62
Duramax Hyamp Long Handheld Torches
Service Manual 808290
4 – Component Replacement
Replace the torch body
The torch body assembly is made up of the torch head and the long gas tube. The torch body kits listed above also
include a pilot arc wire and a cap-sensor switch.
Remove the torch body
1.
Turn OFF (
O
) the power, disconnect the gas supply, and disconnect the torch.
2.
Remove all components from the upper and lower parts of the torch, including the consumables. See
3.
Gently pull the cap-sensor switch connector and the pilot terminal screw (encased in heatshrink) out of the trigger
end of the extension tube.
4.
Disconnect the cap-sensor switch at the trigger end of the extension tube by pressing the tab on the connector and
pulling the connector apart.
Figure 18
Kit
Description
Cap-sensor switch
Tab