6-5
3
U22
U23
(VISIBLE FOR 10 SEC. AFTER EVENT)
TORCH STUCK OPEN
40 POSITION RIBBON CABLE
(VISIBLE FOR 10 SEC. AFTER EVENT)
129683
WIRE GROUP
123607
123603
003206
NA
041667
POWER SWITCH (S1)
MACHINE INTERFACE CABLE
POWER BD (PCB2)
FILTER (PCB1)
CONTROL BD (PCB3)
123603
041660
003206
041667
041663
041707
80 AMP UNIT
1.41 X Vac
129652
200-600vac
750
INPUT VOLTAGE
Vbus (Vac>541vac)
CORD
Vbus (Vac<540vac)
750
NA
129653
70
50
STATUS
GAS
45
60
55
65
75
80
85
TSO
SP
SPARE
0.10uF
009994
33
J4
108171
39
40
37
38
35
36
34
008924
0.01uF
100VDC
009990
TP1
IFB
ITF
VACR
C41
50V
R50
100
009073
C52
32
30
31
28
29
26
27
22
25
24
23
21
19
20
009994
VBUS
+5
C1
0.10uF
50V
+5
/IOC
009115
10
R4
R3
10
009115
TEMP
PCB4
SENSOR BD
HEATSINK
SENSOR
SA
PRESSURE
1
3 2
B
Y
J5
R
TEMP
SENSOR IN
XFMR
T2
J21
2
B
R
1
3
B
2
X
SA
FAN
Y
1
J2
1
R
2
B
J1
GAS SOLENOID
SA
B
3 2
R
1
J20
X
+24
10
R117
10
009115
009115
R116
+5
+5
DIAGNOSTIC LED'S
START SIGNAL VALID
INVERTER INTERLOCK
(BLINKING @ 1 SEC. RATE)
SELF DIAGNOSTICS FAILURE
INSTALL JUMPER 108056 CE UNITS ONLY
PCB3
CPA
NORMAL
GOUGE
CURRENT
DOWN
MID
UP
CONTROL BD
P1
XFR
SDF
IF
TRANSFER
START
(PE)
BRN
GRN/YEL
BLK
BLU
CE UNIT
CORD
S1
J1
AUX
FILTER
PCB1 J2
(PE)
RED
GRN
AUX
DOMESTIC UNIT
BLK
WHT
S1
CORD
3
10
7
11
18
17
15
16
13
14
12
10
8
9
6
7
4
5
D8
C18
50V
0.10uF
009994
5.1V
1N5231B
109109
OUTB
R22
R8
009883
1/2W
2.21K
009414
499
009036
OUTA
8
+V
7B
-V
7C
9
R7
2.0K
3
1
109223
55V
IRLZ44N
0.022ohm
C13
0.10uF
50V
009994
2
/MM
+24
Q1
2
3
1
J3
B
Y
1
+24
PE
2
MTG-4
1
3
2
4
5
6
3B 3C
4B 4C
6B 6C
5C
5B
13
12
11
1C
1B
2B 2C
16
14
15
042188
ULN2003A
U1
/PREFLOW
/SSR
/PA
t
60V 0.20A
RT7
109024
BRIDGE
~
-
~
~
D24
INPUT
+
GND
CONTROL
-6
COMT
18REG
18T
COMINV
18INV
FLYBACK
SUPPLY
POWER
SYSTEM
T1
18PA
COMPA
+5
+10
+24
PE
CKT
PFC
CONTROL
POWER BD PCB2
SOFT START
K1
VacR
I
Vbus
1
3
2
J8
PFC
IGBT
Q7
C94
+
2
1
J6
3
2
Vbus
OR J10
J9
PFC CHOKE
C98
+
J7
1
POWER
TRANSFORMER
20 OHM
YEL
J13
YEL
P2
50W
BRN
BRN
INVERTER
IGBT Q6
T2
ITF
SENSOR
J19
/MM
+24
4
3
COMT
18T
2
1
12
10
11
INTERFACE
GND
CHASSIS
BLK
GRN/YEL
YEL
12
13
14
MACHINE
START
WHT
RED
3
4
CAP
1
COMT
8
9
6
7
4
5
2
3
J18
J17
CKT
J14
WHT
RED
NOZZLE
ELECTRODE
WORK LEAD
TRANSFER
IFB
CURRENT
SENSOR
FEEDBACK
J12
IGBT
PILOT ARC
NC
INDUCTOR
OUTPUT
B
R
OUTPUT
DIODES
J11
7.5 ohm
100W
NA
1.41 X Vac
750
750
NA
60 AMP UNIT
087000(DOMESTIC)
087007(CE)
083169(DOMESTIC)
083170(CE)
1/3PH
230-400vac
3PH
200-600vac
1/3 PH
230-400vac
3PH
TEMP SENSOR BD (PCB4)
041723
041723
TIMING DIAGRAM
013341
013341
129652
129726
129732
123603
123603
005257
005257
041746
041746
041709
041710
041713
041713
013341
013341
041773
LOCKOUT
VIO
ORG
BLUE
129739
NOTES:
1. PIN 6 IS KEYING FEATURE ON 60A
2. PIN 9 IS LOCKOUT FEATURE
6
5
+
-
+24
24VDC @100MA MAX
TOLERANCES ARE:
UNLESS OTHERWISE SPECIFIED:
2 PL DECIMAL ±.01
FRACTIONS ±1/64
ANGULAR ±.5∞
DIMENSIONS ARE IN INCHES.
3 PL DECIMAL ±.005
PART MUST BE FREE OF BURRS AND SHARP
EDGES. BREAK SHARP EDGES IF NECESSARY
WITH CHAMFER OR RADIUS .015 MAX.
PURPOSES WITHOUT PERMISSION
FOR MANUFACTURING OR FABRICATION
FROM HYPERTHERM, INC.
THIS DRAWING AND ALL INFORMATION
PROPRIETARY AND MAY NOT BE USED
CONTAINED THEREON IS CONSIDERED
MATERIAL
1=1
1 OF 1
SCALE
Box-5010 Hanover, NH 03755-5010 603/643-3441
SHEET
8
7
6
3
5
4
2
1
A
B
C
D
8
7
6
3
5
4
2
1
A
B
C
D
C