![Hydronix Hydro-Probe XT User Manual Download Page 25](http://html.mh-extra.com/html/hydronix/hydro-probe-xt/hydro-probe-xt_user-manual_2192332025.webp)
Hydro-Probe XT User Guide HD0538 Rev: 1.6.0 25
Hydro-Probe
Extension
Mounting sleeve
Bin wall
Figure 17: Hydro-Probe installed in an Extension Mounting Sleeve
4.3
Drip Loop
Some corrosion is possible if the moisture run off from the material reaches the connector.
This will be increased if the moisture is allowed to run along the sensor cable and collect at
the connector. This can be reduced by installing the cable with a drip loop. This will cause the
moisture to drip off of the cable before it reaches the connector. See Figure 18
Hydro-Probe
Bin wall
Drip Loop
Mounting Sleeve
Figure 18: Hydro-Probe installed with a drip loop
4.4
Protection cover
Install a cover over the top of the sensor to deflect the material away from the connector. See
Material
Protection cover
Hydro-Probe
Figure 19: Deflector plate
Summary of Contents for Hydro-Probe XT
Page 4: ...4 Hydro Probe XT User Guide HD0538 Rev 1 6 0 ...
Page 6: ...6 Hydro Probe XT User Guide HD0538 Rev 1 6 0 ...
Page 8: ...8 Hydro Probe XT User Guide HD0538 Rev 1 6 0 ...
Page 10: ...10 Hydro Probe XT User Guide HD0538 Rev 1 6 0 ...
Page 14: ...Chapter 1 Introduction 14 Hydro Probe XT User Guide HD0538 Rev 1 6 0 ...
Page 42: ...Chapter 4 Configuration 42 Hydro Probe XT User Guide HD0538 Rev 1 6 0 ...
Page 58: ...Chapter 7 Sensor diagnostics 58 Hydro Probe XT User Guide HD0538 Rev 1 6 0 ...
Page 60: ...Chapter 8 Technical specification 60 Hydro Probe XT User Guide HD0538 Rev 1 6 0 ...
Page 66: ...Appendix B Document Cross Reference 66 Hydro Probe XT User Guide HD0538 Rev 1 6 0 ...