9.6.1 Solenoid valve (removal, rein-
stallation)
Removal
»
Shut off water supply and disconnect
tap water hose cap screw connection.
»
Remove connecting hose (20*) from
cylinder base.
»
Detach electrical cable connector
from solenoid valve (25*).
»
Unscrew solenoid valve mounting
screws.
»
Remove solenoid valve from hous-
ing bore.
Reinstallation
»
Reinsert fine filter into solenoid valve.
»
Reinsert solenoid valve with seal in
unit housing bore.
»
Bolt-down solenoid valve.
»
Re-establish tap water connection.
»
Reconnect electrical cable to sole-
noid valve.
»
Reattach connecting hose (20) to
cylinder base using clamp.
»
Follow the handling instructions in
the section
Leakage test.
*) the numbers refer to the exploded view in the same
named chapter
9.7 Leak test
Risk of electrical shock!
Hazardous electrical voltage!
Follow safety instruction for work on live com-
ponents.
Leakages may invoke leak currents.
The leak test described below must be done
after all maintenance work that affects the
water circuit inside the unit. If work has been
done at several points, the final leak test is
enough, although this work step is listed for
all parts of the work.
The leak test must be done with the unit
open, paying particular attention to the warn-
ing above.
»
Open the water supply.
»
Switch on the unit and check the
inside for leaks (hose connections,
O-rings, seals) after 15-30 minutes
of operation.
»
In case of leakage turn off power
supply and secure against being
switched on again.
»
Find leakage and eliminate.
»
Check again.
»
Follow the instructions in the sec-
tion
funktional check
.
9.8 Functional check
»
Run the system with maximum out-
put for a couple of minutes
»
Check hose connections and seals
for leakage.