5 – Preventive maintenance
Preventi
ve maintenance
Low-pressure water system
Check the low-pressure water pressure gauges
The prefilter water-pressure gauge shows the water pressure before the water goes through the filters. The
postfilter water-pressure gauge shows the water pressure after the water goes through the filters.
The usual operating range is 2.76 bar to 7.58 bar or 275.79 kPa to 758.42 kPa (40 psi to 110 psi).
Do this task when the pump is running.
Subtract the value shown on the postfilter water pressure from the value shown on the prefilter water pressure.
Replace the filters if the difference between the values on the pre- and the postfilter water-pressure gauges is
higher than 0.69 bar or 68.95 kPa (10 psi).
Service
Interval
Check the low-pressure water pressure gauges
Before every work shift
Replace the water filters (page 91)
After every 1,000 hours of operation or if the difference
between the values on the pre- and the postfilter
water-pressure gauges is higher than 0.69 bar
or 68.95 kPa (10 psi)
1
2
1
Prefilter water-pressure gauge
2
Postfilter water-pressure gauge
Summary of Contents for HyPrecision 50S
Page 1: ...HyPrecision 50S 60S 75S Waterjet Pump Operator Manual 808690 Revision 2 English ...
Page 10: ...10 HyPrecision 50S 60S 75S Operator Manual 808690 Pump information ...
Page 12: ...SC 12 Safety and compliance Warranty Warranty ...
Page 16: ...SC 16 Safety and compliance Product stewardship Product stewardship ...
Page 24: ...SC 24 Safety and compliance Symbols and marks Symbols and marks ...
Page 42: ...42 HyPrecision 50S 60S 75S Operator Manual 808690 3 Options Options ...
Page 68: ...68 HyPrecision 50S 60S 75S Operator Manual 808690 4 Operation Operation ...
Page 172: ...172 HyPrecision 50S 60S 75S Operator Manual 808690 7 Troubleshooting Troubleshooting ...