244
Powermax125
Service Manual 808070
9 – Power Supply Component Replacement
Replacing the transformer
Remove the transformer
1.
Complete the following procedures:
a.
Disconnect the power and gas supply
b.
c.
d.
2.
From the power board side of the power supply, remove the 2 screws securing the long transformer wires to the
output diode bridge.
3.
Remove the screw and bolt securing the short transformer wires to the power board.
The power board in
is a CSA model. The connections for the transformer wires
are the same for all models.
Figure 99
Kit number
Description
Kit: Powermax125 transformer 480 V CSA
Kit: Powermax125 transformer 600 V CSA
Kit: Powermax125 transformer 400 V CE/380 V CCC
J22
J21
J20
J19
J27
WORK
LEAD
J26
J25
+
_
+
_
RED
J18
ORG
J17
RED
J32
J11
B
R
J28
C152
C151
TP7
TP9
TP8
W
R
B
Long transformer wires
Short transformer wires
Power board