286
Powermax125
Service Manual 808070
10 – Torch Component Replacement
Install the mounting sleeve
1.
Slide the mounting sleeve onto the torch body.
2.
Install the screws on the face of the mounting sleeve.
3.
Reinstall the consumables.
4.
Screw the coupler onto the mounting sleeve.
5.
Screw the positioning sleeve (full-length only) or adapter (mini only) onto the coupler.
6.
Screw the strain relief onto the positioning sleeve (full-length only) or adapter (mini only).
7.
Screw the strain relief nut onto the strain relief.
8.
Reconnect the torch and gas supply, and turn ON (
I
) the power.