START-UP OF THE SERVICE MEASURING KIT
HySense
®
CX 197
17
ENG
4.3 Connecting the sensors
Figure 7 shows the CAN data line together with the power pack and the data
line. Proceed as follows:
•
Connect the sensors with the included CAN cable (point
A
•
Connect the plug of the CAN cable (point
B
, Figure 7) to the CAN system
or measurement instrument (MS5060Plus, MS5070 or MS4070)
•
If the sensors are supplied autonomously with current, the plug on the CAN
data line (point
B
, Figure 7) is connected to the socket of the power pack
(point
C
, Figure 7). Then the plug on the power pack (point
D
, Figure 7) is
used as the data line of the CAN bus.
Warning
Risk of burns
When ventilating, note that skin contact with hot oil can cause burns. Adjust the oil
pressure so that only a little oil escapes.
A
B
C
D
Figure 7: CAN data line with network connection