OPERATION:

Startup Check List

ü

Check that all air tubing is connected to the injectors and any associated 

manifolds

ü

Check for pinched air injector lines

ü

Check for leaks, always

ü

Check power cord is connected to control 

ü

   Make sure the blower circuit voltage matches the blower voltage. 

1.  Fill the spa or bath with water.  Check for leaks   

2.  Connect the blower to the power source, either a spa controller or other 

device.  

3.  Do not connect blower to tub plumbing

4.  Activate the blower using the corresponding button on the control 

5.    Take an AMP reading with an AMP probe and make a note of this        
reading. 

6.  Turn off blower

7.  Connect the blower to the plumbing with the hose clamp provided

8.  Activate the blower using the corresponding button on the control

10.  With blower running take a reading with an AMP Probe.  The total AMP         
draw should not drop by more than ½ AMP

If the AMP draw drops by more than ½ AMP then the blower installed may 
be too large for the application.

**Operation of the blower should be limited to 20 minute cycles.  

Failure to follow this instruction will shorten the motor life** 

 

Startup:

Summary of Contents for Silent Aire Series

Page 1: ...Silent Aire Series High Performance Low Noise Air Blower TM Installation Owner s Manual...

Page 2: ...nvironment Indoor Use Only IMPORTANT Please provide these operating instructions to the end user All printed material should be read thoroughly prior to using the product These instructions are provid...

Page 3: ...ch of water pressure Example An 8 ft portable spa with a water depth of 38 inches with 6 feet of 1 5 supply line to the air manifold with 2 90 degree turns Calculation of total water pressure is as fo...

Page 4: ...T h e l i m i t e d w a r r a n t y d o e s n o t p r o v i d e c o v e r a g e w h e n used in a commercial installation APPLICATION BLOWER INSTALLATION PORTABLE SPAS New and Existing Installations C...

Page 5: ...plumbing 4 Activate the blower using the corresponding button on the control 5 Take an AMP reading with an AMP probe and make a note of this reading 6 Turn off blower 7 Connect the blower to the plumb...

Page 6: ...lent Aire blower has reached the end of its service life Blower will not operate Replacement Whispair blowers may be purchased from your Onga spa retailer or authorised Onga service dealer Blower star...

Page 7: ...efects in material and workmanship for a period of one year from the date of purchase HYDROQUIP will repair or replace the part if in our opinion the unit is defective This warranty excludes damage as...

Page 8: ...8 85 0021 REV 04 05 19 510A N Sheridan St Corona CA 92880 www hotwatercontrols com...

Reviews: