Torch Main Body with Safety Switch 1 6 044016 O Ring BUNA 90 Duro 0 614 X 0 070 inch 1 Top ass...

Page 64: ... 5 21 M 04 P A C 123 On Off Pendant not part of machine torch assembly See Powermax600 Field Upgrade Kits and Optional Parts on page 5 23 for part numbers PAC123M Machine Torch and Lead Assembly With Quick Disconnect Included with replacement lead assembly ...

Page 65: ...ermax600 Operator Manual Part Item Number Description Qty 1 011086 Air filter element 1 2 011087 O ring 1 Power Supply Work Cable Part Item Number Description Qty 1 123375 Work Cable with clamp 15 ft 4 6 m 1 Power Supply Filter Regulator ...

Page 66: ...w 128061 On Off Pendant with Lead 50 ft 15 m 128062 On Off Pendant with Lead 75 ft 23 m 128379 Work Cable Kit 50 ft 15 m 128378 Wheel Kit 027112 Circle Cutting Guide 027113 Stabilizer Circle Cutting Guide 027114 Magnetic Pivot Radius Guide 024548 Leather Cable Covers 25 ft 7 5 m Note Contact your distributor or call the nearest Hypertherm office for hand and machine torch system configurations 110...

Page 67: ...MAINTENANCE AND PARTS 10 99 5 24 powermax600 Operator Manual ...

Reviews: