background image

11

Refer to Owner’s Manual for complete details

PuMP PRIMING MoDE

Flashing

Pump Icon(s)

  As  soon  as 

PRIMING  MODE

  is  indicated  

 

on the topside panel, push the left 

 pad  

 

to start Pump 1 in low speed, then again  

 

to  switch  to  high  speed.  Push  the  

 

center 

 pad and right 

 pad to start  

 

Pump  2  and  *Pump  3  respectively  

 

(*Titanium  Series  only).  These  are  both  

 

single speed - high only. All of the pumps 

will now be operating in high speed to facilitate priming. 

See  FILLING,  CHECKING  AND  STARTING  YOUR  HOT  TUB  for 

complete instructions on pump priming.

Once pump priming has been successfully completed, press 

the 

  pads to turn off the pumps. Next, manually exit 

PRImING  mODE  by  pressing  either  the 

  pad  or  the 

 pad. If you do not manually exit Priming mode, it will  

automatically terminate after 4 to 5 minutes. Be sure that 

the pumps have been primed before exiting this mode.

TEMPERATuRE CoNTRoL 

FuNCTIoNALITY AND ADJuSTMENT  

After you manually exit or the system automatically exits 

PRImING  mODE,  your  hot  tub  will  automatically  heat  to 

the factory preset default temperature of 38˚C (100˚F). The 

topside panel will briefly show the default temperature, and 

then the display will appear as follows:

Flashing

Pump 1 Low Speed Icon

  Note  that  the  water  temperature  is  not  

 

yet  displayed,  as  the  system  requires  

 

approximately  2  minutes  of  water  flow  

 

through  the  heater  to  determine  

 

temperature. This is referred to as ‘polling’  

 

and  is  indicated  on  the  display  by  the  

 

  icon.  After  2  minutes  the  display  

 

will  show  the  current  measured  water  

 

temperature.

 

Press  the 

  pad  to  increase  the  

 

temperature  to  the  desired  setting.  The  

 

  icon  will  appear  on  the  display 

 

indicating  that  the  heater  has  been  

 

activated.

In  Standard  Operating  mode,  the  system  automatically  

activates  Pump  1  low  speed  every  30  minutes  for 

at  least  2  minutes.  After  2  minutes,  the  spa  water  

temperature  is  determined.  At  this  point,  if  the  water 

temperature  is  lower  than  the  set  temperature,  P1  will  

continue  to  run  and  the 

  icon  will  appear  on  the  

display. The heater will operate until the water temperature 

reaches  the  set  temperature  point,  after  which,  both  the 

heater and Pump 1 low will automatically turn off.

hyDropool Self clean SerieS control SyStemS

europe/north america

HYDRoPooL SELF CLEAN – PLATINuM & LuxuRY EDITIoN 

INITIAL START-uP

Before applying voltage to power-up your hot tub, it is very 

important that you understand the sequence of events that 

occur when the system is activated in order that the pumps 

can be primed efficiently and damage to the pumps can be 

avoided.

  At initial power-up, this display will appear,  

 

and  the  system  will  show  4  sets  of  

 

numbers  in  succession  (ie.  100  then  114  

 

then  28  then  240).  These  numbers  

 

represent  the  current  software  revision, 

and the system input voltage.

Flashing

  After  the  initial  software  indicators  are  

 

shown, this display will appear. This display  

 

is indicating that the system is in PUmP  

 

PRImING  mODE.  This  mode  will  last  for  

 

4  to  5  minutes  before  automatically  

 

exiting  and  entering  the  normal  

operation  mode.  You  can  also  manually  exit  the  PUmP 

PRImING mODE after the pumps are primed. 

While  in  this  mode,  the  heater  circuit  is  disabled  to  

allow  the  priming  process  to  be  completed  without 

the  possibility  of  energizing  the  heater  element  during  

low  flow  or  no  flow  conditions.  The  system  will  not  

automatically  activate  any  of  the  functions,  however,  by 

pushing the 

 pads on the topside control, the pumps 

can be manually activated to facilitate priming.

Definition: 

‘Priming’ a pump is a term used to describe the  

process  in  which  air  trapped  in  the  plumbing  and  pump 

wet-end  (referred  to  as  an  ‘air  lock‘)  is  released,  allowing 

the  pump  to  move  water  efficiently  through  the  plumbing 

system and to the jets. 

Platinum

Luxury Edition

Flashing

Pump 1 Low speed Icon

Summary of Contents for Gold Series 20A

Page 1: ...self cleaning hot tubs Quick Start Guide For complete instructions please refer to the Owner s Manual on CD Hydropool Inc Tel 905 565 6810 Toll Free 1 800 465 2933 Fax 905 565 6820 Email info hydropoo...

Page 2: ...Ground Fault Circuit Interrupter monthly 16 Post emergency phone numbers for Police Fire Dept and Ambulance at the nearest phone 17 Maintain water chemistry balance in accordance with manufacturer s...

Page 3: ...partment To reduce the risk of electric shock connect the local common bonding grid in the area of the hot tub to these terminals with an insulated or bare copper conductor not smaller than No 6 AWG C...

Page 4: ...t n i e h T l a r t u e N l a r t u e n s i h t s e r i u q e r I C F G e h t k r o w t o n l l i w I C F G e h T n o i t c e n n o c t i t u o h t i w m o r F c i r t c e l E e c i v r e S l e n a P...

Page 5: ...l water starts to flow Turn the main power on at your electrical panel Follow the control instructions for your particular model hot tub to put the pump into low speed P 5 10 Check that the jets are f...

Page 6: ...l To Hot Tub Support Equipment Important Note Installation of the R C D Circuit Breaker including ampere sizing and selection of conductor size and type must be performed by a qualified electrician in...

Page 7: ...th care and store in a cool dark place Never smoke near chemicals as most are flammable Always have the Poison Control telephone number handy in the event of an emergency Keep chemicals out of childre...

Page 8: ...e the cartridge filter back into the filter housing 12 Replace the filter housing lid pushing it down to seat ensuring that the lid o ring does not become twisted 13 Hydropool recomends that the lid o...

Page 9: ...ent water temperature then press the pad again The temperature can be adjusted from 21 C 70 F to 40 C 104 F in 1 increments HEater Function The heater operates with pump low speed only and turns off w...

Page 10: ...system automatically activates the blower for 30 seconds at the beginning of each filter cycle to introduce fresh sanitized water into the blower plumbing circuit MODE FUNCTION A combination of keypa...

Page 11: ...ast 2 minutes After 2 minutes the spa water temperature is determined At this point if the water temperature is lower than the set temperature P1 will continue to run and the icon will appear on the d...

Page 12: ...3 icon spins fast 2nd press turns off pump no icon displayed when P3 is off PUMPS AUTOMATIC TIME OUT P1 high speed P2 P3 15 minutes P1 low speed 4 hours Pump Blower operating conditions Platinum Serie...

Page 13: ...ve Press to enter and to proceed At this point PROGRAM FILTER2 and ENDTIME will appear on the display Adjust time as above Press the pad again to enter the filter cycle times into the system and exit...

Page 14: ...rain assist feature stops the system from operating automatically allowing for convenient filter cartridge removal and for safe draining of the hot tub The following pads must be pressed within 3 seco...

Page 15: ...nterior surface 11 To completely flush the old water from the plumbing lines allow fresh water to fill into the foot well area while the old water continues to be pumped out Always keep at least 10cm...

Page 16: ...16 Refer to Owner s Manual for complete details NOTES...