Hydrotech Water 15010670 Installation And Operation Manual Download Page 3

3  

Proper Installation 

This water filter system must be properly installed and located in accordance with the 

Installation Instructions before it is used. 

 

Install or store where it will not be ex-

posed to temperatures below freezing or 
exposed to any type of weather.  Water 
freezing in the system will break it. Do not 
attempt to treat water over 100°F. 

 

Do not 

install in direct sunlight.  Excessive 

sun or heat may cause distortion or other 
damage to non-metallic parts. 

 

Properly ground to  conform with all gov-
erning codes and ordinances. 

 

Use only 

lead-free solder and flux for all 

sweat-solder connections, as required by 
state and federal codes. 

 

The water filter system requires a mini-

mum water flow of three gallons per mi-
nute at the inlet. 

 

Maximum allowable inlet water pressure is 
125 psi.  If daytime pressure is over 80 

psi, night time pressure may exceed the 
maximum.  Use a pressure reducing valve 
to reduce the flow if necessary. 

 

WARNING: 

Discard all unused parts and 

packaging material after installation. Small 
parts remaining after the installation could 

be a choke hazard. 

Summary of Contents for 15010670

Page 1: ...certified lubri cant to all seals 2 This system is not intended for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system 3 Fi...

Page 2: ...tion 3 Specification 4 Before Starting Installation 6 Sizing Requirements 8 Installation Instructions 9 System Start Up 11 Plumbing System Clean Up 12 Programming Instructions 13 About The System 14 M...

Page 3: ...damage to non metallic parts Properly ground to conform with all gov erning codes and ordinances Use only lead free solder and flux for all sweat solder connections as required by state and federal co...

Page 4: ...these devices will not exceed 15 psig Item Model Media Cu Ft Flow Rate USGPM Mineral Tank Size Pipe Size Inches Ship Weight Lbs Service Peak Back AIO Air Induction Oxidizer Chemical Free Iron Filter...

Page 5: ...is pre oxidized from the air bub ble on the top of the tank and this media removes the iron and manganese from the water This is not rec ommended to remove hydrogen sulfide from the water and require...

Page 6: ...and a pH of 7 0 is neutral The lower the pH value is be low 7 0 the greater the acidity and the high er the pH value is above 7 0 the more alka line Acidic water pH less than 7 0 is corro sive to pipe...

Page 7: ...is not covered by the warranty Put the filter in a place water damage is least likely to occur if a leak develops The manufacturer will not repair or pay for wa ter damage A 120 volt electric outlet...

Page 8: ...resulting in iron bleeding out into the service water In order for your filter to backwash and rinse properly your pump must be capable of providing the backwash flow rates indicated on page 4 Check Y...

Page 9: ...to local plumbing codes Use a minimum pipe or tub ing size for the drain line Use a pipe or tubing for backwash flow rates that exceed 7 gpm or length that exceeds 20ft 6 m NOTE ON COPPER PLUMBING SYS...

Page 10: ...water enters too quickly it will push the media or carbon up into the control valve and get plugged 5 Once the unit has filled sufficiently that water is at least equal to the height of the top of the...

Page 11: ...zed service outlet be consulted prior to performing the procedure The plumbing system and water using appli ances that have been exposed even for a short time to iron fouled water need to be cleaned o...

Page 12: ...approximately 1 2 gallon of household bleach into the top of the heater tank Allow bleach solution to stand in tank for 20 to 30 minutes Flush the tank again until water is clear at the drain Turn en...

Page 13: ...n a non volatile memory and will not be lost during a power failure If power fails while the unit is in regeneration the valve will finish regenera tion from the point it is at once power is restored...

Page 14: ...explains the regeneration steps Regeneration Process Manual Bypass In the case of emergency you can isolate your water filter from the water supply using the bypass valve located at the back of the c...

Page 15: ...n the filter media will require replace ment 3 Periodically check that the drain line is clear and free from any obstructions Check to ensure all media parts are received The first step in replacing t...

Page 16: ...ease installation of the riser tube DO NOT use petroleum based lubricants as they will cause swelling of O ring seals Load the bag s of media into the tank in the following order Chem Free Filters 1...

Page 17: ...by opening a cold soft water faucet 2 Using a screwdriver remove the two screws holding the injector cover to the control valve body 3 Carefully remove the assembly and disassemble as shown above The...

Page 18: ...18 Replacing Drain Line Flow Control DLFC 1 Remove the red clip that secures the drain line elbow 2 Remove the BLFC washer from the elbow fitting 3 Reassemble using the reverse procedure...

Page 19: ...BOW A 2 60010019 1 NPT STRAIGHT A 2 60010023 3 4 NPT STRAIGHT A 2 60010079 VALVE COUPLING INLET B 1 60010101 VALVE COUPLING OUTLET METER SIDE C 1 60010025 PLASTIC SECURE CLIP D 2 60010046 BYPASS SS CL...

Page 20: ...20 Control Valve Exploded View...

Page 21: ...2 A18 05056044 Adaptor Clip 2 A19 05056090 Screw ST4 2 13 Hexagon with Washer 2 A20 21709003 Secure Clip 2 A21 05056140 Valve Connector 1 A22 05056065 O ring 23 6 2 65 2 A23 21319006 Screw Adaptor 2...

Page 22: ...22 Power Head Exploded View...

Page 23: ...w ST2 9 10 5 B16 5056504 Bnt165 Pcb 1 B17 5056500 Bnt165 Front Cover 1 5056505 Bnt165 Operation Label 1 5056506 Bnt165 Regen Label 1 B18 5056509 Screw ST2 9 10 CSK 2 B19 5056082 Screw M3 5 2 B20 50565...

Page 24: ...a Increase Brine Time air draw b Check valve not working C Excessive pressure loss through filter 1 Filter bed overloaded with precipitated iron See problem above 2 Control inlet outlet valve s not fu...

Page 25: ...y part of this water conditioner as a result of misuse misapplication ne glect alteration accident installation or operation contrary to our printed instructions damage to ion exchange resin and seals...

Page 26: ...26...

Reviews: