![Hydrotech 89 BAF Owner'S Manual Download Page 29](http://html1.mh-extra.com/html/hydrotech/89-baf/89-baf_owners-manual_2192479029.webp)
28
29
A
B
C
D
E
E
F
F
G
K
L
H
I
J
Greased on
parallel tank
connector O ring
Greased on Tank
Adaptor O ring
Greased on the 3/4 straight and 90
degree connector O ring
Greased on Tank
Connector O ring
CIRCUIT BOARD REPLACEMENT
Wire connections to Circuit Board
Circuit Board Screws
A.
Parallel tank connector w/ O ring
B.
Top pipe connector
C.
Bottom pipe connector
D.
Tank adaptor w/ O ring
E.
Red Clips (4pcs)
F.
3/4 “ x 3 Straight , w O ring
G.
3/4” x1 90 degree, w/ Oring
H.
Clamp ring
I.
Valve base
J.
Tank Base
K.
O ring
L.
Retainer ring
Disassemble the adaptor
AFTER SERVICING
SERVICING OF PARALLEL ADAPTOR
Tank and Valve Connection Parts
1.
Reconnect drain line
2.
Return bypass or inlet valve to normal in service position. Water Pressure will automatically build in the filter
3.
Check for leaks at all sealed areas. Check Drain seal with the control in the backwash position
4.
Plug electrical cord into outlet
5.
Set Time of Day and cycle the control valve manually to assure proper function. Make sure control valve is returned to the In Service position
NOTE:
Be sure to shut off any bypass line.
1.
Remove the screws from the back of the valve and pull the front
cover
2.
Remove all connections from the circuit board
3.
Remove the fours screws from the circuit board and pull it out
Ensure all Oring on both tank
connectors are properly dissembled
and apply a good amount of grease.
Summary of Contents for 89 BAF