Maintenance
5-58
HPR400XD Auto Gas –
806160
chopper tests
Automatic chopper tests during power-up
When the power is turned ON, the contactor will close and each chopper will automatically test in sequence (1, 3, 2,
and 4). If the status changes to 3, all choppers passed the test. After the tests are complete the unit will advance to the
purge cycle unless an error is detected on one of the choppers.
As each chopper is turned on, the current flows into the surge circuit and is measured for high and low limits. If the
chopper passes the test, the next chopper is tested.
If chopper 1 passes the test and one of the other choppers fails, you can assume that the main contactor, the input
power, and the surge circuit are OK.
Error codes:
Chopper 1 – low-current error code 105
Chopper 2 – low-current error code 106
Chopper 1 – high-current error code 103
Chopper 2 – high-current error code 104
Chopper 3 – low-current error code 075
Chopper 4 – low-current error code 076
Chopper 3 – high-current error code 107
Chopper 4 – high-current error code 095
chopper 1 failure
1. Turn OFF all power to the system.
2. Remove the cover over the main contactor (CON1) and inspect
the contacts for arcing or damage.
• If the contacts are damaged, replace the contactor.
• If the contacts are OK, replace the cover, turn ON the power,
and continue to step 3.
OK
Excessive wear
CON1
wARNINg
SHock HAzARD
Use extreme care when working near the chopper modules. Each large electrolytic capacitor (blue-
cased cylinder) stores large amounts of energy in the form of electric voltage. Even if the power is
off, dangerous voltages exist at the capacitor terminals, on the chopper, and the diode heatsinks.
Never discharge any capacitor with a screwdriver or other implement… explosion, property
damage and/or personal injury will result.
Summary of Contents for HyPerformance Plasma HPR400
Page 1: ...HyPerformance Plasma HPR400XD Auto gas Instruction manual 806160 Revision 4 ...
Page 26: ...Specifications 2 2 HPR400XD Auto Gas 806160 ...
Page 48: ...Installation 3 10 HPR400XD Auto Gas 806160 ...
Page 53: ...Installation HPR400XD Auto Gas 806160 3 15 Horizontal RHF mounting Vertical RHF mounting ...
Page 57: ...Installation HPR400XD Auto Gas 806160 3 19 This page is blank intentionally ...
Page 65: ...Installation HPR400XD Auto Gas 806160 3 27 7 8 8 7 ...
Page 100: ...Installation 3 62 HPR400XD Auto Gas 806160 ...
Page 107: ...Operation HPR400XD Auto Gas 806160 4 7 Diagnostic screen ...
Page 108: ...Operation 4 8 HPR400XD Auto Gas 806160 Test screen ...
Page 109: ...Operation HPR400XD Auto Gas 806160 4 9 Cut chart screen ...
Page 197: ...Operation HPR400XD Auto Gas 806160 4 97 ...
Page 287: ...7 4 HPR400XD Auto Gas 806160 Discrete output functionality ...
Page 347: ...Appendix B CNC Interface Protocol b 28 HPR400XD Auto Gas 806160 ...
Page 355: ...4 HPR400XD Auto Gas 806160 ...