5 – Preventive maintenance
Preventive main
tenance
High-pressure water system: Bleed-down valve
Examine the bleed-down valve for leaks or damage
Weep hole 1 will leak hydraulic fluid. The others will leak water.
Do this task when the pump is running.
1.
Remove the pump end panel.
2.
Monitor for leaks. Identify the source of a leak and correct the problem. Refer to
CAUTION
Failure to correct the cause of a leak can cause damage to the water fittings.
Service
Interval
Examine the bleed-down valve for leaks or damage
Every work shift
WARNING
Do not attempt to repair a leak with pressure in the system.
WARNING
Use a piece of cardboard or other solid material to check for leaks when the pump is on. Do not
use hands, cloth, paper, or towels.
1
3
2
4
5
1
O-ring
2
High-pressure seal
3
High-pressure water connection
4
Poppet seat
5
Output connection
Summary of Contents for HyPrecision 50S
Page 1: ...HyPrecision 50S 60S 75S Waterjet Pump Operator Manual 808690 Revision 2 English ...
Page 10: ...10 HyPrecision 50S 60S 75S Operator Manual 808690 Pump information ...
Page 12: ...SC 12 Safety and compliance Warranty Warranty ...
Page 16: ...SC 16 Safety and compliance Product stewardship Product stewardship ...
Page 24: ...SC 24 Safety and compliance Symbols and marks Symbols and marks ...
Page 42: ...42 HyPrecision 50S 60S 75S Operator Manual 808690 3 Options Options ...
Page 68: ...68 HyPrecision 50S 60S 75S Operator Manual 808690 4 Operation Operation ...
Page 172: ...172 HyPrecision 50S 60S 75S Operator Manual 808690 7 Troubleshooting Troubleshooting ...