Maintenance
5-24
HPR130XD Auto Gas –
806330
Error code troubleshooting – error codes 153 to 156, 354 to 356
Error code
number
Name
Description
corrective action
153
PS EEPROM
error
EEPROM memory on
power supply control
board not working.
Replace the control board.
154
Primary
354
Secondary
Chopper 3
overcurrent
HPR400XD
only
Chopper 3 current
feedback has exceeded
160 amperes.
1. Verify that the wiring between CS3 and PCB3 is correct
and not damaged.
2. Measure voltage across current sensor.
a) Red to black = +15 VDC, Green to black = -15 VDC,
white to black = 0 VDC at idle and varies with current
output (4 VDC = 100 A).
b) If possible, take a voltage reading on current sensor
while trying to cut. Ratio is 4 VDC = 100 A.
c) If the current sensor voltage is approximately 6.4 VDC
or greater at idle, replace the current sensor.
3. Remove connector JC.1 from the chopper and verify that
LED1 is extinguished.
a) If LED1 is extinguished with the connector removed,
then reconnect JC.1 and try to fire the torch. If the
chopper still goes into overcurrent, replace the chopper.
b) If the chopper does not go into overcurrent, replace
PCB3..
155
Primary
355
Secondary
Chopper 4
overcurrent
HPR400XD
only
Chopper 4 current
feedback has exceeded
160 amperes.
1. Verify that the wiring between CS4 and PCB3 is correct
and not damaged.
2. Measure voltage across current sensor.
a) Red to black = +15 VDC, Green to black = -15 VDC,
white to black = 0 VDC at idle and varies with current
output (4 VDC = 100 A).
b) If possible, take a voltage reading on current sensor
while trying to cut. Ratio is 4 VDC = 100 A.
c) If the current sensor voltage is approximately 6.4 VDC
or greater at idle, replace the current sensor.
3. Remove connector JD.1 from the chopper and verify that
LED1 is extinguished.
a) If LED1 is extinguished with the connector removed,
then reconnect JD.1 and try to fire the torch. If the
chopper still goes into overcurrent, replace the chopper.
b) If the chopper does not go into overcurrent, replace
PCB3.
156
Primary
356
Secondary
Chopper 2
current at
power-up
HPR260XD
HPR400XD
only
Chopper 2 current signal
is active at power-up.
See wiring diagrams in section 7
1. Verify that the voltage at CS2 is correct.
2. Verify that the wiring between CS2 and PCB3 is correct
and not damaged.
3. Swap CS2 with CS3. If the error code changes to 157,
replace the original CS2.
Summary of Contents for HyPerformance HPR130XD
Page 1: ...HyPerformance Plasma HPR130XD Auto gas Instruction manual 806330 Revision 3 ...
Page 16: ...Table of Contents viii HPR130XD Auto Gas 806330 ...
Page 26: ...Specifications 2 2 HPR130XD Auto Gas 806330 ...
Page 38: ...Specifications 2 14 HPR130XD Auto Gas 806330 ...
Page 48: ...Installation 3 10 HPR130XD Auto Gas 806330 ...
Page 59: ...Installation HPR130XD Auto Gas 806330 3 21 1X1 J103 J300 Female Male 5 6 5 6 3X1 3X2 3X3 3X4 ...
Page 94: ...Installation 3 56 HPR130XD Auto Gas 806330 ...
Page 101: ...Operation HPR130XD Auto Gas 806330 Revision 2 4 7 Diagnostics screen ...
Page 102: ...Operation 4 8 HPR130XD Auto Gas 806330 Revision 2 Test screen ...
Page 103: ...Operation HPR130XD Auto Gas 806330 Revision 2 4 9 Cut chart screen ...
Page 152: ...Operation 4 58 HPR130XD Auto Gas 806330 Revision 2 ...
Page 236: ...7 4 HPR130XD Auto Gas 806330 Discrete output functionality ...
Page 294: ...Appendix B CNC Interface Protocol b 28 HPR130XD Auto Gas 806330 Revision 1 ...
Page 302: ...4 HPR130XD Auto Gas 806330 ...