Programming Levels 

There are 3 levels to the valve program.  Master options and Factory options are typically adjusted at the fac-

tory.  These options link the PCB function with the type of control valve and should not be tampered with.  

Advanced options are used to configure the unit when the valve is assembled to the tank so that it can func-
tion as the proper size and intended system operation.  Settings are the final options chosen when the unit is 

installed to a specific location. 

Button Configuration 

Key Pad Configuration 

MENU This 

func on is to enter the basic set up informa on required at the  me of installa on. 

SET This 

func on is to accept the values if changed and advance to the next page in the menu. 

+ / - 

These bu ons are used to increase or decrease the value of the se ngs while in the  pro-
gramming mode. 

Main Display Options 

The main display page shows the Flow Rate, Date, Time Of Day, Remaining Volume, and Total Volume.  The 

display will alternate between the main page and the dealer information page. 

PROGRAM LEVEL 

USER ACCESS 

MAIN MENU (II) 

These se ngs are programmed when the unit is installed.  The se ngs should only be adjusted by a quali-

fi

ed person. 

ADVANCED MENU (II) 

These se ngs are programmed by the factory and should be adjusted when the valve is assembled into a 
unit or system.  It contains important se ngs so the valve will operate properly for the type of system it is 
intended for.  The se ngs should only be changed by quali

fi

ed person. 

HISTORY MENU (IV) 

This menu contains key diagnos cs for trouble shoo ng the system.  

USER SETTINGS(I) 

These se ngs are programmed when the unit is installed.  The se ngs should only be adjusted by a quali-

fi

ed person. 

FACTORY MENU (V) 

These se ngs are programmed by the factory.  The se ngs are important for the opera on of the valve 

Flow Rate: 24.5 GPM 

18-Apr-2015   10:35AM 

Remain: 1,280 GAL 

Capacity: 1,500 GAL 

-

 

MENU 

SET 

Summary of Contents for 89 HIMTLC Series

Page 1: ...alla on by applying provided with install kit NSF cer fied lubri cant to all seals 3 This system is not intended for trea ng water that is microbiologically unsafe or of unknown quality without adequa...

Page 2: ...treating water that is microbiologi cally unsafe or of unknown quality without adequate disinfection before or after the system For your safety the information in this manual must be followed to mini...

Page 3: ...ces Use only lead free solder and flux for all sweat solder connections as required by state and federal codes Maximum allowable inlet water pressure is 125 psi If daytime pressure is over 80 psi nigh...

Page 4: ...d bypass valve or 3 shut off valves Bypass valves let you turn off water to the softener for repairs if needed but still have water in the house pipes 5 8 OD drain line is needed for the valve drain A...

Page 5: ...ot covered by the war ranty Put the softener in a place water damage is least likely to occur if a leak develops The manufacturer will not repair or pay for water damage A 120 volt electric outlet to...

Page 6: ...of the parallel tank adaptor used in our dual tank products i e BIF BAF HTO HEDP etc has been redeveloped This new shorter version will also change the New flow directions OUT IN New Style Parallel Ta...

Page 7: ...ube and flows upwards in the tank 2 regenerating the media bed It then travels to tank 1 through the center of the distribution tube and flows upwards in tank 1 and then out to the drain Settle Rinse...

Page 8: ...his could cause damage to the valve 5 Connect the drain hose 10 ft included to the valve and secure it with a hose clamp also included Run the drain hose to the nearest laundry tub or drain pipe This...

Page 9: ...9 Installation...

Page 10: ...the O ring is coated with grease 2 Connec on method of inlet and outlet connector same as the above make sure to connect according to the direc on of arrow seeing from the top view 3 It is also recom...

Page 11: ...n close the bypass valve slowly open the inlet valve the raw water filling the tank and empty the air of the system open the valve more un l the backwash water is clean 5 Press any key to advance the...

Page 12: ...ions The main display page shows the Flow Rate Date Time Of Day Remaining Volume and Total Volume The display will alternate between the main page and the dealer information page PROGRAM LEVEL USER AC...

Page 13: ...E Time of day is for normal operation of system and the scheduling of the regeneration time The date is used in a diagnostic function to track the last time the sys tem regenerated HARDNESS This value...

Page 14: ...OW valve backwash brine slow rinse fast rinse service refill The regenera on steps of UP FLOW valve brine slow rinse backwash fast rinse service refill Set the Down Flow valve as an example when the v...

Page 15: ...Rinse the screen will display Press any key will stop fast rinse and the valve will advance to the next regenera on process Refill the screen will display Press any key will stop service refill and t...

Page 16: ...6 Screws 8 7 85 drive gear 1 8 Connect screw 1 9 85HE main gear 1 10 Brine gear screw 1 11 Locating wheel assembly three options Down flow wheel Up flow wheel Filter wheel 1 12 85HE brine gear 1 13 Mi...

Page 17: ...n assembly No Part description Qty No Part description Qty 1 Big O ring of Adaptor coupling 2 6 89 secure clip 2 2 Adaptor coupling of 89 control valve 2 7 89 valve connector 1 3 Small O ring of adapt...

Page 18: ...lve body 1 2 95 secure clip 1 3 DLFC assembly optional 1S 2S 3S 4S 1 3 4 5 6 1 4 Drain elbow O ring 1 5 Drain elbow 1 2 3 4 1 6 Brine valve injector stem assembly 1 7 Spacer and seal assembly 1 8 Thre...

Page 19: ...rine line adaptor assem bly optional BLFC 0 7gpm BLFC 0 95gpm 1 16 Injector assembly optional grey purple red white blue yellow 1 17 Injector cover O ring 1 18 Injector cover 1 19 Injector cover screw...

Page 20: ...a to form or grow However during shipping storage installing and operating bac teria could get into the softener For this reason sanitizing as follows is suggested when in stalling Sani System Liquid...

Page 21: ...21 Brine Tank Res Up Feeder Assembly 80030022 64 OZ PRO RESCARE...

Page 22: ...22 Blank Page...

Page 23: ...23 Blank Page...

Page 24: ...ions described in the gen eral conditions of this warranty General Conditions Damage to any part of this water conditioner as a result of misuse misapplication neglect alteration accident installation...

Reviews: