background image

Page 17

h24Ap/hp uSEr mAnuAL EdItIon I 2013-02-20

Ersätter Dwg no.

A

8

7

5

3

2

19

17

9

22

6

22

18

14

4

16

1

20

6

24

A  (1 : 1)

10

15

21

13

12

11

22

23

Part no. 90280011

Pos.

Artikelnummer Part number

Ritningsnummer Drawing number

Description

Antal Qty

1

90270189

D054012

BASE HP/AP

1

2

90270248

D054013

HANDLE

2

3

90270295

S054028

Crimping head H24

1

4

90181371

Plastic cap

8

5

90270058

Enerpac turbo II

Pump H24AP, 250 bar

1

6

90270299

7204-06-08-hydroscand

Adapter 1/2"-3/8"

1

7

90270308

7022-06-06-hydroscand

G UFxNPT

1

8

90270309

Hydraulic hose 620

1

9

90010423

T0105

Rubber foot

4

10

90270044

Battery Holder

1

11

90270304

T053024

Push button

1

12

90270039

T053023

LED green

1

13

90270251

kopplingsdon part1

Stifttag G4A5M

1

14

90280006

S054026

Control device H24

1

15

90270813

D055041

Battery console

1

16

90175158

SC MC6S 8x40

8

17

90175020

Wa BRB M8

8

18

90175002

Wa BRB M6

6

19

90175031

NU LM6M M8 Locking

8

20

90175042

NU LM6M M6 Locking

2

21

90175312

SC MF6S M3x8

2

22

90175041

SC MC6S 6x16

10

23

90175294

SC MC6S 3x8

2

24

90180206

S061002

Die change tool

1

Drawn by

Approved by

Drawing size

Scale

Date

Part name

Drw. No.

PART LIST

QTY.

Rev. no.

Checked date

Revision information

Serial no.

Rev.

1:3

 

 

Material

 

 

  0

  

 

Dimension

Weight

 

 2014-04-23

NH

 

A2

 S054010_1

H24 AP

S054010

  For messures without    tolerances ISO 2768-m    is applied.   General surface finish    is: ra 3,2   Sharp edges broken.

Summary of Contents for H24AP

Page 1: ...USER MANUAL Edition I 2013 02 20 Serial number _________________ H24AP H24HP...

Page 2: ...lecting die set 8 4 3 setting crimping measurements 8 9 4 4 Changing die set 9 10 4 5 Changing die set with the QC tool 11 4 6 crimping 12 5 maintenance 12 13 5 1 lubrication 12 5 2 changing the oil 1...

Page 3: ...closest authorized supplier for a replacement manual or additional information if ne cessary This manual should be preserved and stored for the length of the machine s lifetime or at least ten 10 yea...

Page 4: ...the machine consists of a chassis crimping head and pump unit The machine is delivered ready to use packed in a wooden box on a pallet marked with serial number order number weight and volume Compare...

Page 5: ...oscand Machine AB Lost income or extra costs that may arise for any reason are not covered by the warranty Note Ensure that the machine is undamaged and that all of the described items are present upo...

Page 6: ...tured year Weight Voltage Pressure Force Always provide the following information and technical explanation of the machine s problem when contacting the authorized service workshop Model Serial number...

Page 7: ...andle 2 Carrying handle 3 Indicator lamp 4 Test button 5 Adjustment dial 6 On off valve 7 Battery compartment 8 Tank lid 9 Dies 10 Crimping head 1 Pump regulator on off 2 Carrying handle 3 Indicator l...

Page 8: ...ended Using dies that are too small risk the ferrule becoming oval 4 3 Setting crimping measurements Turn the adjustment dial so that the zero 0 on the dial is lined up with the zero 0 in the window I...

Page 9: ...in until the die releases 3 Make sure the 8 segment die set is clean undamaged and that all die seg ments are the same size with the die size markings facing towards you Insert the dies from the front...

Page 10: ...Page 10 h24Ap hp uSEr mAnuAL EdItIon I 2013 02 20 1 Locking pin 2 die 3 qc tool 3 2 1 1 die size marking 2 die set pin 3 qc tool 4 hole for qc tool 3 2 1 4...

Page 11: ...change tool in the contracted dies and then completely retract return the dies Insert the die set in its storage compartment QC rack or QC stand and turn the tool counter clockwise until it stops Rem...

Page 12: ...4 Check the crimped hose and make adjustments if necessary 5 Maintenance 5 1 Lubrication The machine should be cleaned and lubricated every eight 8 operation hours Retract the dies to lubricate Use a...

Page 13: ...inder 5 The hand pump is now ready to use 5 3 Changing the battery When the light indicator lamp becomes weaker then it is time to change the battery Open the lid and replace the battery Battery type...

Page 14: ...ements Low crimping force 1 Too little lubricant 2 Setting dial lost its position 1 Too little lubrication 2 Low oil level 3 On off valve not tightened enough 4 Leakage 5 Poor oil quality 6 Pump leaka...

Page 15: ...phase 3 phase 275 Bar Handpump Colour Black Orange DIMENSIONS H24AP Widht Depth Height 520x400x370 mm Weight 69 kg DESIGNATION PART NUMBER H24AP 9028 00 74 TECHNICAL DATA H24AP Crimping range in mm 1...

Page 16: ...3 8 1 12 90270299 7204 06 08 hydroscand Adapter 1 2 3 8 1 13 90270324 Handpump H24 1 14 90270309 Hydraulic hose 550 1 15 90270039 T053023 LED green 1 16 90270304 T053024 Push button 1 17 90270251 kopp...

Page 17: ...44 Battery Holder 1 11 90270304 T053024 Push button 1 12 90270039 T053023 LED green 1 13 90270251 kopplingsdon part1 Stifttag G4A5M 1 14 90280006 S054026 Control device H24 1 15 90270813 D055041 Batte...