Maintenance
HPR130XD Auto Gas –
806330
5-21
Error code troubleshooting – error codes 116 to 133, 316
Error code
number
Name
Description
corrective action
116
Primary
316
Secondary
Watchdog
interlock
An error occurred with
the CAN communication
system.
1. Verify that cable number 5 (power supply-to-gas console
control cable) is not damaged and is properly connected
to PCB3 and the rear of the gas console.
2. Verify that cable number 6 (power supply-to-gas console
power cable) is not damaged and is properly connected
inside the power supply and to the rear of the gas
console.
3a.
(Manual gas console)
Verify that D1 (+5 VDC) and
D2 (+3.3 VDC) are illuminated on PCB2 inside the gas
console. These LEDs indicate power to PCB2.
3b.
(Auto gas console)
Verify that D17 (+5 VDC) and
D18 (+3.3 VDC) are illuminated on PCB2 inside the gas
console. These LEDs indicate power to PCB2.
4. If power is present at PCB2 and PCB3 and both gas
console cables are good, then PCB2 or PCB3 has failed.
Use the CAN tester to verify which board needs to be
replaced.
5. Verify that the gas console control PCB and power
distribution PCBs are securely mounted to the chassis at
all four corners.
123
MV1 error
Auto gas
only
Motor valve 1 did not
move into position within
60 seconds.
Verify that LED D17 or D18 illuminates on the AC valve
driver PCB in the selection console. If either illuminates,
replace the motor valve. If they do not illuminate, replace
PCB3.
124
MV2 error
Auto gas
only
Motor valve 2 did not
move into position within
60 seconds.
Verify that LED D19 or D20 illuminates on the AC valve
driver PCB in the selection console. If either illuminates,
replace the motor valve. If they do not illuminate, replace
PCB3.
133
Unknown gas
console type
The power supply control
board does not recognize
the gas console that
is installed or has not
received a CAN message.
1. Verify that the part numbers of PCB2 and PCB3 are
correct.
2. Verify that the power supply-to-gas console control cable
is not damaged and is properly connected to PCB3 and
the rear of the gas console.
3. Verify that the power supply-to-gas console power cable
is not damaged and is properly connected inside the
power supply and to the rear of the gas console.
4. Verify that D1 (+5 VDC) and D2 (+3.3 VDC) are
illuminated on PCB2 inside the gas console. These LEDs
indicate power to PCB2.
5. If power is present at PCB2 and PCB3 and both gas
console cables are good, then PCB2 or PCB3 has failed.
Use the CAN tester to verify which board needs to be
replaced.
Summary of Contents for HyPerformance HPR130XD
Page 1: ...HyPerformance Plasma HPR130XD Auto gas Instruction manual 806330 Revision 3 ...
Page 16: ...Table of Contents viii HPR130XD Auto Gas 806330 ...
Page 26: ...Specifications 2 2 HPR130XD Auto Gas 806330 ...
Page 38: ...Specifications 2 14 HPR130XD Auto Gas 806330 ...
Page 48: ...Installation 3 10 HPR130XD Auto Gas 806330 ...
Page 59: ...Installation HPR130XD Auto Gas 806330 3 21 1X1 J103 J300 Female Male 5 6 5 6 3X1 3X2 3X3 3X4 ...
Page 94: ...Installation 3 56 HPR130XD Auto Gas 806330 ...
Page 101: ...Operation HPR130XD Auto Gas 806330 Revision 2 4 7 Diagnostics screen ...
Page 102: ...Operation 4 8 HPR130XD Auto Gas 806330 Revision 2 Test screen ...
Page 103: ...Operation HPR130XD Auto Gas 806330 Revision 2 4 9 Cut chart screen ...
Page 152: ...Operation 4 58 HPR130XD Auto Gas 806330 Revision 2 ...
Page 236: ...7 4 HPR130XD Auto Gas 806330 Discrete output functionality ...
Page 294: ...Appendix B CNC Interface Protocol b 28 HPR130XD Auto Gas 806330 Revision 1 ...
Page 302: ...4 HPR130XD Auto Gas 806330 ...