Hypertherm Powermax45 228262 Field Service Bulletin Download Page 2

Hypertherm, Inc.

Etna Road, P.O. Box 5010
Hanover, NH 03755 USA
603-643-3441 Tel (Main Office)
603-643-5352 Fax (All Departments)
[email protected] (Main Office Email)

800-643-9878 Tel (Technical Service)

[email protected] (Technical Service Email)

800-737-2978 Tel (Customer Service)

[email protected] (Customer Service Email)

866-643-7711 Tel (Return Materials Authorization)
877-371-2876 Fax (Return Materials Authorization)

[email protected] (RMA email)

Hypertherm Plasmatechnik GmbH

Technologiepark Hanau
Rodenbacher Chaussee 6 
D-63457 Hanau-Wolfgang, Deutschland
49 6181 58 2100 Tel
49 6181 58 2134 Fax

49 6181 58 2123 (Technical Service)

Hypertherm (S) Pte Ltd.

82 Genting Lane
Media Centre
Annexe Block #A01-01
Singapore 349567, Republic of Singapore
65 6841 2489 Tel
65 6841 2490 Fax 

65 6841 2489 (Technical Service)

Hypertherm (Shanghai) Trading Co., Ltd.

Unit 301, South Building  
495 ShangZhong Road
Shanghai, 200231
PR China
86-21-60740003 Tel
86-21-60740393 Fax

Hypertherm Europe B.V.

Vaartveld 9
4704 SE 
Roosendaal, Nederland
31 165 596907 Tel
31 165 596901 Fax
31 165 596908 Tel (Marketing)

31 165 596900 Tel (Technical Service)
00 800 4973 7843 Tel (Technical Service)

Hypertherm Japan Ltd.

Level 9, Edobori Center Building
2-1-1 Edobori, Nishi-ku
Osaka 550-0002 Japan
81 6 6225 1183 Tel
81 6 6225 1184 Fax

Hypertherm Brasil Ltda.

Rua Bras Cubas, 231 – Jardim Maia
Guarulhos, SP - Brasil
CEP 07115-030
55 11 2409 2636 Tel
55 11 2408 0462 Fax

Hypertherm México, S.A. de C.V.

Avenida Toluca No. 444, Anexo 1,
Colonia Olivar de los Padres
Delegación Álvaro Obregón
México, D.F. C.P. 01780
52 55 5681 8109 Tel
52 55 5683 2127 Fax

Hypertherm Korea Branch

#3904 Centum Leaders Mark B/D,
1514 Woo-dong, Haeundae-gu, Busan
Korea, 612-889
82 51 747 0358 Tel
82 51 701 0358 Fax

© 2013 Hypertherm, Inc. All rights reserved.
Tous droits réservés.

Powermax and Hypertherm are trademarks of Hypertherm, Inc. and may be registered in the United States and/or other countries. All other trademarks 
are the property of their respective holders.

Powermax et Hypertherm sont des marques d’Hypertherm, Inc. qui peuvent être déposées aux États-Unis et/ou dans d’autres pays. Toutes les autres 
marques commerciales sont la propriété de leurs détenteurs respectifs.

Summary of Contents for Powermax45 228262

Page 1: ...Service Bulletin Bulletin de service sur le terrain 805860 Revision 3 April 2013 Révision 3 Avril 2013 Powermax45 Control Board Replacement Kit Kit de remplacement du circuit imprimé de commande du Powermax45 ...

Page 2: ...ld 9 4704 SE Roosendaal Nederland 31 165 596907 Tel 31 165 596901 Fax 31 165 596908 Tel Marketing 31 165 596900 Tel Technical Service 00 800 4973 7843 Tel Technical Service Hypertherm Japan Ltd Level 9 Edobori Center Building 2 1 1 Edobori Nishi ku Osaka 550 0002 Japan 81 6 6225 1183 Tel 81 6 6225 1184 Fax Hypertherm Brasil Ltda Rua Bras Cubas 231 Jardim Maia Guarulhos SP Brasil CEP 07115 030 55 1...

Page 3: ... electrical power before performing any maintenance See the Safety and Compliance Manual for more safety precautions Part number Description Quantity 075418 Plastite screw 4 20 x 1 4 PH PAN 3 104376 Boot Powermax45 toggle switch 1 108616 Knob 0 830 diameter 3 16 inch D 1 141002 PCB 45A control board for 200 240V CSA 230V CE and 400V CE units 1 Part number Description Quantity 075418 Plastite screw...

Page 4: ...n cable from the power board at J7 200 240 V CSA and 230 V CE or J8 400 V CE and 480 V CSA 6 Test the new control board before installing it by attaching its ribbon cable to the power board Reconnect the power turn the system on and verify that the start LED on the control board is the only LED illuminated Also the fault LEDs on the front panel should be extinguished 7 Disconnect the electrical po...

Page 5: ...acement Kit 12 Being careful not to pinch any of the wires replace the Mylar barrier and slide the cover back onto the power supply Position the handle over the holes in the top of the cover then use the 2 screws to secure the cover 13 Reconnect the electrical power and the gas supply ...

Page 6: ...4 Powermax45 Field Service Bulletin 805860 Revision 3 Powermax45 Control Board Replacement Kit ...

Page 7: ...ectrique Se reporter au Manuel de sécurité et de conformité pour des mesures de sécurité supplémentaires Numéro de référence Description Quantité 075418 Vis Plastite tête cylindrique 4 20 x 1 4 PH 3 104376 Gaine interrupteur à levier Powermax45 1 108616 Bouton diamètre 0 830 3 16 po D 1 141002 Carte à circuits imprimés circuit imprimé de commande 45 A pour unités 200 240 V CSA 230 V CE et 400 V CE...

Page 8: ...ment pour le retirer du socle 5 Détacher le câble plat du circuit imprimé d alimentation au niveau de J7 200 240 V CSA et 230 V CE ou de J8 400 V CE et 480 V CSA 6 Tester le nouveau circuit imprimé de commande avant de l installer en attachant le câble plat au circuit imprimé d alimentation Rebrancher l alimentation mettre le système sous tension et vérifier que la DEL de démarrage du circuit impr...

Page 9: ...lat de l ouverture du bouton s aligne avec le côté plat de la tige 11 Repositionner le panneau avant 12 En prenant garde de ne pas pincer les fils replacer la barrière Mylar et faire coulisser le couvercle sur la source de courant pour le remettre en place Positionner la poignée sur les orifices de la partie supérieure du couvercle puis utiliser les deux vis pour fixer le couvercle 13 Reconnecter ...

Page 10: ...a 4 Powermax45 Bulletin de service sur le terrain 805860 Révision 3 Kit de remplacement du circuit imprimé de commande du Powermax45 ...

Reviews: